6
•
Loosen the hexagon screws (12) and remove them
together with the spring washers (13).
•
Withdraw the backflush adapter housing (30.1) from the
cover (7).
Fig. 40:
Withdrawing the backflush adapter housing
7
•
Remove the O-ring (75.5).
Fig. 41:
Removing the O-ring
8
•
Remove the bearing bushes (55.1).
Fig. 42:
Removing the bearing bushes
9
•
Clean the shaft seal attachment, drive shaft and
backflush adapter.
•
Oil the new sealing and guiding elements lightly and
install them.
•
Install in reverse order.
After installing:
•
Screw in the hexagon screws (25) hand-tight.
•
Turn the drive shaft (17) slightly and pull it up.
•
Tighten the hexagon screws (25).