21 |
P a g e
Reverse Osmosis Membrane Replacement
RO versions (RO)
(every 3 years)
a)
Use the same procedure as above sec a-c.
b)
Remove the RO stage from the clips. Disconnect the white
tubing from the RO housing cap.
c)
Remove the cap from the housing by unscrewing it.
d)
Using a pair of pliers, remove the RO element from the
housing by grasping the tube end and pulling it out.
e)
Use RO filter replacement P/N CSM50 (50gpd). Insert the
element into the housing with double “o”-ring end going in
first–toward the bottom of the housing. Make sure the “o”-
rings are sealed. Replace the cap. Reconnect the white tubing.
Proceed as in above sec. g.
Figure. 8
RO Membrane Installation