SAFETY INDICATIONS

WHAT TO DO:

Make sure that mains voltage corresponds to the voltage indicated on CE plate and that cable of suitable cross-section are

used for electric connections.

Always check oil level  before starting the compressor.

Be familiar with emergency stop control  and all other controls.

Empty the air tank and/or  oil separator and unplug the connector before any maintenance work, so to avoid accidental start.

Ensure that all parts have been correctly reassembled after any maintenance work.

Keep children and animals off the working area  to avoid injuries caused by devices connected to the compressor.

Carefully read instructions for the installed accessory, especially if painting devices are installed.

Ensure  that the installation place is properly ventilated.

Ensure  that temperature of the working environment ranges b5 and + 45 ºC.

The compressor should be installed and operated in a non-explosive environment.

Allow at least 50 cm  between the compressor and the wall so to allow free air flow to the fan.

Press the emergency button on the control panel only in case of actual need so as to avoid possible damages to people or the

very compressor.

When calling for technical assistance and/or advice, always mention model and serial number indicated on CE plate.

Always follow the maintenance schedule specified in the user’s guide.

WHAT NOT TO DO:

Do not touch inner parts and pipes as they are very hot during compressor operation and stay hot  for a certain time after

compressor stop.

Do not position  inflammable or nylon objects or cloths close to and onto the compressor.

Do not  move  the compressor when the tank is under pressure.

Do not operate  the  compressor if the power cable is damaged or defective or if connection is unstable.

Do not operate  the compressor in explosive environment or in case of naked flames.

Do not operate the compressor in wet or dusty environments.

Never aim    the air jet at people or animals.

Do not allow unauthorized people to operate the compressor and give them all required instructions.

Do not hit fans with blunt objects as they might break during compressor operation.

Never operate the compressor without air filter.

Do not tamper with  safety and adjusting devices.

Never operate the compressor when doors/panels are open or removed.

PRODUCT IDENTIFICATION

The compressor Your have purchased has its own CE plate showing the following data:

1)  Manufacturer’s data

2)  CE mark – year of manufacture

3)  TYPE = name of the compressor

     CODE = compressor code

     SERIAL NO. = serial number of the compressor You have purchased (to be always mentioned when calling for technical

assistance)

4)  air delivered by the compressor expressed in (l/min) and (cfm)

5)  max. operating pressure (bar and PSI) – compressor noise level in dB(A)

6)  electric data: voltage (V/ph), frequency (Hz), absorption (A) - power (HP and kW), rotations per minute (Rpm).

7)  other approvals

Содержание ROTAR PLUS 20

Страница 1: ...facturers f Products can be delivered to the Manufacturer for servicing purposes only after prior authorization by the very Manufacturer The Manufacturer shall decide at their discretion whether authorization can be granted or require an Authorized Service Center to take on servicing In any case products shall be delivered free of any charge and will be returned to the Customer on ex factory basis...

Страница 2: ...and maintenance carried out so far SYMBOLS USED IN THE MANUAL Some symbols are used to highlight danger situations give recommendations or information These symbols are usually positioned next to the text a figure or at the top of a page in this case they refer to all subjects dealt with in that page Carefully read symbol meaning below CAUTION Important description on service dangerous situation s...

Страница 3: ...the maintenance schedule specified in the user s guide WHAT NOT TO DO Do not touch inner parts and pipes as they are very hot during compressor operation and stay hot for a certain time after compressor stop Do not position inflammable or nylon objects or cloths close to and onto the compressor Do not move the compressor when the tank is under pressure Do not operate the compressor if the power ca...

Страница 4: ...llection centres for disposal PLACEMENT AND INSTALLATION fig 2 Upon installation make sure that the chosen place is in compliance with all prevailing national safety standards and meets the following requirements low percentage of dust suspended in air shop must be suitably sized and well ventilated so that room tem perature never exceeds 40 C when the compressor is working If this is not the case...

Страница 5: ...24 50 60 Electrical box protection class IP 54 54 54 54 54 54 Motor insulation class F F F F F F Full load current A 31 31 31 36 36 36 Starting load A 70 75 73 98 104 107 Max Start up per hour n 10 10 10 10 10 10 Ambient limit temperature C 50 50 50 50 50 50 Noise level at 1 m Cagi pneurop dB A 70 70 70 71 71 70 3URWHFWLRQ GHYLFHV Max compressor temperature C 110 110 110 110 110 110 Min oil temper...

Страница 6: ...led loadless cycle starts blinking LOADLESS message is displayed once loadless cycle is over compressor stops and off message is displayed 8 Emergency stop switch to stop compressor only in case of actual need 9 Functioning diagram maintenance operations WORKING TIMES Automatic mode The compressor operation is controlled by the pressure transducer which stops the machine when the max pressure valu...

Страница 7: ...ission using RS485 and automatically disable transmission on RS232 12 Pressure sensor service password enables the 4 20 mA input to which the pressure sensor is connected With this parameter activated the pressure measurement is displayed To display machine operation time press the key the display will revert to the pressure measurement automatically after 20 seconds Enabling this parameter the ex...

Страница 8: ...t be silenced by the service technician who when carrying out maintenance operations will select the item Pre alarm hours from the menu and reset the value as described under the heading Modifiable parameters point 1 9 Separator pressure switch Alarm trips in the event of the separator pressure switch contact opening The compressor locks up To silence the alarm first reset the separator pressure s...

Страница 9: ...l mixture which ensures the seal and the lubrication of the moving parts of the compressor The air oil mixture returns to the tank 6 where the air is pre separated through spinning and is finally separated from the oil by the oil separator filter 13 From the tank 6 only air comes out which reaches the radiator 11 through the tube 15 and the mains through the cut off cock 16 FIRST START UP Before s...

Страница 10: ...ey would let dust into the compression unit Replace the air filter when you have cleaned it four times Clean the radiators The radiator is highly efficient with a limited clogging degree However in case of abnormal overheating or at least once a year a check for filter clogging is recommended To clean the radiators proceed as follows remove the rear and upper panels of the pressurized chamber posi...

Страница 11: ...ion rules in force EVERY 2000 OPERATING HOURS Check drive belt tension Fig 12 Use a frequency tester to carry out this check Proceed as follows Move tester microphone closer to the belt about at mid length and hit the belt with a wrench Read value on tester Stretch or slacken the belt if the value is different from values indicated in the table Higher value slacken Lower value stretch To adjust pr...

Страница 12: ... Change the drive belt as follows fig 12 2 Tighten the screw 1 turning it clockwise with a hexagon head wrench until you feel that the belt is slackening and comes off easily 3 Install the new belt and set the screw 1 back to its original position turn clockwise Leave belt slightly slack Check frequency value as described on page 11 1 Test 12 ...

Страница 13: ...ignal Oil separator filter clogged Min pressure valve does not clo se perfectly Voltage too low Shop too cold Leakage from tubes Leakage from front compressor flange Remedy Check voltage press Reset and start once again Check motor absorption and check relay settings If absorption is OK press Reset and start once again Check oil drainage tube and non return valve Check oil level and drain some if ...

Страница 14: ... 500 mA 500V KM1 Line contactor 18 5 kW 11 kW 18 5 kW 11 kW KM2 Delta contactor 18 5 kW 11 kW 18 5 kW 11 kW KM3 Star contactor 15 kW 7 5 kW 15 kW 7 5 kW FR Thermal relay 28 40 17 22 28 40 20 25 YV Solenoid valve SP1 Minimum pressure switch SP2 Pressure switch for oil separator filter SP3 Pressure switch for air filter BP Pressure transducer 0 16 bar D Electronic controller ST Thermal feeler for el...

Отзывы: