With your pump (Not Included) mounted 

on the ‘top’ of your tank this is how your 

bypass line will be configured. 

You may need to punch or drill the hole 

for your return line, approx. 7/8”. 

With your pump (Not Included) 

mounted on the ‘side’ of your 

tank this will be your plumbing 

configuration/setup. 

You may need to punch or drill 

the hole for your return line,  

approx. 13/16”. 

Testing the Sprayer 

NOTE: 

It is VERY important for you to test your sprayer with plain water before actual 

spraying is attempted. This will enable you to check the sprayer for leaks without 

the possibility of losing any expensive chemicals. 

  

Fill the tank about 1/2 full with plain water and drive to the starting place for spraying.  

 

When you are ready to spray, turn the boom valve to the “on” position (Detail A). This will start 

solution spraying from the tips of the boom. The pressure will decrease slightly when the boom 

is spraying.  

Adjust the pressure by turning the “ON/OFF” valve lever on the bypass line valve (Detail B). 

Make sure your pattern is sufficient. You may down-pressure the system by ‘bypassing’ solu-

tion back into the tank. This is achieved by opening the bypass valve. Regulating pressure is 

done in this manner. 

 

Read the operating instructions and initially begin spraying by closing the ‘Pressure Adjust’ 

valve and opening the boom line valve (Detail A). This will enable the air in the line to be elimi-

nated (purged) through all the tips, while building pressure. When everything tests all right (no 

leaks and good pressure), add the desired chemicals to the mixture and water combination 

and start your spraying operation. Adjust the pressure and spray as you did in the testing pro-

cedure. 

Conditions of weather and terrain must be considered when setting the sprayer. Do not spray 

on windy days. Protective clothing must be worn in some cases. 

 

Be sure to read the chemical label(s) before application! 

 

Operation 

Fill the tank part way with water and then add the desired amount of chemical to be sprayed. 

Finish filling tank to proper level. Turn the pump on and by depressing the “-” side of the rocker 

switch. The pump is equipped with a pressure switch that is pre-set at the factory to shut the 

pump off when all discharges are closed. 

 

The pump will turn back on when one of the following actions occurs: 

 

Boom valve is opened to broadcast spray with the boom. 

 

Bypass valve is opened to re-circulate solution back into the tank. 

 

When spraying with the boom, pressure may be reduced by slowly opening the bypass valve 

until desired pressure is achieved. Opening the valve decreases pressure, closing the valve 

increases pressure. When spraying with the boom, the proper method to set the pressure is to 

open the boom valve completely and if a lower pressure is desired, then slowly open the by-

pass valve until that pressure is obtained. 

 

For the safest and most efficient chemical application, you will need to calibrate your sprayer 

using the tip and speed charts. Once you have determined the proper speed and pressure 

settings, you will need to consult your chemical label for the amount of chemical to be added 

to the tank. Read the entire label. Use only according to label directions. 

Manifold Valves CLOSED 

Final Step: 

Plumbing 

configuration. 

See Page 7 for 

the Parts List and 

Part Numbers 

Detail A 

Detail B 

Содержание ATVBK-3025-QR

Страница 1: ... CST If you should have a question or experience a problem with your Fimco Industries Product Visit our website www fimcoindustries com or call the Toll free number above Our technical support representatives will be happy to help you In most cases a customer service rep can resolve the problem over the phone To obtain prompt efficient service always remember to give the following information Corr...

Страница 2: ... s carton ATVBK 3025 QR 5302334 Contents of Parts Bag 5278296 Contents of Bracket Kit 5278138 Wet Boom Sub Assembly 5275712 End Nozzle 5275122 Pkg of 2 5275713 Manifold Detail 5281541 See Page 7 for the Manifold Assembly Part Numbers ...

Страница 3: ...you and just hanging over the edge of the table or flat surface you are assembling this on Secure the boom mounting brackets to the tank mounting brackets with Cam handles as shown in Detail A You can position them as needed within the slot on the bracket Just be sure that the surfaces of both brackets are even with each other You are now ready to mount this unit to an ATV using ratchet straps NOT...

Страница 4: ...75122 Each click of the ratcheting motion is approx 15 This nozzle mounting stem Has a ratcheting motion For proper optimal spray coverage The nozzle must be at a 15 angle The 15 angle shown will prevent the outer Nozzles from overlapping with the center nozzle On Off Valve Positions Note The check valve diaphragm can fall out during transport if the knob is not turned to the ON or OFF position On...

Страница 5: ...xture and water combination and start your spraying operation Adjust the pressure and spray as you did in the testing pro cedure Conditions of weather and terrain must be considered when setting the sprayer Do not spray on windy days Protective clothing must be worn in some cases Be sure to read the chemical label s before application Operation Fill the tank part way with water and then add the de...

Страница 6: ...al object Even the slightest damage can change the flow rate and spray distribution Water rinse and dry the tips before storing WARNING Some chemicals will damage the pump valves if allowed to soak untreated for a length of time ALWAYS flush the pump as instructed after each use DO NOT allow chemicals to sit in the pump for extended times of idleness Follow the chemical manufacturer s instructions...

Страница 7: ...Page 7 Exploded View Parts List ATVBK 3025 QR 5302334 End Nozzle Assembly 5275122 Center Nozzle Assembly 5275123 Boomless Wet Boom Assembly Exploded View Parts List 5275260 ...

Страница 8: ...Warranty you must 1 provide written notice to Fimco Ind of the defect during the Warranty Period and within thirty 30 days after the defect becomes apparent or the repair becomes necessary at the following address Fimco Ind 1000 Fimco Lane North Sioux City SD 57049 and 2 make the Equipment available to Fimco Ind or an authorized dealer within a reasonable period of time For more information about ...

Отзывы: