Fine Offset Electronics WH1081PC Скачать руководство пользователя страница 5

 

- 5 - 

 

 

Important Notes: 
 

On the edge of wind direction sensor, there are four alphabet letter of “N”,”E”,”S” and “W” representing for the 
direction of North, East, South and West. Wind direction sensor has to be adjusted so that the directions on 
the sensor are matching with your real location. Permanent wind direction error will be introduced when the 
wind direction sensor is not positioned correctly during installation. 
 
Wind speed sensor wire has to be inserted into the phone jacket on wind direction sensor. 
 
Wind direction sensor wire has to be inserted into the phone jacket located on the thermo-hygro sensor with 
marking of “Wind” on top. 
 
The rain sensor wire has to be inserted into the phone jacket located on the thermo-hygro sensor with 
marking of “Rain” on top. 

 
System Start 
 

Insert two pieces of LR6 (AA size) batteries into the transmitter, the LED located in the middle front case of 
transmitter will be turned on for 4 seconds, then it will be off and start to work normally. The transmitter will 
make a data transmission. When there is a data transmission happened, the LED will be on for 20ms.   

   

After inserting the batteries into the Weather Station, all LCD segments will be turned on for a few seconds, 
all possible display segments are turned on for checking.         
   
After this, the weather station will make initial measurement and start to register the transmitter. Before there 
is outdoor data received, it is not allowed to touch the LCD, otherwise the outdoor sensor learning mode will 
be terminated right after the touch of LCD. When outdoor transmitter has been registered, the Touch Screen 
Weather Station will automatically switch to the normal display mode from which all further settings can be 
performed by the user.     
   
   

Positioning 

 

Once you have verified that all of the components of the weather station are working, they can be positioned 
in their permanent places.    Before permanently mounting, make sure that all components work properly 
together at their chosen mounting or standing locations.     
   

Содержание WH1081PC

Страница 1: ...ure is a combination of the absolute air pressure and the altitude ABSOLUTE AIR PRESSURE Absolute air pressure is the actual air pressure on the barometer without regard to altitude INCHES OF MERCURY...

Страница 2: ...y slightly touching not pressing the related areas touch the flashing ON OFF or to make the corresponding selection or increase the value Every time a programming step is activated by touching a switc...

Страница 3: ...3 Getting Started Setup Sensors...

Страница 4: ...4...

Страница 5: ...l be turned on for 4 seconds then it will be off and start to work normally The transmitter will make a data transmission When there is a data transmission happened the LED will be on for 20ms After i...

Страница 6: ...the INDOOR TEMPERATURE section again to set the indoor temperature high alarm function the ON OFF and button will be flashing HI AL icon will light up Touch the button or button to change the value h...

Страница 7: ...ourth time to set the outdoor temperature low alarm function the ON OFF and button will be flashing LO AL icon will light up Touch the button or button to change the value hold the button or button fo...

Страница 8: ...alue for 3s the minimum value will be reset to current reading Outdoor humidity Procedures and settings are similar to Indoor humidity Wind speed Activate the wind related setting by 1 Touch the WIND...

Страница 9: ...the alarm function has been enabled 4 Touch the rain section the fourth time to display current maximum rain fall record Touch the rain section for 3s will reset the maximum rain fall value to curren...

Страница 10: ...hold the button or button for 3s to change the number in great step Touch the ON OFF button to choose the alarm on or off if alarm is enabled the speaker icon will be turned on indicating the alarm f...

Страница 11: ...hour Hold the button or button for 3s to change the number in great step 7 Touch the DATE section the seventh time button and button will be flashing Touch the button or button to set alarm minute Hol...

Страница 12: ...imum 4080 data sets of the Weather Station is only limited by the capacity of the PC s main memory PC software installation The installation of WH1081PC software is very simple double click the setup...

Страница 13: ...C 40 to 149 Resolution 0 1 C 0 2 Measuring range rel humidity 10 99 Rain volume display 0 9999mm show OFL if outside range Resolution 0 3mm if rain volume 1000mm 1mm if rain volume 1000mm Wind speed...

Страница 14: ...orized depot All rights reserved This handbook must not be reproduced in any form even in excerpts or duplicated or processed using electronic mechanical or chemical procedures without written permiss...