background image

A SLEEK ACCESS

The k-Kadex is the latest slave terminal from FingerTec, 
designed exclusively for card and code access. The k-
Kadex  reads  and  records  user’s  information  such  as 
users  ID,  password  and  card  information  and  directly 
transmits  the  information  to  a  master  terminal  for 

verification via Wiegand 26-bit output. It is compulsory 
for the master terminal to have a Wiegand 26-bit input 

port to receive signals from the k-Kadex. 

1

2

3

4

5

6

7

8

9

ESC

0

OK

k-Kadex

Rear of k-Kadex Terminal

Rear of Master Terminal

Red

Black

White

Green

Purple

Grey

Blue

Yellow

PWR

GND

WD0

WD1

BEEP

G LED

Bell +

Bell -

PWR

GND

INWD0

INWD1

BEEP

G LED

PWR

GND

External Power Supply

External

door bell

+

_

Power supply 

for door bell

+

_

External doorbell system 

*The doorbell is optional 

LED light indicator
The red light indicates standby mode or failed verifica

-

tion. The green light indicates that the card information 

is  being  read  and  sent  to  the  master  terminal  for 
verification.

Card scanning area
To scan and receive card information for verification at 
the master reader.  Default card type: RFID Card, 125kHz 
40  to  80mm.  Made  to  order:  MIFARE,  13.56MHz  30  to 
50mm 

Installation

Note: 

Please read the instructions carefully before installing the k-Kadex. 

The  k-Kadex  has  one  wire  attached  to  it.  For  a  neat 
installation, you need to conceal this wire properly. 

Remove the back piece of the k-Kadex from the main 

piece.

Secure the back piece of the k-Kadex onto or inside a 
wall using the 4 screws provided but make sure that 

you have some space for the wire to go through the 
center  hole.  Plug  the  main  piece  of  the  k-Kadex 
securely in place. 

Note: 

There are 2 small hooks inside the back piece. Make sure this portion 

is facing up. 

Verification

User ID & Password

Make  sure  that  the  k-Kadex  is  in  its  standby  mode, 
where the LED light blinks red and the user ID and/or 
password(s) have been enrolled into a master terminal 
before you proceed with verification.
Insert  a  user  ID,  for  example  1234.  Ignore  the  prefix 
zeros if the user ID has them. Press OK to confirm the 
user ID You will hear a beep. This is an indication that 
the User ID has been sent to the master terminal. 

LED light 

indicator

Card 

scanning 

area

Door

bell 

button

Color

Red
Black

White

Green

Purple
Grey
Blue
Yellow

Wire

PWR

GND

WD0
WD1

Beep
G LED
Bell +
Bell - 

Connect to 

master

PWR

GND

INWD0
INWD1

BEEP
G LED

Function

Supplies power (DC12V 1A) to 

k-Kadex

Wiegand 26-bit output connects to 
a master terminal’s. Wiegand 26-bit 

input

Buzzer input from the master terminal

LED input from the master terminal

Dry contact to doorbell system (the doorbell system must 

have an individual power supply)

Connections & Wiring Diagram

Note:

 

There is only 1 black wire provided which can be shared for the GND for power supply and 

Wiegand 26-bit output.

1

2

1

2

1

2

w w w . f i n g e r t e c . c o m

w w w . f i n g e r t e c . c o m

User Guide

A SLEEK ACCESS

The  k-Kadex  is  the  latest  slave  terminal  from  FingerTec,  designed  exclusively  for  card  and 
password access. The k-Kadex reads and records users’ information such as users ID, password 

and card information and directly transmits the information to a master terminal for verification 
via Wiegand 26-bit output. It is compulsory for the master terminal to have a Wiegand 26-bit 

input port to receive signals from the k-Kadex. 

Rear of k-Kadex Terminal

Rear of Master Terminal

PWR

GND

WD0

WD1

G LED

R LED

Bell +

Bell -

PWR

GND

INWD0

INWD1

BEEP

G LED

R LED

PWR

GND

External Power Supply

External

door bell

+

_

Power supply 

for door bell

+

_

External doorbell system 

*The doorbell is optional 

Card scanning area

To scan and receive card 

information for verification at 

the master reader.  Default card 

type: RFID Card, 125kHz 40 to 

80mm. Made to order: MIFARE, 

13.56MHz 30 to 50mm

Door bell button

Color

Red
Black
Green

White

Purple
Grey
Blue
Yellow

Wire

PWR

GND

WD0
WD1

G LED
R LED
Bell +
Bell - 

Connect to master

PWR

GND

INWD0
INWD1

G LED
R LED

Connections & 

Wiring Diagram

Note:

 

There  is  only  1  black  wire  provided 

which  can  be  shared  for  the  GND  for  power 
supply and Wiegand 26-bit output.

LED light indicator

The red light indicates standby 

mode or failed verification. The 

green light indicates that the 

card information is being read 

and sent to the master terminal 

for verification.

A Firm Access with 

FingerTec 

k-Kadex

©

2015 Timetec Computing Sdn Bhd. All rights reserved • 082015

1

2

Red

Black

Green

White

Purple

Grey

Blue

Yellow

Red

Black

Green

White

Grey

Blue

Function

Supplies power (DC12V 1A) to k-Kadex

 

Wiegand 26-bit output connects to a master 
terminal’s Wiegand 26-bits input

Buzzer with Green LED input from the master terminal

Buzzer with Red LED input from the master terminal

Dry contact to doorbell system (the doorbell system must have an 

individual power supply.

Отзывы: