Fimco 5302317 Скачать руководство пользователя страница 7

Page 7 

 

DO 

 

Clean and rinse your pump after each use with Fimco Tank 
Neutralizer 

 

Winterize your pump or sprayer by rinsing, draining and  
running RV Antifreeze through it before storing for the winter. 

 

Use clean water for your spray mixture 

 

Store inside a building when not in use. 

DON’T 

 

Use to pump bleach. 

 

Use to pump petroleum products such as diesel fuel,    
gasoline or kerosene 

 

Leave your pump sit with spray mixture in it for extended 
periods 

 

Use dirty or unfiltered water for spraying 

Troubleshooting the Pump: 

Motor does not run: 

 

Check for loose wiring connection(s). 

 

Make sure the 'ON/OFF' switch in the lead wire assembly 

is in the 'ON' position. "I" is the 'ON' position and 'O' is 

the 'OFF' position. 

 

Check for defective pressure switch. Make sure you are 

connected to a good  12 volt power source. Make sure 

any on/off switches are in the 'on' position.  Remove the 

cap to the pressure switch. Pull both red wires off of their 
terminals, and touch the two ends together. If your pump 

runs when you do this, your   pressure switch will need to 

be replaced. 

 

Check the fuse. 

 

Check for low voltage at the power supply. 

 

 

Pump does not prime: 

 

Check for air leaks in supply line. 

 

Check for debris in the check valve assembly. 

 

Check for defective check valve. 

 

Check for clogged strainer/filter. 

 

Check for cracks in the pump housing. 

 

Check for empty product supply. 

 

Low Pressure/Low Flow: 

 

Check for leaks in the discharge line. 

 

Check for restriction in the discharge line. 

 

Check for debris in nozzle orifice. 

 

Check for clogged strainer. 

 

Check for proper voltage—try another 12-volt battery. 

Pulsating flow (surging): 

 

Low flow may cause pump to surge. 

 

Spray wand is adjusted for a small or fine spray pattern. 

 

Slightly open bypass (if applicable) to overcome. 

 

If needed, pressure switch may need to be adjusted—

adjust a quarter turn at a time clockwise until surging 

stops. 

 

Check for defective pressure switch. 

 

Check for leaks in the discharge line. 

 

Check for restriction in the discharge line. 

 

Check for debris in nozzle orifice. 

 

Discharge hose may be too long. 

 

Check for clogged strainer. 

 
Motor continues to run after discharge is shut off: 

 

Check for empty product supply. 

 

Check for open bypass valve. (if equipped) 

 

Check for low voltage. 

 

Check for leak in discharge line. 

 

Check for defective pressure switch. 

 

System has leaks. 

 

Fuse blows: 

 

Excessive voltage. 

 

Improper adjustment of pressure switch. 

 

Damaged or defective wiring harness. 

 

Defective pressure switch. 

Replacement Pump:  5151087 

 

 

 

 

 

 

Includes:   

 

 

 

 

 

 

 

1/2” MNPT Port Kit Fitting  

 

 

 

 

 

 

 

 

#5168832 

 

 

 

 

 

 

 

1/2” Hose Barb Port Kit Fitting  

 

 

 

 

 

 

 

 

#5168833 

 

 

 

 

 

 

 

3/8” Hose Barb Port Kit Fitting  

 

 

 

 

 

 

 

 

#5168836 

Pump Model:  5281371 

2.4 GPM, 60 PSI 

Available Replacement Parts 

Содержание 5302317

Страница 1: ...On Off shut off valve located at the inlet location of the tank towards the underside You must make sure the valve is in the open position before using your sprayer OWNER S MANUAL BEFORE RETURNING THIS PRODUCT FOR ANY REASON PLEASE CALL 1 800 831 0027 MONDAY FRIDAY 8 00 AM TO 5 00 PM CST If you should have a question or experience a problem with your Fimco Industries Product Visit our website www ...

Страница 2: ...Page 2 Tires Contents of your sprayer s carton LG 30 TRL Tank Plumbing Pre Assembly Owner s Manual Contents of Parts Bag 5278364 Breakaway Boom Bracket Kit LG 30 TRL 5278366 Tongue Assembly ...

Страница 3: ...6 x 2 1 4 Flanged bolts tank support axle support and the preassembled tongue Turn the tank upside down Detail A Loosely attach the tank support and axle support with 4 lock screws Just start the bolts do not tighten on either support Detail B Slide the tongue assembly into place and using the 2 flanged bolts attach to the tank and tighten Do Not Overtighten Then tighten the 4 lock screws Do Not O...

Страница 4: ...ank using the two screws DO NOT TIGHTEN Detail C Locate in the parts bag 2 5 16 18 x 5 8 Flanged Bolts and 2 Whiz Nuts Attach the Boom Top Straps to the Boom Assembly using the two bolts and whiz nuts Tighten all Bolts from Details A B C DO NOT OVERTIGHTEN After the boom is installed attach the 8 Feeder Hose to the 90 HB Elbow on the manifold The boom is now installed Locate the Pressure Gauge in ...

Страница 5: ...n disconnect the negative black connection and finally the positive red connection The lead wire has an On Off switch to activate the pump is on and O is off Fill the tank part way with water and then add the desired amount of chemical to be sprayed Finish filling tank to proper level Turn the pump on and by depressing the side of the rock er switch The pump is equipped with a pressure switch that...

Страница 6: ...cturer s instructions on disposal of all waste water from the sprayer Winter Storage Prepare the sprayer for end of season storage by running RV antifreeze through the system This will keep internal parts lubricated protect against corrosion and keep the unit from freezing Note RV antifreeze is non toxic and biodegradable and generally safer for the environment than automotive antifreeze Before st...

Страница 7: ... defective check valve Check for clogged strainer filter Check for cracks in the pump housing Check for empty product supply Low Pressure Low Flow Check for leaks in the discharge line Check for restriction in the discharge line Check for debris in nozzle orifice Check for clogged strainer Check for proper voltage try another 12 volt battery Pulsating flow surging Low flow may cause pump to surge ...

Страница 8: ...an hour or so in the hot soapy solution and replace in the pump and reassemble the pump Most times this will restore most if not all of the prime of a pump If you re still having issues with pressure after this step it would be recommended to replace this part Checking the Pressure Switch If your motor is not running and you ve checked the following for loose wiring connections fuse the switch on ...

Страница 9: ...Page 9 See Intake Assembly Detail Page 11 See Manifold Assembly Detail Page 11 See Boom Assembly Parts List Next Page Exploded View Parts List LG 30 TRL 5302317 ...

Страница 10: ...0 spacing Suggested Minimum Spray Height 18 20 above what is being sprayed to plant not ground Optimum Spray Height 39 Wide angle spray nozzle height is influenced by nozzle orientation The critical factor is to achieve a minimum 30 overlap Excellent spray distribution for uniform coverage along the boom Nozzle design incorporates a pre orifice to pro duce larger droplets for less drift ...

Страница 11: ...mbly 5281537 Intake Assembly 5278143 This sprayer comes with an On Off shut off valve located at the inlet location of the tank towards the underside You must make sure the valve is in the open position before using your sprayer ...

Страница 12: ...obtain warranty service under this Limited Warranty you must 1 provide written notice to Fimco Ind of the defect during the Warranty Period and within thirty 30 days after the defect becomes apparent or the repair becomes necessary at the following address Fimco Ind 1000 Fimco Lane North Sioux City SD 57049 and 2 make the Equipment available to Fimco Ind or an authorized dealer within a reasonable...

Отзывы: