Translation of the original instructions with assembly instructions AF 73 - 76 S/AF 93 - 96 S, Filtration Group GmbH, 11.07.19,
Mat. No. 79301615, Version 13
9.1
Mechanical installation
DANGER!
Explosion hazard!
Risk of injury to persons or damage to
property.
Check the conductivity between all
components!
Note the maximum permissible resistance:
R < 10
.
Make sure that earthing is provided by the
customer.
It must be possible to remove the filter insert
in order to carry out maintenance work.
Prepare a suitable seat on which to mount the filter
(e.g. supports).
Be sure to allow the required height for dismantling and
draining (see data sheet).
Replace two opposite screws at the flange cover of the
metal-edge filter by lifting screws.
Lift metal-edge filter at the lifting screws out of packaging.
Bolt the metal-edge filter to the prepared seat.
Remove the caps from the connections.
Connect the pipes.
Pressure relief
Design measures must be incorporated to prevent
inadmissible excess pressure on the dirty side.
Install a pressure relief device if necessary.
Fig. 6: Mechanical installation
9.2
Special mounting instructions for the drain
pipe
WARNING!
The full inlet pressure is present at the drain valve!
Make sure that the drain pipe is securely fastened.
Do not drain concentrate into the atmosphere.
Provide splash protection if necessary.
Lay the pipes without a syphon if possible.
Watch out for clogging as a result of sedimented
concentrate!
9.3
Electro-pneumatic connections
DANGER!
Danger of electric shock!
Risk of serious or fatal injury in case of
contact with electrical components.
All electrical installation work must be
carried out by a suitably qualified
electrician.
9.3.1 Connection to customer's control
Gear motor
See the rating plate or the contract documentation for the
connection data (please also refer to the connection
diagram for the terminal box).
Connect the gear motor .
Provide adequate protection for the motor.
Fig. 7: Connection of the standard gear motor
Differential pressure switch (optional)
Refer to the enclosed manufacturer’s documentation for
details of the connections.
Automatic drain valve (optional)
Provide a suitable compressed air supply.
Provide a suitable 5/2-way valve for pilot control.
Refer to the contract documentation for
special types.
Dismantling height
Draining height
(400 -600 mm)
Filtrate
Inlet
Drain
400V 3~ 230V 3~