Connect source water feed tubing to valve body using compression fitting.
a.
Slide nut and sleeve onto tubing.
b.
Install insert into plastic tubing
c.
Install tube with insert and sleeve into valve body.
d.
Thread compression nut onto valve body, tighten.
e.
Turn saddle-tapping valve handle clockwise until it is firmly seated and piercing lance is fully
extended.
Sanitizing the System
:
Disconnect the power supply from the cooler.
•
Drain hot/cold water tank and water from the reservoir.
•
Drain water fro reservoir and hot tank (if fitted) through the faucets.
•
Put on disposable gloves and wash the faucets using mild cleaning agent. Parts must be
completely submerged in the solution. Rinse with clean water immediately.
•
Reassemble the water cooler using the sanitized components.
•
Sanitize hot and cold tank (if fitted) and entire cooler with a new batch of sanitizing solution.
•
Completely fill the cooler with sanitizing solution, and let stand for 5 minutes.
•
Drain solution through hot and cold tank drain (if fitted), or through faucets.
•
Rinse with clean water immediately.
•
Reconnect the cold supply line to cooler’s inlet tube.
•
Flush the reservoir at least three times to remove any traces of the sanitization solution.
•
Use chlorine test kit to identify the presence of any contaminants.
•
If contamination still exists, flush the reservoir and use chlorine test kit again.
•
Clean the outside of the cabinet and the drip tray using a mild cleaning agent.
•
Reconnect the power supply to the cooler.