Failures
Walter Finkbeiner GmbH
Alte Poststrasse 9/11
72250 Freudenstadt / Germany
www.finkbeiner.eu
36 / 56
PB-BA-EHB702-102GB
22.02.2011
9.3.2 Fault repair on the defective column
DANGER
Danger to life by electrocution.
•
The components within the control box are live wired, if main switch is activated.
Master
Plug-in the grey interconnect cable of the master column into it’s own socket.
Check the power supply (fuses at user’s side).
Check fuses inside control box of master column.
•
Green LED on circuit board should be on, if not replace fuse.
•
Yellow LED on circuit board should be on, if not replace fuse.
•
Fuses of transformer.
Check connections inside of plugs / sockets as well as the interconnect cable for contact or dam-
age.
Replace slave circuit board (identical in all columns).
Replace master circuit board
Check the roller limit switches and switch cam
see chapter “check of limit cycle switches and
switch cam“.
Slave
Connect the defective slave column with the master, the cable circuit needs to be closed.
Replace the slave board by a slave board from an operative slave column.
If slave column is operative now: slave board defective, to be replaced.
Check connections inside of plugs / sockets as well as the interconnect cable for contact or dam-
age.
Check the roller limit switches and switch cam
see chapter “check of limit cycle switches and
switch cam“.