Fimco 5302317 Скачать руководство пользователя страница 6

Page 6 

 

Using the Boom Nozzles 

Four things must be considered before spraying with the boom. 

 

How much chemical must be mixed in the tank. 

 

Rate of spray (gallons per acre to be sprayed). 

 

What pressure (p.s.i.) will be used. 

 

Speed traveled (mph) while spraying. 

 

Refer to the chemical label to determine your chemical mixture 

 

See the tip chart to determine the pressure to be used. The chart will also show the speed used when spraying. 

 

Start the pump and open the valve to the boom nozzles. 

 

Check the spray pattern. Usually you can see the coverage better on a solid concrete surface, such as a driveway. 

 

Maintenance During/After Spraying 

Periodically check the strainer and clean the screen on your intake line. 

 

Proper care and maintenance will prolong the life of your sprayer. 

 

 

 

 

 

 

After use, drain the tank and store or dispose of chemical properly. Fill the sprayer half way with clean water. Start the pump and allow the water to 

pump through the entire plumbing system and nozzles. Drain and then refill half full, add the recommended amount of a good quality tank cleaner, 

such as FIMCO Tank Neutralizer and Cleaner. (If no tank cleaner is available, you may substitute dish soap for this step, about 1-2 oz. per gallon).  

Turn pump on and circulate through system for 15 minutes and then spray out through boom and handgun nozzles. Refill sprayer half way with clean 

water and repeat. Follow the chemical manufacturer’s disposal instructions of all wash or rinsing water.  

If boom or handgun nozzles need cleaning, remove them from the sprayer and soak in warm soapy water. Clean with a soft bristled brush or toothpick 

if necessary. Never use a metal object. Even the slightest damage can change the flow rate and spray distribution. Water rinse and dry the tips before 

storing. 

 

WARNING: 

Some chemicals will damage the pump valves if allowed to soak untreated for a length of time! ALWAYS flush the pump as 

instructed after each  use. DO NOT allow chemicals to sit in the pump for extended times of idleness. Follow the chemical manufacturer’s 

instructions on disposal of all waste water from the sprayer.

 

 

Winter Storage 

Prepare the sprayer for end-of-season storage by running RV antifreeze through the system. This will keep internal parts lubricated, protect against 

corrosion and keep the unit from freezing. 

Note: RV antifreeze is non-toxic and biodegradable and generally safer for the environment than automotive 

antifreeze.

 

Before storing your sprayer for winter or long term storage, thoroughly clean and drain it as much as possible. Then pour enough pink RV antifreeze 

into the tank so that when the pump is turned on you can pump the antifreeze throughout the entire plumbing system, including the bypass. Make sure 

to operate the boom and handgun until you see pink fluid spraying from the nozzles. Leave any remaining antifreeze in the tank. Before your next 

usage, rinse the antifreeze from the sprayer with clean water. 

It is nearly impossible to drain all of the water from the sprayer and any trapped water can freeze in cold weather and damage parts of the sprayer. 

Pumping the antifreeze through the system will displace the water and help prevent this damage. 

 

Removing from storage: drain the antifreeze. Fill the tank with fresh water and run through the system. Dispose of antifreeze and flush water properly. 

Speed Chart 

  

Time Required in seconds 

Speed in M.P.H. 
(Miles Per Hour) 

100 Ft. 

200 Ft. 

300 Ft. 

1.0 

68 sec. 

136 sec.  

205 sec. 

2.0 

34 

68 

102 

3.0 

23 

45 

68 

4.0 

17 

34 

51 

5.0 

14 

27 

41 

6.0 

11 

23 

34 

7.0 

9.7 

19 

29 

8.0 

8.5 

17 

26 

9.0 

7.6 

15 

23 

10.0 

6.8 

14 

20 

1

MPH

2

MPH

3

MPH

4

MPH

5

MPH

10

.30

44

22

14.9

11.1

8.9

20

.42

63

31.5

20.9

15.7

12.6

30

.52

76

38

26

19.3

15.4

40

.60

90

45

30

22

17.8

1

MPH

2

MPH

3

MPH

4

MPH

5

MPH

10

.30

1.01

.5

.34

.254

.204

20

.42

1.4

.72

.48

.36

.29

30

.52

1.74

.87

.596

.44

.35

40

.60

2.06

1.00

.688

.50

.408

1

MPH

2

MPH

3

MPH

4

MPH

5

MPH

10

.30

.10

.05

.034

.025

.02

20

.42

.14

.072

.048

.036

.029

30

.52

.174

.087

.059

.044

.035

40

.60

.206

.10

.068

.05

.04

3

(Gray)

Tip Chart for TKT-VP3, TF-VP3 & 30DT3.0 Tips

Tip

No.

(Color)

Pressure

(psi)

Capacity

(GPM)

Gallons Per Acre - Based on Water

3

(Gray)

Tip

No.

(Color)

Pressure

(psi)

Capacity

(GPM)

Gallons Per 1000 Sq. Ft. - Based on Water

3

(Gray)

Tip

No.

(Color)

Pressure

(psi)

Capacity

(GPM)

Gallons Per 100 Sq. Ft. - Based on Water

Содержание 5302317

Страница 1: ...On Off shut off valve located at the inlet location of the tank towards the underside You must make sure the valve is in the open position before using your sprayer OWNER S MANUAL BEFORE RETURNING THIS PRODUCT FOR ANY REASON PLEASE CALL 1 800 831 0027 MONDAY FRIDAY 8 00 AM TO 5 00 PM CST If you should have a question or experience a problem with your Fimco Industries Product Visit our website www ...

Страница 2: ...Page 2 Tires Contents of your sprayer s carton LG 30 TRL Tank Plumbing Pre Assembly Owner s Manual Contents of Parts Bag 5278364 Breakaway Boom Bracket Kit LG 30 TRL 5278366 Tongue Assembly ...

Страница 3: ...6 x 2 1 4 Flanged bolts tank support axle support and the preassembled tongue Turn the tank upside down Detail A Loosely attach the tank support and axle support with 4 lock screws Just start the bolts do not tighten on either support Detail B Slide the tongue assembly into place and using the 2 flanged bolts attach to the tank and tighten Do Not Overtighten Then tighten the 4 lock screws Do Not O...

Страница 4: ...ank using the two screws DO NOT TIGHTEN Detail C Locate in the parts bag 2 5 16 18 x 5 8 Flanged Bolts and 2 Whiz Nuts Attach the Boom Top Straps to the Boom Assembly using the two bolts and whiz nuts Tighten all Bolts from Details A B C DO NOT OVERTIGHTEN After the boom is installed attach the 8 Feeder Hose to the 90 HB Elbow on the manifold The boom is now installed Locate the Pressure Gauge in ...

Страница 5: ...n disconnect the negative black connection and finally the positive red connection The lead wire has an On Off switch to activate the pump is on and O is off Fill the tank part way with water and then add the desired amount of chemical to be sprayed Finish filling tank to proper level Turn the pump on and by depressing the side of the rock er switch The pump is equipped with a pressure switch that...

Страница 6: ...cturer s instructions on disposal of all waste water from the sprayer Winter Storage Prepare the sprayer for end of season storage by running RV antifreeze through the system This will keep internal parts lubricated protect against corrosion and keep the unit from freezing Note RV antifreeze is non toxic and biodegradable and generally safer for the environment than automotive antifreeze Before st...

Страница 7: ... defective check valve Check for clogged strainer filter Check for cracks in the pump housing Check for empty product supply Low Pressure Low Flow Check for leaks in the discharge line Check for restriction in the discharge line Check for debris in nozzle orifice Check for clogged strainer Check for proper voltage try another 12 volt battery Pulsating flow surging Low flow may cause pump to surge ...

Страница 8: ...an hour or so in the hot soapy solution and replace in the pump and reassemble the pump Most times this will restore most if not all of the prime of a pump If you re still having issues with pressure after this step it would be recommended to replace this part Checking the Pressure Switch If your motor is not running and you ve checked the following for loose wiring connections fuse the switch on ...

Страница 9: ...Page 9 See Intake Assembly Detail Page 11 See Manifold Assembly Detail Page 11 See Boom Assembly Parts List Next Page Exploded View Parts List LG 30 TRL 5302317 ...

Страница 10: ...0 spacing Suggested Minimum Spray Height 18 20 above what is being sprayed to plant not ground Optimum Spray Height 39 Wide angle spray nozzle height is influenced by nozzle orientation The critical factor is to achieve a minimum 30 overlap Excellent spray distribution for uniform coverage along the boom Nozzle design incorporates a pre orifice to pro duce larger droplets for less drift ...

Страница 11: ...mbly 5281537 Intake Assembly 5278143 This sprayer comes with an On Off shut off valve located at the inlet location of the tank towards the underside You must make sure the valve is in the open position before using your sprayer ...

Страница 12: ...obtain warranty service under this Limited Warranty you must 1 provide written notice to Fimco Ind of the defect during the Warranty Period and within thirty 30 days after the defect becomes apparent or the repair becomes necessary at the following address Fimco Ind 1000 Fimco Lane North Sioux City SD 57049 and 2 make the Equipment available to Fimco Ind or an authorized dealer within a reasonable...

Отзывы: