Fimap GENIE E Скачать руководство пользователя страница 10

 

 

 
10

PREPARATION OF MACHINE 

 

 

 

 

ATTENTION: Acid or alkaline maintenance detergent can be used with pH 
values between 4 and 10 and that do not contain: oxidising agents, chlorine or 
bromine, formaldehyde, mineral solvents. 

 

 
 

 

 

 

 

ATTENTION: Always use detergents whose manufacturer's label indicates 
their suitability for scrubbing machines. Do not use acid or alkaline products or 
solvents without this indication. 
always use low-foam detergent. To avoid the production of foam, put a 
minimum quantity of antifoam liquid in the recovery tank before starting to 
clean. Do not use pure acids

 

 

 

 

 

 

ATTENTION: 

users are advised to always wear protective gloves, to avoid 

the risk of serious injury to hands.

 

 

 

 

 

9. RECOVERY 

TANK 

Make sure the recovery tank is empty, otherwise empty it completely. 
Verify that the recovery tank is correctly inserted in its housing, and that the tubes are correctly inserted 
in the tank elbows. 
Verify that the caps are correctly closed. 

 

 

 

10.  ASSEMBLING THE BRUSH 

To insert the brush: 
 
1.

 

Connect the machine to the mains power supply 

2.

 

Place the brush in front of the base body 

3.

 

Raise the brush head by using the handlebars as a lever 

4.

 

Place the brush head above the brush 

5.

 

Activate the handlebar tilt lever 

6.

 

Press the main switch to turn on the machine 

7.

 

Pulse press the dead man's lever to engage the brush to the brush head 

 

 

 

 

 

Содержание GENIE E

Страница 1: ...USE AND MAINTENANCE MANUAL GENIE E ED 09 2019 ENG ORIGINAL INSTRUCTIONS Doc 10004515 Ver AC...

Страница 2: ...ny technical and or supply modifications The images are for reference purposes only and are not binding in terms of design and supply Symbols used in the manual Open book symbol with an i Indicates th...

Страница 3: ...SH 10 WORK 11 1 PREPARING TO WORK 11 2 OVERFLOW DEVICE 11 3 FORWARD MOVEMENT 12 AT THE END OF THE WORK 13 DAILY MAINTENANCE 14 1 CLEANING THE RECOVERY TANK 14 2 EMPTYING THE SOLUTION TANK 14 3 CLEANIN...

Страница 4: ...removed as well as any detergent solution not absorbed by the floor The machine must only be used for this purpose Even the best machines will only work well if used correctly and kept in good working...

Страница 5: ...gradient 2 2 Suction motor Rated voltage V Hz 230 50 110 50 Vacuum motor Rated power W 220 220 Maximum vacuum IEC 62885 9 IEC 60312 1 kPa 7 2 7 2 Solution tank l 7 7 Recovery tank l 9 9 Dimensions of...

Страница 6: ...symbol Used on the control handlebars to indicate the switch that controls the machine s suction motor Symbol for maximum temperature for filling the solution tank Used near the solution tank filling...

Страница 7: ...using the machine please read the following document carefully and follow the instructions contained herein along with the instructions in the document supplied with the machine itself GENERAL SAFETY...

Страница 8: ...hout effort even in small vehicles Just lift the front part using the machine handlebars as a lever The big rear wheels mean it can be towed anywhere and loaded on a truck by means of a simple ramp Ge...

Страница 9: ...etely empty each time the solution tank is filled Verify that the cap is correctly inserted in its housing A Verify that the quick connection is correctly connected B 8 DETERGENT SOLUTION Proceed as f...

Страница 10: ...re acids ATTENTION users are advised to always wear protective gloves to avoid the risk of serious injury to hands 9 RECOVERY TANK Make sure the recovery tank is empty otherwise empty it completely Ve...

Страница 11: ...on 4 Carry out the operations to prepare the machine 5 lower the squeegee command lever in order to start working 4 press the main switch 1 and verify that the green indicator light comes on 5 press t...

Страница 12: ...y means of the brush which by working slightly inclined is able to drag the machine forwards ATTENTION Ensure that the moving brush never comes into contact with the power supply cable ATTENTION when...

Страница 13: ...the mains socket 6 Take the machine to the location designated for draining the water 7 Disconnect the suction pipes 8 Disconnect the hook securing the recovery tank on the rear of the machine 9 Remo...

Страница 14: ...power supply cable 5 Remove the caps to open the tank 6 Clean the filter under running water 7 Rinse the tank and clean with a jet of water ATTENTION This operation must be carried out wearing gloves...

Страница 15: ...f maintenance disconnect the machine s power supply cable 4 REPLACING THE SQUEEGEE RUBBERS Verify that the state of wear and tear of the squeegee rubbers and if necessary replace them To replace it yo...

Страница 16: ...ntact with dangerous solutions ATTENTION Before carrying out any type of maintenance disconnect the machine s power supply cable 5 DISASSEMBLING THE BRUSH 1 raise the squeegee 2 Raise the machine by u...

Страница 17: ...lows either periodically or if inadequate water is emitted 1 Disconnect the machine from the mains power supply 2 Disconnect the suction pipes 3 Remove the recovery tank retainer 4 Remove the recovery...

Страница 18: ...the vent pin on the solution tank cap is lowered 3 THE MACHINE DOES NOT CLEAN WELL 1 Check the state of wear and tear of the brushes and if necessary replace them The brushes should be changed when th...

Страница 19: ...ocking system in plastic that allows the abrasive floor pads to be perfectly centred and held without any risk of them becoming detached 1 fitted with a series of anchor points that allow the abrasive...

Страница 20: ...20 MACHINE DISPOSAL Proceed with scrapping the machine in accordance with the waste disposal regulations in force in the country in which the machine is being used...

Страница 21: ...2014 35 EU Low Voltage Directive 2014 30 EU Electromagnetic compatibility directive They also comply with the following standards EN 60335 1 2012 A11 2014 EN 60335 2 72 2012 EN 12100 2010 EN 61000 3...

Страница 22: ...22...

Страница 23: ......

Страница 24: ...FIMAP Via Invalidi del Lavoro 1 37059 S Maria di Zevio Verona Italy Tel 39 045 6060411 Fax 39 045 6060417 E mail fimap fimap com www fimap com...

Отзывы: