background image

Page 9 

 

Multi-Lid Directions 

1.  Open fill cap and place garden hose into tank. Fill tank to desired gallon marker, if marker 

is above the bottom of calibration container, stop before water     reaches calibration 

container. This is done to help chemical mix better and keep foaming of chemical to a 

minimum later. 

2.  Remove Multi-Lid and use calibration container to measure the correct amount of chemi-

cal for the water being used. 

3.  Pour chemical into tank and tighten Multi-Lid back onto tank. If desired amount of water 

was added in step 1, you are done. Be sure to press firmly on fill cap to seal with Multi-

Lid. If desired amount of water was not met in step 1, proceed to step 4. 

4.  Open fill cap and place garden hose into tank. Add water to the desired gallon marker. 

Close fill cap, pressing firmly to seal cap to Multi-Lid. 

NOTE: If water and chemical has not mixed properly, use the pressure adjustment control on 

the manifold to recirculate the mixture through tank. 

34½” 

16¾”

 

47” 

34½”

 

36” 

Technical Specifications 

 

Properly secure the tank to your utility vehicle, using tie-down or ratchet straps (Not Included). 

 

Tank straps may be installed through the handles to help prevent straps from slipping off tank if too loose.  

 

Handles can be used to lift the empty tank in and out of the box. 

 

Stay within your utility vehicle’s weight limits. This unit when filled with water weighs approx.: 650 lbs. 

Consult the owner’s manual for your vehicle. 

UTV Intake 

Plumbing 

(5281072) 

 

Refer to Parts 

List Page 7 

for Part Numbers 

Intake Detail 

Ref. #2 is found inside 

of the tank

 

Содержание 5303071

Страница 1: ... a customer service rep can resolve the problem over the phone To obtain prompt efficient service always remember to give the following information Correct Part Description and or part number Model number and Serial Number Part descriptions and numbers can be obtained from the illustrated parts list section s of this manual General Information Thank you for purchasing this product The purpose of t...

Страница 2: ...d to the manifold The boom hose can be cut to length if needed Once fully assembled to remove the sprayer from a UTV Box disconnect the boom supply hose from the manifold using the quick connect fitting Then loosen the two lobe knobs on the tank mounts and slide the boom out and set aside Then the tank can be removed and set on the ground without damaging the tank or boom The handles can be used t...

Страница 3: ...en disconnect the negative black connection and finally the positive red connection The lead wire has an On Off switch to activate the pump is on and O is off Fill the tank part way with water and then add the desired amount of chemical to be sprayed Finish filling tank to proper level Turn the pump on and by depressing the side of the rock er switch The pump is equipped with a pressure switch tha...

Страница 4: ...as much as possible Then pour enough pink RV antifreeze into the tank so that when the pump is turned on you can pump the antifreeze throughout the entire plumbing system including the bypass Make sure to operate the boom and handgun until you see pink fluid spraying from the nozzles Leave any remaining antifreeze in the tank Before your next usage rinse the antifreeze from the sprayer with clean ...

Страница 5: ...r clogged strainer filter Check for cracks in the pump housing Check for empty product supply Low Pressure Low Flow Check for leaks in the discharge line Check for restriction in the discharge line Check for debris in nozzle orifice Check for clogged strainer Check for proper voltage try another 12 volt battery Pulsating flow surging Low flow may cause pump to surge Spray wand is adjusted for a sm...

Страница 6: ...ail A Detail B Boom Feeder Hose Refer to Page 9 for the UTV intake assembly breakdown Reference 6 Exploded View UTV 65 7 PRO 5303071 Refer to Parts List Next Page for Part Numbers See Detail A See Intake Detail On Page 9 ...

Страница 7: ...ect elbow look inside the cap you ll see a hexagon shape behind the flat washer using an allen wrench head of a bolt or a flat head screwdriver something just big enough to catch the edges and while holding the elbow and cap give it a snug twist clockwise to tighten The elbow is a two piece interlocking mecha nism and if loose will leak Manifold O Ring 5072514 ...

Страница 8: ... spacing Suggested Minimum Spray Height 16 18 above what is being sprayed to plant not ground Optimum Spray Height 20 110 wide tapered flat spray angle with air induction tech nology for better drift management Made of 2 piece UHMWPE polymer construction which provides excellent chemical resistance including acids as well as exceptional wear life Compact size to prevent tip damage Excellent for sy...

Страница 9: ...ep 4 4 Open fill cap and place garden hose into tank Add water to the desired gallon marker Close fill cap pressing firmly to seal cap to Multi Lid NOTE If water and chemical has not mixed properly use the pressure adjustment control on the manifold to recirculate the mixture through tank 34 16 47 34 36 Technical Specifications Properly secure the tank to your utility vehicle using tie down or rat...

Страница 10: ...ited Warranty you must 1 provide written notice to Fimco Ind of the defect during the Warranty Period and within thirty 30 days after the defect becomes apparent or the repair becomes necessary at the following address Fimco Ind 1000 Fimco Lane North Sioux City SD 57049 and 2 make the Equipment available to Fimco Ind or an authorized dealer within a reasonable period of time For more information a...

Отзывы: