Exploded view table 

Nº  

DENOMINATION 

MODÈLES HYDRAULIC-200-H MODELS 

HYDRAULIC 204-H 

HYDRAULIC 206-H 

HYDRAULIC 208-H 

HYDRAULIC 210-H 

U.

 

Code 

U.

 

Code 

U.

 

Code 

U.

 

Code 

Calibrated Orifice 

HYD-206-H-06-06 

HYD-206-H-06-06 

HYD-206-H-06-06 

HYD-206-H-06-06 

Calibrated Orifice Cap 

HYD-206-H-06-03 

HYD-206-H-06-03 

HYD-206-H-06-03 

HYD-206-H-06-03 

Gasket 1 

Cylinder Liners 

HYD-206-H-06-04 

HYD-206-H-06-04 

HYD-206-H-06-04 

HYD-206-H-06-04 

Piston Guide Ring 

Gasket 2 

Piston 

HYD-206-H-06-04 

HYD-206-H-06-04 

HYD-206-H-06-04 

HYD-206-H-06-04 

Gasket 3 

Gasket 4 

10 

Gasket 5 

11 

Piston Cap 

HYD-206-H-06-02 

HYD-206-H-06-02 

HYD-206-H-06-02 

HYD-206-H-06-02 

12 

Stem 

HYD-206-H-06-01 

HYD-206-H-06-01 

HYD-206-H-06-01 

HYD-206-H-06-01 

13 

Grinding Side Cap 

HYD-206-H-08-00 

HYD-206-H-08-00 

HYD-206-H-08-00 

HYD-206-H-08-00 

14 

Pressure Gauge 

15 

Gasket 6 

16 

Casing 

HYD-204-H-02 

HYD-206-H-02 

HYD-208-H-02 

HYD-210-H-02 

17 

Suction Cup 1’’

 

18 

Ball Valve 

19 

Cylinder Side Cap 

HYD-206-H-07-00 

HYD-206-H-07-00 

HYD-206-H-07-00 

HYD-206-H-07-00 

20 

Valve 

21 

Victaulic Flange 2’’

 

22 

Black handle 

23 

Hydraulic relay 

24 

Steel T Fitting 

25 

Solenoid 

26 

Electrical panel 
support 

HYD-206-H-02-06 

HYD-206-H-02-06 

HYD-206-02-06 

HYD-206-H-02-06 

27 

Programmer 

28 

Filter Cartridge 

HYD-204-H-04-00 

HYD-206-H-04-00 

HYD-208-H-04-00 

HYD-210-H-04-00 

29 

Centering Disk 

HYD-206-H-05-07 

HYD-206-H-05-07 

HYD-206-H-05-07 

HYD-206-H-05-07 

30 

PVC Screw 

31 

Grinding Gasket 
Cartridge  

HYD-206-H-03-04 

HYD-206-H-03-04 

HYD-206-H-03-04 

HYD-206-H-03-04 

32 

Gasket between 
Cartridges 

HYD-206-H-05-06 

HYD-206-H-05-06 

HYD-206-H-05-06 

HYD-206-H-05-06 

33 

Grinding Cartridge 

HYD-206-H-03-00 

HYD-206-H-03-00 

HYD-206-H-03-00 

HYD-206-H-03-00 

34 

Stainless bushing 

HYD-206-H-07-05 

HYD-206-H-07-05 

HYD-206-H-07-05 

HYD-206-H-07-05 

35 

Squared Gasket 

HYD-206-H-07-04 

HYD-206-H-07-04 

HYD-206-H-07-04 

HYD-206-H-07-04 

36 

PVC Pipe 

HYD-206-H-05-04 

HYD-206-H-05-04 

HYD-206-H-05-04 

HYD-206-H-05-04 

37 

Turning screw 

HYD-206-H-05-1-4 

HYD-206-H-05-1-4 

HYD-206-H-05-1-4 

HYD-206-H-05-1-4 

38 

Turbine cap 

HYD-206-H-05-1-2 

HYD-206-H-05-1-2 

HYD-206-H-05-1-2 

HYD-206-H-05-1-2 

39 

Hex nut 

40 

Guide Bushing 

HYD-206-H-05-10 

HYD-206-H-05-10 

HYD-206-H-05-10 

HYD-206-H-05-10 

41 

Cleaning Chamber 
Disk 

HYD-206-H-05-02 

HYD-206-H-05-02 

HYD-206-H-05-02 

HYD-206-H-05-02 

42 

Gasket Disk C.L. 

HYD-206-H-05-2-2 

HYD-206-H-05-2-2 

43 

Scanner 

HYD-204-H-05-00 

HYD-206-H-05-00 

HYD-208-H-05-00 

HYD-210-H-05-00 

 

T

ABLE 

 

*Screws for the grinding side cap (nº13) and cylinder side cap (nº19) 

 

Closing hardware: 

-Hexagonal screw M16x60 DIN933. 16 U. 

-Hexagonal nut M16 DIN934. 16 U. 

-Flat washer D16 DIN125. 32 U. 

 

Hinge hardware: 

-Hexagonal screw M16x60 DIN933. 4 U. 

-Nylon washer M10 DIN125. 8 U. 

-Brake nut M10 DIN985. 

U

SER 

M

ANUAL 

HYDRAULIC-200-H 

9

Содержание HYDRAULIC-200-H

Страница 1: ...www itmfilters com Self cleaning Mesh Filter User manual HYDRAULIC 200 H Serial number _________________ Purchase date _________________...

Страница 2: ...3 Exploded view table 9 7 Control panel 10 7 1 Features listing 10 7 2 How to program the controller 11 7 3 The chain of editable fields 11 7 4 Wash time 12 7 5 DP preset value 12 7 6 Wash mode 12 7...

Страница 3: ...eplate 1 2 Basic concepts Filtration surface Area that allows water to pass while retaining suspended particles Recommended flow Optimal filtration must take into account the quality of the source wat...

Страница 4: ...dance with the applicable European Directives Directive 2006 42 CE on Machines Annex IIA Directive 2014 68 EU on Pressure Equipment and Directive 2014 35 EU on Electrical Material These quality requir...

Страница 5: ...ge 10 585 323 273 195 14135 235 177 HYDRAULIC 212 H COMPACT Flange 12 645 355 300 215 14135 235 181 TABLE 1 Manufacturing technical characteristics Materials o Carbon steel metal components o Zinc pla...

Страница 6: ...C 206 H 355 1455 352 900 203 1865 400 1300 HYDRAULIC 208 H COMPACT 355 1455 352 900 203 1865 400 1300 HYDRAULIC 208 H 355 1741 438 1100 203 2150 400 1585 HYDRAULIC 210 H COMPACT 355 1741 438 1100 203...

Страница 7: ...operation with automatic cleaning OPEN cleaning cycle CLOSE filter operation without automatic cleaning USER MANUAL HYDRAULIC 200 H 5 IMAGE 4 SOLENOID CALIBRATED ORIFICE HYD REL MANUAL ACTUATOR SUCTIO...

Страница 8: ...ge When the mesh filter becomes clogged it produces a pressure difference between the inlet and outlet manifolds The automatic cleaning cycle starts when it reaches a pressure difference of 0 3 kg cm...

Страница 9: ...nology used in the manufacture of the HYDRAULIC 200 H filter offers high filtration surfaces with compact lengths due to the maximization of the filter cartridge 6 Maintenance and spare parts 6 1 Main...

Страница 10: ...ilters com you can find a video tutorial with the maintenance process 6 2 Exploded view USER MANUAL HYDRAULIC 200 H 8 23 25 24 20 30 29 28 27 26 33 32 31 34 17 22 21 1 2 3 4 5 6 7 3 8 9 11 10 12 13 15...

Страница 11: ...rogrammer 1 1 1 1 28 Filter Cartridge 1 HYD 204 H 04 00 1 HYD 206 H 04 00 1 HYD 208 H 04 00 1 HYD 210 H 04 00 29 Centering Disk 1 HYD 206 H 05 07 1 HYD 206 H 05 07 1 HYD 206 H 05 07 1 HYD 206 H 05 07...

Страница 12: ...ump The AC model contains an internal transformer that can be powered by 110V or 220V from which 24v AC is generated for the solenoids The wash cycles can be triggered either by time or by means of th...

Страница 13: ...ntered the user will not be able to go back and must keep pressing the ENTER key repeatedly to go through the chain of editable fields until reaching the WASH TIME field again Please note that before...

Страница 14: ...ash cycles will be triggered The options are as follows OFF There will be no washing By time In this case the wash cycles will be repeated at a selected interval or triggered by the DP signal dependin...

Страница 15: ...roblem The options are 1 10 or no which means to ignore the loop problem Yes No assigning an output for alarm activation Yes No assigning an output for Delay Valve activation This is a special mode th...

Страница 16: ...start from the beginning instead of continuing from the stop point 7 11 Connecting the DP sensor to the filter system The DP sensor is connected to the filter system by 2 command tubes one that comes...

Страница 17: ...www itmfilters com 7 14 Timing diagram Without delay valve With delay valve Main valve Valve 1 Valve 2...

Страница 18: ...The external DP sensor is optional and is intended to be used in cases where the integrated electronic DP sensor is not included 2 The unit can be powered by 6v DC or 12v DC 3 The solenoids are 12v D...

Страница 19: ...ensor is optional and is intended to be used in cases where the integrated electronic PD sensor is not included 2 The unit is powered by 24v AC transformed from 220 110 v AC 3 In the solenoids it will...

Страница 20: ...ted analog electronic DP sensor or external dry contact DP sensor Pressure sensor Dry contact pressure sensor Operating temperature AC model 0 60 C Power source 220 or 110 v AC 50 or 60 Hz with includ...

Страница 21: ...ablished quality or is outside the specifications indicated in the technical tables vi A use of flow discordant with the water quality according to the parameters defined in the technical tables vii P...

Страница 22: ...www itmfilters com INTRAMESA MZ S A Pol gono Armentera P 99 22400 Monz n Huesca www itmfilters com info itmfilters com Tel 974 10 50 05...

Отзывы: