Fimco 5303070 Скачать руководство пользователя страница 11

Page 11 

 

Important charging notes:

 

 

1. 

Longest life and best performance can be obtained if the battery pack is charged with the air temperature is between 50°F (10°C) and  

80°F (26°C). 

2. 

The charger and battery pack may become warm to the touch while charging. This is normal and does not indicate a problem. Ensure the 

vents are not blocked to allow cooling. 

3. 

The battery pack should be recharged when it no longer powers the equipment. Do not continue to attempt using the battery if low power 

is indicated. You may recharge a partially discharged battery pack without damaging the battery pack. 

4. 

Do not freeze or submerge the charger in water or any other liquid. 

 

Warning:

 

Shock Hazard. Do not allow any liquid to get inside the charger. Never attempt to open the battery pack for any reason. If the plastic housing of the 

battery pack breaks for cracks, return to a recycling center and replace the charger. 

 

The receiver is designed to power all High-Flo 12V pumps. The receiver will output 12V DC and is limited to 15A max. current. 

 

To install the receiver, the pump will be removed. The base plate and adjustable support will be placed un-

der the pump and screwed down with the longer screws supplied in the kit. The receiver has already been 

pinned to the base plate, but it can be removed to make screw installation easier by sliding the pin out. Then 

the receiver is slid into the adjustable support bracket. It will click into the first position, sized for the Pro 

Series pumps and the 4.5 pump.  

 

2.4 GPM Pump w/Manifold Configuration: 

Place pump on base plate and screw down to tank or frame, using the (3) #10-24 x 3/4” and (1) #10-24 x 1” 

screws. The 1” screw goes through the manifold support bracket. Click the receiver into the second position 

of the adjustable support. 

 

 

 

Operating Procedure:

 

 

1. 

Charge the battery following the charging procedure. 

2. 

Ensure all fasteners are tight and pump connections are secure. 

3. 

Install the battery ensuring the base is connected and it is fully seated. 

4. 

Press the power button and confirm the green LED turns on. Signaling the power is on. 

 

 

 

 

5. 

Test the remote by pressing the OFF button on the remote and both green and red receiver LEDs will turn on. Signaling the power 

output is off while the power is on. 

 

 

6. 

Press the ON button on the remote. The red LED will turn off and power output will return. 

7. 

Press the power button again to turn the receiver off. 

8. 

Connect the receiver 2-pin connector to the pump. 

9. 

Press the power button to turn the receiver on and the pump will run. 

10.  When spraying is complete press the power button to turn off the receiver. 

11.  Recharge the battery to properly maintain the battery pack. 

 

Receiver Diagnostics:  

 

The receiver is designed to detect certain problems that can arise with the battery packs or the pump. Problems are indicated by the red and green 

LEDs. 

 

Battery Life 

 

When the battery is approaching fully discharged, the green LED will begin to flash. When the battery is fully discharged, power will stop 

being supplied to the pump and the green LED will continue flashing. Power off the receiver and charge the battery. 

 

 

Protection Mode 

 

When the receiver identifies a problem with the pump, the power output will stop and the red LED will flash and the green LED will remain 

illuminated. The red LED will blink in cycles to identify the problem. Press the power button turning the receiver off to reset the system. Wait 

30 seconds and press the power button to resume operation. 

 

Red LED flashing two times:  

 

Open circuit protection. The receiver power is on without powering consumption. 

 

Red LED flashing three times:   

Incorrect voltage. Voltage being supplied to the receiver is outside the range. 

 

Red LED flashing four times: 

 

High current protection. The pump has drawn current above the limit. 

 

Red LED flashing ten times:  

 

Temperature protection. The system has measured the temperature to be outside safe operating  

 

 

 

 

 

 

 

 

 

temperatures.

 

Leaving the battery in the charger.

 

The charger and battery pack can be left connected with the green LED indicating the charger is maintaining the battery continuously. The charger will 

keep the battery pack fresh and fully charged. 

Содержание 5303070

Страница 1: ...ting instructions for both the sprayer and the Volt Edge system before using IMPORTANT This sprayer comes with an On Off shut off valve located at the inlet location of the tank towards the underside You must make sure the valve is in the open position before using your sprayer OWNER S MANUAL BEFORE RETURNING THIS PRODUCT FOR ANY REASON PLEASE CALL 1 800 831 0027 MONDAY FRIDAY 8 00 AM TO 5 00 PM C...

Страница 2: ...ur sprayer s carton 20V 30 2N TRL Tank Plumbing Pre Assembly Owner s Manual Breakaway Boom Bracket Kit LG 30 TRL 5278366 Tongue Assembly Wireless Remote 5164291 20V 1A Lithium Battery Charger 5164281 Contents of Parts Bag 5281516 ...

Страница 3: ...6 x 2 1 4 Flanged bolts tank support axle support and the preassembled tongue Turn the tank upside down Detail A Loosely attach the tank support and axle support with 4 lock screws Just start the bolts do not tighten on either support Detail B Slide the tongue assembly into place and using the 2 flanged bolts attach to the tank and tighten Do Not Overtighten Then tighten the 4 lock screws Do Not O...

Страница 4: ...ank using the two screws DO NOT TIGHTEN Detail C Locate in the parts bag 2 5 16 18 x 5 8 Flanged Bolts and 2 Whiz Nuts Attach the Boom Top Straps to the Boom Assembly using the two bolts and whiz nuts Tighten all Bolts from Details A B C DO NOT OVERTIGHTEN After the boom is installed attach the 8 Feeder Hose to the 90 HB Elbow on the manifold The boom is now installed Locate the Pressure Gauge in ...

Страница 5: ...d then add the desired amount of chemical to be sprayed Finish filling tank to proper level Turn the pump on and by depressing the side of the rock er switch The pump is equipped with a pressure switch that is pre set at the factory to shut the pump off when all discharges are closed The pump will turn back on when one of the following actions occurs Handgun lever is squeezed to spray the handgun ...

Страница 6: ...tructions on disposal of all waste water from the sprayer Winter Storage Prepare the sprayer for end of season storage by running RV antifreeze through the system This will keep internal parts lubricated protect against corrosion and keep the unit from freezing Note RV antifreeze is non toxic and biodegradable and generally safer for the environment than automotive antifreeze Before storing your s...

Страница 7: ...ischarge line Check for restriction in the discharge line Check for debris in nozzle orifice Check for clogged strainer Check for proper voltage try another 12 volt battery Pulsating flow surging Low flow may cause pump to surge Spray wand is adjusted for a small or fine spray pattern Slightly open bypass if applicable to overcome If needed pressure switch may need to be adjusted adjust a quarter ...

Страница 8: ...o see if the pressure switch is bad Remove the cover off the 1 square box pressure switch on the head of the pump the cover is held on by one phillips head screw This will expose the two red wires With the pump connected to a good 12 volt power source and everything on Slip the two red wires off the terminals and touch them together If the motor runs it means the pressure switch is bad and needs t...

Страница 9: ...reduce the risk of injury basic safety precautions should always be followed including Charge battery packs only in Volt Edge 20V max Lithium ion compatible chargers Do not store or charge the battery pack in locations where the temperature may reach above 95 F 35 C or below 40 F 4 C Do not use the battery pack in locations where the temperature may reach above 120 F 49 C or below 4 F 20 C Warning...

Страница 10: ...y Chargers DOE energy conser vation standards specified in the Code of Federal Regulations at 10 CFR 430 32 z This device complies with CEC Section 1605 1 w of energy efficiency standars for federally regulated battery chargers of California Code of Regulations This device complies with NRCAN EEV CSA C381 2 17 May 2017 and Canada s Energy Efficiency Regulations This device complies with cETLus cer...

Страница 11: ...d it is fully seated 4 Press the power button and confirm the green LED turns on Signaling the power is on 5 Test the remote by pressing the OFF button on the remote and both green and red receiver LEDs will turn on Signaling the power output is off while the power is on 6 Press the ON button on the remote The red LED will turn off and power output will return 7 Press the power button again to tur...

Страница 12: ...f this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit differe...

Страница 13: ...Page 13 Exploded View Parts List 20V 30 2N TRL 5303070 See Intake Assembly Detail Page 15 See Manifold Assembly Detail Page 15 See Boom Assembly Parts List Next Page ...

Страница 14: ...gested Minimum Spray Height 18 20 above what is being sprayed to plant not ground Optimum Spray Height 39 Wide angle spray nozzle height is influenced by nozzle orientation The critical factor is to achieve a minimum 30 overlap Excellent spray distribution for uniform coverage along the boom Nozzle design incorporates a pre orifice to pro duce larger droplets for less drift Hinge Detail ...

Страница 15: ...s with an On Off shut off valve located at the inlet location of the tank towards the underside You must make sure the valve is in the open position before using your sprayer See Page 13 for Part Numbers Manifold Detail Intake Detail ...

Страница 16: ...obtain warranty service under this Limited Warranty you must 1 provide written notice to Fimco Ind of the defect during the Warranty Period and within thirty 30 days after the defect becomes apparent or the repair becomes necessary at the following address Fimco Ind 1000 Fimco Lane North Sioux City SD 57049 and 2 make the Equipment available to Fimco Ind or an authorized dealer within a reasonable...

Отзывы: