13
M16MI316_A08_07/21
Jarua
Installation and maintenance of your towel rail
3. CONNECTION
The electrical installation must comply with local or
national regulations. This appliance must be installed by
a competent electrician.
3.1 Electrical connection
• The technical characteristics of your appliance are shown
on the data plate located on the side of the appliance.
Please take note of these before any request for after
sales service.
• Any interventions on electrical parts must be done by a
qualified professional.
• For bathroom installations the appliance must be installed
outside zone 1 with the electrical connection outside zone
2 (see diagram at the opposite page), in accordance with
the latest electrical safety regulations, and in such a way
that the controls cannot be reached by a person using the
bath or shower,
• Enclosure class IP44,
• Connect the 3 core cables as follows:
Brown wire = Live • Blue wire = Neutral
Black wire = Control Wire (Pilot Wire)
This wire must never be connected to the earth
and must be isolated,
• RCD of 30 mA maximum is compulsary for bathrooms or
shower rooms,
• This appliance must be connected to the fixed wiring
through a cable outlet (13 A max) and controlled through a
double pole switch having a contact separation of at least
3 mm in all poles,
• The radiator is supplied with a 1.5 m cord,
• Supply voltage 230-240 V,
• For installation in a bathroom (to comply with current IEE
regulations) the appliance must be wired in the manner
prescribed with the double pole switch mounted outside
the bathroom. If the supply cord on this product is
damaged, it must be replaced by the manufacturer, its
service agent, or other qualified person. This radiator is
filled with a precise quantity of liquid, any repairs that
involve opening the radiator must be carried out by the
manufacturer or his service agent. Any leakage must be
dealt with by the manufacturer or his representative.
• The factory fitted power cable must be connected to the
mains by a junction box which will have to be placed
behind the appliance, without putting in a power socket
and which will be located at least 250 mm from the floor.
• If the supply cable is damaged, it must be replaced by a
specific cable. Replacement of this cable must be done by
the manufacturer, their after sales service or people with
similar qualifications in order to avoid any danger.
• The heated towel rail is filled with an exact quantity of
heat transfer fluid. Repairs requiring opening of the
bathroom heater must only be carried out by the
manufacturer or their after sales service who must be
contacted if there is any leak of heat transfer fluid.
• When the appliance is thrown away, elimination of the
heat transfer fluid must only done by approved
subcontractors.
3.2 Central Heating connection - mixed version
appliances
• This appliance intended for central heating installation is
delivered empty (without any heat transfer fluid).
• Connection to the central heating is done either through
2 tapped holes ½” (Ø15/21), or through a 4 way valve with
probe. Ensure that the appliance is always in
communication with the expansion tank (both summer
and winter) and correctly filled with water (by purging the
air from the radiator) before turning on the electric part.
• Note the indicated flow direction.
When operated electrically, the radiator’s outlet valve
must be closed; the return must be in «open» position so
that the radiator remains in communication with the
installation in order to absorb fluid expansion.
Depending on the central heating, the outlet and return
valves must be open and the appliance switched off.
Switching on the appliance without it being correctly filled
with water renders the guarantee null and void
(deterioration of heating element).
4. CONDITIONS OF USE
Refer to the paragraph WARNINGS in point
1. GENERAL INFORMATION
• The heater can be used continuously without any risk.
• For operating the electronic regulation refer to the
operating instructions.
5. MAINTENANCE TIPS
Maintenance operations must be done with the heater
switched off. Therefore take care the appliance is off. In
order to ensure your heater lasts, we recommend you use
the following few tips:
• Use only mild cleaning agents when cleaning and wiping
of the radiator is necessary.
• Use a dry cloth (without solvent) for the control unit.
• Use warm soapy water for cleaning the outside walls of
the heater (no abrasive or corrosive product).
• This heating appliance is filled with an exact quantity of
heat transfer fluid, or glycoled water depending on
appliances. Repairs requiring opening of the reservoir
must only be carried out by the manufacturer or their
after sales service who must be contacted if there is any
leak of glycoled water. This fluid, specially developed for
this use does not require any particular maintenance.
E