PREPARATION OF MACHINE
ATTENTION: Acid or alkaline maintenance detergent can be used with pH
values between 4 and 10 and that do not contain: oxidising agents, chlorine or
bromine, formaldehyde, mineral solvents.
ATTENTION: Always use detergents whose manufacturer's label indicates
their suitability for scrubbing machines. Do not use acid or alkaline products or
solvents without this indication.
always use low-foam detergent. To avoid the production of foam, put a
minimum quantity of antifoam liquid in the recovery tank before starting to
clean. Do not use pure acids.
ATTENTION:
users are advised to always wear protective gloves, to avoid
the risk of serious injury to hands.
9. RECOVERY
TANK
Make sure the recovery tank is empty, otherwise empty it completely.
Verify that the recovery tank is correctly inserted in its housing, and that the tubes are correctly inserted
in the tank elbows.
Verify that the caps are correctly closed.
10. ASSEMBLING THE BRUSH
To insert the brush:
1.
Connect the machine to the mains power supply
2.
Place the brush in front of the base body
3.
Raise the brush head by using the handlebars as a lever
4.
Place the brush head above the brush
5.
Activate the handlebar tilt lever
6.
Press the main switch to turn on the machine
7.
Pulse press the dead man's lever to engage the brush to the brush head