- 1 - 

   

Operation Manual 

 

 

About this manual 

Thank you and congratulations on selecting this professional weather station! We are positive you will enjoy 
the benefits of accurate weather readings and the precise radio controlled time information that our 
instruments offer. 
This manual will guide you step-by-step through setting up your WH1081PC device. Use this manual to 
become familiar with your professional weather station, and save it for future reference. 

 

Glossary of Common Terms 

 

LCD 

 

“LCD” is an acronym for ”Liquid Crystal Display”.    This is a common type of display screen used in 
televisions, computers, watches, and digital clocks.   
   

BAROMETER & BAROMETRIC PRESSURE 

 

A barometer is a device that measures the pressure of the air pushing on it—this measurement is called the 
barometric pressure.    We don’t actually feel the barometric pressure because the air pressure is pushing 
equally in every direction.   
   

RELATIVE AIR PRESSURE 

 

Relative air pressure is the same as the barometric pressure.    The calculation of relative air pressure is a 
combination of the absolute air pressure and the altitude.   
   

ABSOLUTE AIR PRESSURE 

 

Absolute air pressure is the actual air pressure on the barometer without regard to altitude.   
   

INCHES OF MERCURY 

(inHg)

 

 

Inches of Mercury is the common unit of measurement for air pressure in the United States.   
   

HECTOPASCALS 

(hPa)

 

 

Hectopascals are the common units of measurement for air pressure in the International System (SI) of 
measurement.    The hectopascal holds the same value   

 

Important Note: 

Before inserting batteries, please carefully read the operation manual. 

 

The touch screen weather station WH1081PC includes a base station(receiver), a transmitter unit, one wind 
direction sensor, one wind speed sensor, one rain gauge, USB cable and a PC software package on 
CD-ROM. 
 
The Base Station is equipped with a Touch Screen LCD Monitor and allows the display of a large variety of 
time and weather data.   
Left Top LCD:   

 

IN-OUT temperature and humidity 

Right Top LCD:  

 

Wind and Rain measurement 

Left Middle LCD: 

 

Weather Forecast(Tendency) 

Right Middle LCD: 

 

Air Pressure and Air Pressure History 

Bottom Line LCD: 

 

Time and Date, Memory Data Usage 

 

Note:

 The presence of the "Alarm-On icon" in the section means that the particular alarm has been enabled.     

 

 

Содержание WH1081PC

Страница 1: ...ure is a combination of the absolute air pressure and the altitude ABSOLUTE AIR PRESSURE Absolute air pressure is the actual air pressure on the barometer without regard to altitude INCHES OF MERCURY...

Страница 2: ...y slightly touching not pressing the related areas touch the flashing ON OFF or to make the corresponding selection or increase the value Every time a programming step is activated by touching a switc...

Страница 3: ...3 Getting Started Setup Sensors...

Страница 4: ...4...

Страница 5: ...l be turned on for 4 seconds then it will be off and start to work normally The transmitter will make a data transmission When there is a data transmission happened the LED will be on for 20ms After i...

Страница 6: ...the INDOOR TEMPERATURE section again to set the indoor temperature high alarm function the ON OFF and button will be flashing HI AL icon will light up Touch the button or button to change the value h...

Страница 7: ...ourth time to set the outdoor temperature low alarm function the ON OFF and button will be flashing LO AL icon will light up Touch the button or button to change the value hold the button or button fo...

Страница 8: ...alue for 3s the minimum value will be reset to current reading Outdoor humidity Procedures and settings are similar to Indoor humidity Wind speed Activate the wind related setting by 1 Touch the WIND...

Страница 9: ...the alarm function has been enabled 4 Touch the rain section the fourth time to display current maximum rain fall record Touch the rain section for 3s will reset the maximum rain fall value to curren...

Страница 10: ...hold the button or button for 3s to change the number in great step Touch the ON OFF button to choose the alarm on or off if alarm is enabled the speaker icon will be turned on indicating the alarm f...

Страница 11: ...hour Hold the button or button for 3s to change the number in great step 7 Touch the DATE section the seventh time button and button will be flashing Touch the button or button to set alarm minute Hol...

Страница 12: ...imum 4080 data sets of the Weather Station is only limited by the capacity of the PC s main memory PC software installation The installation of WH1081PC software is very simple double click the setup...

Страница 13: ...C 40 to 149 Resolution 0 1 C 0 2 Measuring range rel humidity 10 99 Rain volume display 0 9999mm show OFL if outside range Resolution 0 3mm if rain volume 1000mm 1mm if rain volume 1000mm Wind speed...

Страница 14: ...orized depot All rights reserved This handbook must not be reproduced in any form even in excerpts or duplicated or processed using electronic mechanical or chemical procedures without written permiss...