Fimco 5302317 Скачать руководство пользователя страница 1

Page 1 

 

Model: LG-30-TRL (5302317) 

(30 Gallon Lawn & Garden Trailer Sprayer

)

 

www.fimcoindustries.com 

1000 FIMCO Lane, P.O. Box 1700, North Sioux City, SD  57049      

Toll Free Phone: 800-831-0027 : Toll Free Fax: 800-494-0440 

[5194822   

 

 

 

 

 

(02/20)] 

Technical Specifications 

 

30 Gal. Corrosion-Resistant Polyethylene Tank 

 

12 Volt Diaphragm Pump, 2.4 GPM - 60 PSI 

 

15 Ft. Handgun Hose 

 

25 Ft. max. vertical throw, 40 Ft. horizontal throw 

 

2-Nozzle Break-Away Boom Assembly (80” Spray Coverage) 

 

Corrosion-Resistant Nylon Nozzles 

 

Check Valve Strainers, 50 Mesh, 5 PSI 

 

Easy access drainage port (Complete Drain Out) 

 

Front forward gun and hose wrap for easier access from 
transport vehicle 

 

Heavy Duty 16” tires 

 

Wide Axle 

 

Streamlined tank design for compact storage and 

 

  shorter turning radius 

 

Caution:  Always  check  the  vehicle  load  rating  before  using 

the  sprayer.  The  loaded  weight  of  this  sprayer  and  boom 

assembly is approx.: 320 lbs. when the tank is full.  

Assembly Instructions 

 Make  sure  the  contents  of  the  sprayers  carton  match  the 

items shown on page 2 of the manual. 

 

 Follow the steps on pages 3 & 4 to properly assemble the 

sprayer. 

IMPORTANT: 

This sprayer comes with 

an On/Off (shut-off) valve 

located at the inlet location 

of the tank, towards the 

underside. You must make 

sure the valve is in the 

“open” position before  

using your sprayer. 

OWNER’S MANUAL

 

BEFORE RETURNING THIS PRODUCT

FOR ANY REASON, PLEASE CALL

1-800-831-0027

MONDAY-FRIDAY, 8:00 AM TO 5:00 PM CST

If you should have a question or experience a problem with

your Fimco Industries Product: Visit our website @ 

www.fimcoindustries.com or call the Toll free number above. Our 

technical support representatives will be happy to help you. 

In most cases a customer service rep. can resolve

the problem over the phone.

To obtain prompt, efficient service, always remember to give the 

following information....

• Correct Part Description and/or part number

• Model number and Serial Number

Part descriptions and numbers can be obtained from the

illustrated parts list section(s) of this manual.

General Information 

Thank you for purchasing this product. The purpose of this 

manual is to assist you in operating and maintaining your lawn 

& garden Trailer sprayer.  

Retain a copy of your receipt for your 

unit, as it will be required to validate 

any warranty service. 

 

Warranted against manufacturer or 

workmanship defects from date of 

purchase with copy of receipt: 

 

Homeowner Usage: Sprayer-One Year and Pump-Two Years. 

 

Commercial Usage: Sprayer and Pump-90 Days.

 

Содержание 5302317

Страница 1: ...On Off shut off valve located at the inlet location of the tank towards the underside You must make sure the valve is in the open position before using your sprayer OWNER S MANUAL BEFORE RETURNING THIS PRODUCT FOR ANY REASON PLEASE CALL 1 800 831 0027 MONDAY FRIDAY 8 00 AM TO 5 00 PM CST If you should have a question or experience a problem with your Fimco Industries Product Visit our website www ...

Страница 2: ...Page 2 Tires Contents of your sprayer s carton LG 30 TRL Tank Plumbing Pre Assembly Owner s Manual Contents of Parts Bag 5278364 Breakaway Boom Bracket Kit LG 30 TRL 5278366 Tongue Assembly ...

Страница 3: ...6 x 2 1 4 Flanged bolts tank support axle support and the preassembled tongue Turn the tank upside down Detail A Loosely attach the tank support and axle support with 4 lock screws Just start the bolts do not tighten on either support Detail B Slide the tongue assembly into place and using the 2 flanged bolts attach to the tank and tighten Do Not Overtighten Then tighten the 4 lock screws Do Not O...

Страница 4: ...ank using the two screws DO NOT TIGHTEN Detail C Locate in the parts bag 2 5 16 18 x 5 8 Flanged Bolts and 2 Whiz Nuts Attach the Boom Top Straps to the Boom Assembly using the two bolts and whiz nuts Tighten all Bolts from Details A B C DO NOT OVERTIGHTEN After the boom is installed attach the 8 Feeder Hose to the 90 HB Elbow on the manifold The boom is now installed Locate the Pressure Gauge in ...

Страница 5: ...n disconnect the negative black connection and finally the positive red connection The lead wire has an On Off switch to activate the pump is on and O is off Fill the tank part way with water and then add the desired amount of chemical to be sprayed Finish filling tank to proper level Turn the pump on and by depressing the side of the rock er switch The pump is equipped with a pressure switch that...

Страница 6: ...cturer s instructions on disposal of all waste water from the sprayer Winter Storage Prepare the sprayer for end of season storage by running RV antifreeze through the system This will keep internal parts lubricated protect against corrosion and keep the unit from freezing Note RV antifreeze is non toxic and biodegradable and generally safer for the environment than automotive antifreeze Before st...

Страница 7: ... defective check valve Check for clogged strainer filter Check for cracks in the pump housing Check for empty product supply Low Pressure Low Flow Check for leaks in the discharge line Check for restriction in the discharge line Check for debris in nozzle orifice Check for clogged strainer Check for proper voltage try another 12 volt battery Pulsating flow surging Low flow may cause pump to surge ...

Страница 8: ...an hour or so in the hot soapy solution and replace in the pump and reassemble the pump Most times this will restore most if not all of the prime of a pump If you re still having issues with pressure after this step it would be recommended to replace this part Checking the Pressure Switch If your motor is not running and you ve checked the following for loose wiring connections fuse the switch on ...

Страница 9: ...Page 9 See Intake Assembly Detail Page 11 See Manifold Assembly Detail Page 11 See Boom Assembly Parts List Next Page Exploded View Parts List LG 30 TRL 5302317 ...

Страница 10: ...0 spacing Suggested Minimum Spray Height 18 20 above what is being sprayed to plant not ground Optimum Spray Height 39 Wide angle spray nozzle height is influenced by nozzle orientation The critical factor is to achieve a minimum 30 overlap Excellent spray distribution for uniform coverage along the boom Nozzle design incorporates a pre orifice to pro duce larger droplets for less drift ...

Страница 11: ...mbly 5281537 Intake Assembly 5278143 This sprayer comes with an On Off shut off valve located at the inlet location of the tank towards the underside You must make sure the valve is in the open position before using your sprayer ...

Страница 12: ...obtain warranty service under this Limited Warranty you must 1 provide written notice to Fimco Ind of the defect during the Warranty Period and within thirty 30 days after the defect becomes apparent or the repair becomes necessary at the following address Fimco Ind 1000 Fimco Lane North Sioux City SD 57049 and 2 make the Equipment available to Fimco Ind or an authorized dealer within a reasonable...

Отзывы: