background image

WelcomeCheck-In

01-01 09:00 

Sun

[email protected]

R2

1

2

3

4

5

6

7

8
0

9

ESC

OK

MENU

w

12-01-01  SUN

[email protected]

H2i

[email protected]

Q2i

[email protected]

WelcomeCheck-In

01-01 09:00 

Sun

[email protected]

R2

1

2

3

4

5

6

7

8
0

9

ESC

OK

MENU

w

12-01-01  SUN

[email protected]

H2i

[email protected]

Q2i

[email protected]

WelcomeCheck-In

01-01 09:00 

Sun

[email protected]

R2

1

2

3

4

5

6

7

8
0

9

ESC

OK

MENU

w

12-01-01  SUN

[email protected]

H2i

[email protected]

Q2i

[email protected]

WelcomeCheck-In

01-01 09:00 

Sun

[email protected]

R2

1

2

3

4

5

6

7

8
0

9

ESC

OK

MENU

w

12-01-01  SUN

[email protected]

H2i

[email protected]

Q2i

[email protected]

WelcomeCheck-In

01-01 09:00 

Sun

[email protected]

R2

1

2

3

4

5

6

7

8
0

9

ESC

OK

MENU

w

12-01-01  SUN

[email protected]

H2i

[email protected]

Q2i

[email protected]

 

Qi 

AC900 

Kadex 

m-Kadex

  Hi 

Face ID  

Face ID           i-Kiosk 100 Plus

Step

 

1

 

Look  for  the  power  input  port  on 

the  FingerTec  terminal.  Normally  the  con-

nection ports on the terminals are marked as 

PWR/+1V (

red wire

) and GND (black wire).

Step

 

2

 

Convenient  Installation:  Look  for  the  door 

lock  output  port  NO  and  GND  from  the 

terminal.Secure  Installation:  Look  for  the 

Wiegand  output  port,  WDO  (green),  WD1 
(white) and GND (black) from the terminal.

Step

 

3

 

Connect  the  wires  from  the  terminals  to 

AdapTec Plus. 

Convenient  Installation:  See  diagram  1,  page  8  for 

details. Secure Installation: See diagram 2, page 8 for 
details.

Step 

4

 

Connect the wires from AdapTec-X 

to the door lock system. 

(See diagram 1, page 8 

for details). (Ignore this if you only want to use the sys-

tem for time attendance purposes)

Step 

5

 

Connect  AdapTec-X  to  a  1VDC 

rechargeable  backup  battery. 

(See  diagram  1, 

page 8 for details). (This is optional. Ignore this if you 

do not need any backup power).

Step

 

6

   

Connect  AdapTec-X  to  a  power 

source (1VDC A).  

deTAiLs oF wiring

AdapTec-X supports  types of installations, Convenient or Secure. You can select between 

modes  by  applying  different  wiring  arrangements  during  installation.  Under  Convenient 

mode,  AdapTec-X  will  unlock  doors  immediately  after  receiving  responses  from  FingerTec 

devices. This feature is supported by all FingerTec models.
For installations using Secure mode, there will be a 1s time delay when unlocking the door 

after verification at FingerTec devices. This delay is due to the 6-bit Wiegand transmission of 

encrypted password from device to AdapTec-X. This is an optional security feature provided 

by AdapTec-X for users who favor more security (slight delay) over convenience (no delays).
AdapTec-X works with FingerTec terminals via an encrypted Wiegand signal to control the 

door open-close mechanism. Please make sure you are using the following FingerTec models 

that  support  the  encrypted  6-bit  Wiegand  signal  to  work  with  the  AdapTec-X  to  setup  a 

door lock system:

Содержание AdapTec-X

Страница 1: ...Installer Guide...

Страница 2: ...ill only recognize encrypted Wiegand signals from FingerTec terminals in order to un lock its doors The code of the encrypted signals is written into the firmware of FingerTec terminals which cannot b...

Страница 3: ...of short circuiting when using AdapTec X Control IN OUT Terminals at an Entrance AdapTec X is a perfect choice for an IN OUT installation where a door is controlled both at the entrance and the exit S...

Страница 4: ...Over input voltage Yes 3 long beeps Door release Yes 2 short beeps Door forced open Yes continuous beeps May opt to output external siren system Illegal dismantling of Yes continuous beeps May opt to...

Страница 5: ...geable backup battery During a power failure the backup battery will power up AdapTec X 3 These are the power output ports for AdapTec X Refer to the wiring diagram for details 4 These are the Wiegand...

Страница 6: ...e consult support fingertec com 2 Adjust the door lock timer for a longer or shorter unlocking time period by turn ing the screw clockwise Count the LED blinks after turning it Each blink repre sents...

Страница 7: ...onnect the wires from the terminals to AdapTec Plus Convenient Installation See diagram 1 page 8 for details Secure Installation See diagram 2 page 8 for details Step 4 Connect the wires from AdapTec...

Страница 8: ...Emergency 2 Break Glass 3 ON OFF C Key Switch D AdapTec X Connection Points GND WD1 WD0 Connection Points Exit Button Regulated Battery Tamper Siren EM 12 OV Siren Exit OV Data Input SW Out Lock Out...

Страница 9: ...Points GND WD1 WD0 Connection Points Regulated Battery Tamper Siren EM 12 OV Siren Exit OV Data Input SW Out Lock Out Mute SW 0V 14 5V 0V 12V D1 D0 GND 12V 12V GND COM NO Contactless Exit Button 12V...

Страница 10: ...w ever no alarm sound will be emitted if the terminal is not equipped with an external siren To use the siren feature we recommend that you install an ad ditional alarm siren and connect it to the Fin...

Страница 11: ...12V COM2 NO2 Alarm Siren WIRING DIAGRAMS 4 Alarm siren Face ID 2 Q2i and i Kiosk 100 Plus Deactivating the Alarm Siren 1 At the terminal press Menu and select Turn Off Alarm to turn off the alarm sir...

Страница 12: ...door strike instead Please consult a qualified technician installer before proceeding with the installation 1 To install FingerTec AC900 R2 on a wall drill 5 holes as shown 4 small holes are for the...

Страница 13: ...sition Glass Door 1 Lodge the U Bracket into the upper edge of the glass doorframe Tighten the 4 Allen Key Screws to hold the U Bracket into position 2 Place the Steel Bar on the side of the U Bracket...

Страница 14: ...EM Lock PC OVERVIEW OF THE WHOLE SYSTEM INSTALLATION 1 Drill 4 holes on the wooden frame Tighten the 4 screws to fix the Aluminum Plate properly on the doorframe 2 Use the Allen Key to tighten the 2 s...

Страница 15: ...ard AdapTec X Emergency Break Glass EM 600 EM 1200 ON OFF Keyswitch Release Button Contactless Release Button Alarm Siren with Strobe Light mounting an adaptec x onto a wall fingertec accessories For...

Страница 16: ...2018 Timetec Computing Sdn Bhd All rights reserved Printed in Malaysia 072018 NOTE Details in this manual are subject to change Check http product fingertec com for latest product information...

Отзывы: