NOTE: Torque values in Appendix A are based on a nut factor K = 0.2. Adjustments to the torque should be considered
if the installation utilizes bolting/lubrication with a nut factor other than K = 0.2. The following expression may be used
for correction:
Equation 1: T
2
= (T
1
/K
1
) * K
2
where T
1
and K
1
are the Fike default torque and nut factor values.