Sector
Contents
Page
1
Safety Instructions
5
1.1
Prerequisites for the utilisation of the safety light curtains
5
2
Terminology
6
3
System Description and Technical Data
8
3.1
Features
8
3.2
Application Areas
8
3.3
Structure and Function
9
3.4
Tables:
Protective fields
,
constructional lengths, ranges, resolutions, beam spacing, number of beams
9
3.5
LED-displays (in general)
10
3.6
Operating modes selector
(with/without restart interlock, with/without contactor check, equivalent/antivalent outputs)
10
3.7
Technical data
11
3.8
Dimensions drawing (
Light curtain and standard fastening brackets)
12
4
Installation
13
4.1
Response times
ULVT, BLVT, cascaded systems and optional safety switching units
13
4.2
Safety distance
from the hazardous areas
14
4.2.1
- vertical protection for hazardous areas
(
≤
40 mm resolution)
14
4.2.2
- horizontal protection for hazardous areas
15
4.2.3
- vertical protection for hazardous areas by light grids
(> 40 mm resolutiion and single beams)
16
4.3
Construction requirements
17
4.3.1
- Installation without additional screening
17
4.3.2
- Protection against reaching over or under barriers
17
4.3.3
- Protection against avoiding barriers through cascading or additional screening
17
4.3.4
- Distance from reflective surfaces
18
4.3.5
- Arrangement of two safety light barriers
18
4.4
Mounting and Adjustment
19
4.4.1
Adjustment Instructions with standard fastening brackets / Isolated mounting on EMV disturbances
19
4.4.2
Option: angular brackets
(dimension drawing included)
20
4.4.3
Option: rubber-metal connection (to avoid intense vibrations)
21
4.4.4
Option: multi-sided screening by using tilted mirrors
(dimension drawing included)
21
4.4.5
Option: Assembly columns / Shock Protection
(dimension drawing included)
23
5
Electric Connection ULVT / BLVT
25
5.1
Integrated connector plug
25
5.2
Electric connection ratings
25
5.3
Connectors
25
5.4
Connection examples - without optional safety switching units
26
5.4.1
ULVT 500/2R
: connecting advice
26
5.4.2
Safety mode with restart interlock/ with valve or contactor check
26
5.4.3
Safety mode without restart interlock/ without valve or contactor check
26
5.4.4
SPS drive
26
6
Commissioning
27
6.1
Commissioning
27
6.2
Adjustment instructions / LED-displays
27
6.3
Trouble-shooting / LED-displays
28
chapters 7 ... 11
--->>
Table of contents
FIESSLER
E L E K T R O N I K
3
Fiessler Elektronik GmbH & Co. KG
Doku Nr. 958 Stand 22.01.2018 RK
Phone: +49 (0) 711 / 91 96 97-0 Internet: http://www.fiessler.de