7
AdapTec AC
Access Control/Power Output Module
Siren
Tamper
Siren Relay
12V
EM Accept Output Switch EXT.
Door
To
Battery
Accept
OK 12V MAX
0.5A Voltage
Input
I/P Exit
0 0
0 12V 0
12V
C NC
12V
0
- +
R
Red
B
Blue
G
Green
L
N
E
-V
+V
Power Supply/Power Input Module
AC110~240V
L - Live
N - Neutral
E - Earth
NC2
COM2
NO2
NC1
COM1
NO1
BUT
GND
SEN
EM +
Lock -
Emergency 2
Break
Glass (NC) 3
ON-OFF C
Key Switch
(NC) D
Release
Button
485B
485A
GND
232T
232R
GND
WD1
WD0
RJ45-1
RJ45-2
RJ45-3
RJ45-6
BELL+
BELL-
BEEP
GLED
RLED
INWD0
INWD1
GND
+12V
R
B
G
WIRING DIAGRAMS
R2/M2, i-Kiosk100, i-Kiosk100 Plus, Q2i and Kadex
ACCESS CONTROL ONLY OR TIME ATTENDANCE &
DOOR ACCESS
STEP 1 •
Connection Points
STEP 2 •
Connect AdapTec AC to a Power Source
STEP 3 •
Turn on the power to use the model for door access control
only or for time attendance and door access control simultaneously.