FS-8704-16 Omron FINS Manual
Table of Contents
FieldServer Technologies
1991 Tarob Court Milpitas, California 95035 USA
Web
:www.fieldserver.com
Tel
: (408) 262-2299
Fax
: (408) 262-9042
Toll_Free
: 888-509-1970
TABLE OF CONTENTS
1.
Omron FINS Description...................................................................................... 1
2.
Driver Scope of Supply ........................................................................................ 2
1.01 Supplied by FieldServer Technologies for this driver ....................................... 2
1.02 Provided by the Supplier of 3
rd
Party Equipment.............................................. 2
2.1.1.
Required 3
rd
Party Hardware ......................................................................... 2
2.1.2.
Required 3
rd
Party Software .......................................................................... 2
2.1.3.
Required 3
rd
Party Configuration ................................................................... 2
3.
Hardware Connections ........................................................................................ 3
1.03 Hardware
Connection Tips / Hints.................................................................... 3
1.04 Example of Omron PLC Configuration using Omron ETN11 Module. .............. 4
4.
Configuring the FieldServer as a FINS Client .................................................... 6
1.05 Data
Arrays/Descriptors ................................................................................... 6
1.06 Driver Specific FieldServer Parameters ........................................................... 7
1.07 Client
Side
Connection Descriptors.................................................................. 7
1.08 Client
Side
Node
Descriptors ........................................................................... 8
1.09 Client
Side
Map Descriptors ............................................................................. 9
4.1.1.
FieldServer Related Map Descriptor Parameters .......................................... 9
4.1.2.
Driver Related Map Descriptor Parameters................................................... 9
4.1.3.
Timing Parameters ...................................................................................... 10
4.1.4.
Map Descriptor Example 1 – IO Read ......................................................... 11
4.1.5.
Map Descriptor Example 2 – IO Write ......................................................... 12
4.1.6.
Map Descriptor Example 3: Clock Read:..................................................... 13
4.1.7.
Map Descriptor Example 4: Clock Write: ..................................................... 13
4.1.8.
Map Descriptor Example 5: Read CPU Cycle Times: ................................. 13
4.1.9.
Map Descriptor Example 6: Run-Stop PLC: ................................................ 14
4.1.10.
Map Descriptor Example 7: Read CPU Status: ........................................ 14
5.
Configuring the FieldServer as a FINS Server ................................................. 15
1.010 Server Side Connection Descriptors .............................................................. 15
1.011 Server Side Node Descriptors ........................................................................ 16
1.012 Server Side Map Descriptors.......................................................................... 17
5.1.1.
FieldServer Specific Map Descriptor Parameters........................................ 17
5.1.2.
Driver Specific Map Descriptor Parameters................................................. 17
5.1.3.
Map Descriptor Example 1: IO Read ........................................................... 18
5.1.4.
Map Descriptor Example 2: IO Write ........................................................... 19
5.1.5.
Map Descriptor Example 3: Clock Read:..................................................... 19
5.1.6.
Map Descriptor Example 4: Clock Write: ..................................................... 19
5.1.7.
Map Descriptor Example 5: CPU Cycle Times: ........................................... 19
5.1.8.
Map Descriptor Example 6: Run-Stop PLC: ................................................ 20
5.1.9.
Map Descriptor Example 7: CPU Status:..................................................... 20
Appendix A.
Advanced Topics ................................................................................ 21
Appendix A.1. Driver Map Descriptor Parameter’s Bounds ..................................... 21