BOOK 0959
32
TABLE 9. OPERATING VOLTAGES AND SIGNALS
OUTPUT VDC
POWER SOURCE
(Single-phase)
Armature
Field
SPEED
REFERENCE
SIGNAL
MAGNETIC
CONTROL
VOLTAGE
115V, 50 or 60 Hz
0 - 90
50/100
230V, 50 or 60 Hz
0 - 180
100/200
0 -5 Vdc
0 - 10 Vdc
4 - 20Ma
24 VDC
TABLE 10. CONTROLLER WEIGHTS
CONTROLLER MODEL
WEIGHT - LBS (KG)
Rated Horsepower (HP)
1/6 - 2
3
2601 7.70
(3.50)
2601A 8.50
(3.86)
2601P0, P1, P3
11.60 (5.26)
2601AP0, P1, P3
12.40 (5.62)
2611, 2612,
3.25 (1.47)
2611A, 2612A,
3.80 (1.72)
2611P0, P1, P2
5.50 (2.50)
NA
2611AP0, P3
6.05 (2.75)
NA
2615 2.00
(0.91)
2615A 2.25
(1.02)
OPERATING CONDITIONS
1.
Altitude, Standard ........................................................................................ 1000 Meters (3300 Feet) Maximum
1
2. Ambient
Temperature..................................................................................................... 0 - 40°C (32°F - 104°F)
2
3. Line
Frequency Variation ............................................................................................................ ± 2 Hz Of Rated
4. Line
Voltage
Variation ..................................................................................................................±10% Of Rated
5. Relative
Humidity................................................................................................................. 95% Noncondensing
PERFORMANCE CHARACTERISTICS
1.
Controlled Speed Range ...................................................................................................0 To Motor Base Speed
2. Displacement
Power
Factor
(Rated Speed/Rated Load)................................................................................. 87%
3. Efficiency
(Rated Speed/Rated Load)
a.
Controller
Only............................................................................................................................................... 98%
b. Controller With Motor, Typical................................................................................................................. 85%
4. Speed
Regulation...............................................................................................................................See Table 11
1. Controller can be derated by 1% per 100 meters to operate at higher altitudes.
2. 55°C (131°F) maximum in enclosed areas where open-chassis controllers are mounted.
Содержание 2601 Series
Страница 1: ......
Страница 2: ...BOOK 0959 SERIES 2610 MKII 2601 SINGLE PHASE ADJUSTABLE SPEED DC MOTOR CONTROLLERS 1 6 3 HP...
Страница 12: ...BOOK 0959 7 FIGURE 1 CONTROLLER MOUNTING CONFIGURATIONS...
Страница 13: ...BOOK 0959 8 FIGURE 2 CONTROLLER MOUNTING DIMENSIONS...
Страница 23: ...BOOK 0959 18 Blank Page...
Страница 27: ...BOOK 0959 22 Blank Page...
Страница 35: ...BOOK 0959 30 Blank Page...
Страница 40: ...BOOK 0959 35 SECTION VII DRAWINGS...
Страница 41: ...BOOK 0959 36 Figure 22 Functional Schematic Series 2610MKII 2601...
Страница 42: ...BOOK 0959 37 Figure 23 Series 2610MKII Control Board 1 6 3HP...
Страница 43: ...BOOK 0959 38 Blank Page...
Страница 46: ...www fincor nett...