Fimco 5303070 Скачать руководство пользователя страница 8

Page 8 

 

Cleaning the Check Valve

If you’re experiencing little to no pressure or the pump is not priming and you’ve checked your 

filter screen and it’s clean, and you’ve gone through the other trouble shooting tips, you may 

need to clean the check valve. 

 

Remove the head of the pump, which is held on by 7 screws. 

 

The first piece inside the head of the pump is called a check valve, it’s the part responsible for building up pressure 
and pumping water/solution through the lines.  

 

Clean the check valve under hot, soapy water (such as a good grade dish soap).  

 

Give it a very light scrubbing with something like an old toothbrush, something with soft bristles. 

 

Then let it soak for about an hour or so in the hot soapy solution and replace in the pump and reassemble the pump. 

 

Most times this will restore most, if not all of the prime of a pump. 

If you’re still having issues with pressure after this step, it would be recommended to replace this part. 

Checking the Pressure Switch

If your motor is not running and you’ve checked the following: for loose wiring connections, fuse, the switch on the 

lead wire was “ON” and made sure you were connected to a fully charged battery and everything is fine, but the  

motor won’t run, then it’s time to check to see if the pressure switch is bad. 

 

Remove the cover off the 1” square box (pressure switch) on the head of the pump, the cover is held on by   
one phillips-head screw. This will  expose the two red wires. 

 

With the pump connected to a good 12 volt power source and everything on. 

 

Slip the two red wires off the terminals and touch them together.  

 

If the motor runs, it means the pressure switch is bad and needs to be replaced.  

 

Warning:

 It is NOT recommended to run the pump this way, as the pump will continue  

to run and not shut off.  

 

This could result in blown hoses when all discharges are closed. 

Also, this could result in premature failure of the pump completely. 

Quarter turn at a time clockwise until surging stops

Check that shut-off valve on inlet (if applicable) is open

Pump continues to run:

Bypass (if applicable) is not completely closed
System has leaks

Check for worn or dirty check valve

Fuse blows:

Excessive voltage
Improper adjustment of pressure switch
Defective pressure switch

Pump surges:

Low flow may cause pump to surge
Spray wand is adjusted for a small or fine spray pattern
Slightly open bypass (if applicable) to overcome
If needed, pressure switch may need to be adjusted

Check for defective pressure switch

Low Pressure/Low Flow:

Check for a clogged strainer
Check for proper voltage
Check for worn or dirty check valve

Troubleshooting

Pump will not run:

Check for loose wiring
Make sure the ON/OFF switch is on
Check the fuse

Содержание 5303070

Страница 1: ...ting instructions for both the sprayer and the Volt Edge system before using IMPORTANT This sprayer comes with an On Off shut off valve located at the inlet location of the tank towards the underside You must make sure the valve is in the open position before using your sprayer OWNER S MANUAL BEFORE RETURNING THIS PRODUCT FOR ANY REASON PLEASE CALL 1 800 831 0027 MONDAY FRIDAY 8 00 AM TO 5 00 PM C...

Страница 2: ...ur sprayer s carton 20V 30 2N TRL Tank Plumbing Pre Assembly Owner s Manual Breakaway Boom Bracket Kit LG 30 TRL 5278366 Tongue Assembly Wireless Remote 5164291 20V 1A Lithium Battery Charger 5164281 Contents of Parts Bag 5281516 ...

Страница 3: ...6 x 2 1 4 Flanged bolts tank support axle support and the preassembled tongue Turn the tank upside down Detail A Loosely attach the tank support and axle support with 4 lock screws Just start the bolts do not tighten on either support Detail B Slide the tongue assembly into place and using the 2 flanged bolts attach to the tank and tighten Do Not Overtighten Then tighten the 4 lock screws Do Not O...

Страница 4: ...ank using the two screws DO NOT TIGHTEN Detail C Locate in the parts bag 2 5 16 18 x 5 8 Flanged Bolts and 2 Whiz Nuts Attach the Boom Top Straps to the Boom Assembly using the two bolts and whiz nuts Tighten all Bolts from Details A B C DO NOT OVERTIGHTEN After the boom is installed attach the 8 Feeder Hose to the 90 HB Elbow on the manifold The boom is now installed Locate the Pressure Gauge in ...

Страница 5: ...d then add the desired amount of chemical to be sprayed Finish filling tank to proper level Turn the pump on and by depressing the side of the rock er switch The pump is equipped with a pressure switch that is pre set at the factory to shut the pump off when all discharges are closed The pump will turn back on when one of the following actions occurs Handgun lever is squeezed to spray the handgun ...

Страница 6: ...tructions on disposal of all waste water from the sprayer Winter Storage Prepare the sprayer for end of season storage by running RV antifreeze through the system This will keep internal parts lubricated protect against corrosion and keep the unit from freezing Note RV antifreeze is non toxic and biodegradable and generally safer for the environment than automotive antifreeze Before storing your s...

Страница 7: ...ischarge line Check for restriction in the discharge line Check for debris in nozzle orifice Check for clogged strainer Check for proper voltage try another 12 volt battery Pulsating flow surging Low flow may cause pump to surge Spray wand is adjusted for a small or fine spray pattern Slightly open bypass if applicable to overcome If needed pressure switch may need to be adjusted adjust a quarter ...

Страница 8: ...o see if the pressure switch is bad Remove the cover off the 1 square box pressure switch on the head of the pump the cover is held on by one phillips head screw This will expose the two red wires With the pump connected to a good 12 volt power source and everything on Slip the two red wires off the terminals and touch them together If the motor runs it means the pressure switch is bad and needs t...

Страница 9: ...reduce the risk of injury basic safety precautions should always be followed including Charge battery packs only in Volt Edge 20V max Lithium ion compatible chargers Do not store or charge the battery pack in locations where the temperature may reach above 95 F 35 C or below 40 F 4 C Do not use the battery pack in locations where the temperature may reach above 120 F 49 C or below 4 F 20 C Warning...

Страница 10: ...y Chargers DOE energy conser vation standards specified in the Code of Federal Regulations at 10 CFR 430 32 z This device complies with CEC Section 1605 1 w of energy efficiency standars for federally regulated battery chargers of California Code of Regulations This device complies with NRCAN EEV CSA C381 2 17 May 2017 and Canada s Energy Efficiency Regulations This device complies with cETLus cer...

Страница 11: ...d it is fully seated 4 Press the power button and confirm the green LED turns on Signaling the power is on 5 Test the remote by pressing the OFF button on the remote and both green and red receiver LEDs will turn on Signaling the power output is off while the power is on 6 Press the ON button on the remote The red LED will turn off and power output will return 7 Press the power button again to tur...

Страница 12: ...f this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit differe...

Страница 13: ...Page 13 Exploded View Parts List 20V 30 2N TRL 5303070 See Intake Assembly Detail Page 15 See Manifold Assembly Detail Page 15 See Boom Assembly Parts List Next Page ...

Страница 14: ...gested Minimum Spray Height 18 20 above what is being sprayed to plant not ground Optimum Spray Height 39 Wide angle spray nozzle height is influenced by nozzle orientation The critical factor is to achieve a minimum 30 overlap Excellent spray distribution for uniform coverage along the boom Nozzle design incorporates a pre orifice to pro duce larger droplets for less drift Hinge Detail ...

Страница 15: ...s with an On Off shut off valve located at the inlet location of the tank towards the underside You must make sure the valve is in the open position before using your sprayer See Page 13 for Part Numbers Manifold Detail Intake Detail ...

Страница 16: ...obtain warranty service under this Limited Warranty you must 1 provide written notice to Fimco Ind of the defect during the Warranty Period and within thirty 30 days after the defect becomes apparent or the repair becomes necessary at the following address Fimco Ind 1000 Fimco Lane North Sioux City SD 57049 and 2 make the Equipment available to Fimco Ind or an authorized dealer within a reasonable...

Отзывы: