System Trouble         

Address 

 

System Trouble         

Address 

LOOP CONTINUITY TEST FAIL LOOP 3            

231 

 

WALK TEST - FIRE PROTECTION IS LIMITED      

485 

LOOP CONTINUITY TEST FAIL LOOP 4            

232 

 

REMOTE PROG MODE ACCESSED                   

486 

LOOP CONTINUITY TEST FAIL LOOP 5            

233 

 

DIA PROG. CHANGE DET. SERVICE REQUIRED      

487 

LOOP CONTINUITY TEST FAIL LOOP 6            

234 

 

ISIB DATA MESSAGE RECEIVED ERROR            

488 

LOOP CONTINUITY TEST FAIL LOOP 7            

235 

 

ISIB EXECUTIVE ROUTINE RE-ENTERED           

489 

LOOP CONTINUITY TEST FAIL LOOP 8            

236 

 

DIB TO SIB CABLE BAD OR MISSING             

490 

LOOP CONTINUITY TEST FAIL LOOP 9            

237 

 

UPLOAD/DOWNLOAD MESSAGE RECEIVED            

491 

LOOP CONTINUITY TEST FAIL LOOP 10           

238 

 

GLOBAL DATABASE MISMATCH                    

492 

AMP FAIL                                    

239 

 

SIB PROG. CHANGE DET. SERVICE REQUIRED      

493 

AC FAIL                                     

240 

 

HS-NCM SNIFFER MODE ACTIVE                  

494 

SCB ASSEM. COM. VERIFIED FAILED             

241 

 

EXCEEDED CONNECTION LIMIT                   

495 

8255 PORT CHIP CONTROL WORD CHECK FAILE      242 

 

NAM CCBE. PROG LOST                         

496 

NETWORK COMMUNICATION LINK FAIL PORT A      243 

 

MEMORY LOSS                                 

497 

NETWORK COMMUNICATION LINK FAIL PORT B       244 

 

DVC COMM LOSS                               

498 

STYLE 4 SHORT A L1                          

245 

 

A.C. POWER LOSS. BACK UP ACTIVATED          

499 

STYLE 4 SHORT B L1                          

246 

 

BUZZER OFF-LINE                             

500 

STYLE 4 SHORT A L2                          

247 

 

PANEL DOOR OPEN                             

501 

STYLE 4 SHORT B L2                          

248 

 

OFF NETWORK                                 

502 

STYLE 4 SHORT A L3                          

249 

 

INSTALL. ERROR                              

503 

STYLE 4 SHORT B L3                          

250 

 

OR AUDIO/TELEPHON                           

504 

STYLE 4 SHORT A L4                          

251 

 

EXPANDER MODULES                            

505 

STYLE 4 SHORT B L4                          

252 

 

MANUAL CONTROL                              

506 

STYLE 4 SHORT A L5                          

253 

 

CAT. COMM. FAULT                            

507 

STYLE 4 SHORT B L5                          

254 

 

UNKNOWN                                     

508 

Appendix C.3.

 

Error Messages 

Most error messages are associated with errors in parsing an incoming message from the Notifier panel.  The most 
likely cause is a mismatch in expected message format.  The driver will flag one of the following error messages 
and continue.  In most cases the message currently being processed by the driver will also be printed so that any 
problems can be easily diagnosed. 

Two screens ‘System Errors’ and ‘Driver Messages’ exist for displaying errors. 

The  System  Error  Screen  displays  the  error  number  and  the  Driver  messages  screen  displays  the  error  number, 
description and the message received from the NCA/NCA2 Panel. 

In debug mode the System Error screen will also include Driver messages.  

The following Error Messages appear upon the ‘System Errors’ Screen 

 

%d means numeric number 

 

%s means string 

 Messages  number  1,  3,  4  and  5  will  be  displayed  just  once  if  generated  after  rebooting  or  power  cycling  the 
FieldServer. 

Error 

Description 

Action 

#1 FYI. Incoming data is 
being  abandoned  on 
Port<%d> 

Node<%u> 

Loop<%d> 
Data_Type<%s> 
Address<%d> 

The  FieldServer  got  a  recognized 
message  on  this  particular  port,  Node, 
loop,  Address_Type  and  Address  but 
did not find a defined Map Descriptor. 

To  capture  this  data,  add  a  new  Map 
Descriptor with the required parameters. 

Содержание FS-8700-130

Страница 1: ...cument Revision 3 A Sierra Monitor Company APPLICABILITY EFFECTIVITY Effective for all systems manufactured after March 2010 Driver Manual Supplement to the FieldServer Instruction Manual FS 8700 130 Notifier NCA2 NFS2 3030 ...

Страница 2: ... Mapping 7 5 2 Client Side Connection Parameters 9 5 3 Client Side Node Parameters 9 5 4 Client Side Map Descriptor Parameters 10 5 4 1 FieldServer Related Map Descriptor Parameters 10 5 4 2 Driver Related Map Descriptor Parameters 10 5 4 3 Map Descriptor Example Standard example 11 6 Configuring the FieldServer as a Notifier NCA2 NFS2 3030 Server 12 Appendix A Useful Information 13 Appendix A 1 N...

Страница 3: ...itored by third party tools Since the FieldServer does not actively poll for data the accuracy and timeliness of the stored data is limited to the frequency of update messages that the Notifier Fire Panel issues If a networked panel does not send the CLEARED message for latched points via the NCA2 it is not possible to detect cleared points unless a system reset is done It is possible to configure...

Страница 4: ...n drawing Configure the Notifier Panel according to manufacturer s instructions FieldServer FieldServer Part 8917 16 Pigtail for RJ45 Port RJ45 Connection to TB5 Printer Port Notifier NCA2 NFS2 3030 Connect to one of the RS 232 Ports on the FieldServer P1 CTX CRX REF PTX PRX REF TB5 Printer CRT Rx Brown Tx Orange White Com Blue White 1 8 Connector Pinouts TB5 CRT Function Receive Reference Transmi...

Страница 5: ...l 408 262 2299 Fax 408 262 2269 Toll Free 888 509 1970 email support fieldserver com 3 1 Hardware Connection Tips Hints The FieldServer should preferably be connected to the TB5 Printer port It is theoretically possible to connect to the TB5 CRT port but this has not been fully tested The Panel s port must be enabled and set to 80 Columns Not Supervised ...

Страница 6: ...ion Title Data_Arrays Column Title Function Legal Values Data_Array_Name Provide name for Data Array Up to 15 alphanumeric characters Data_Array_Format Provide data format Each Data Array can only take on one format FLOAT BIT UInt16 SInt16 Byte Packed_Byte Swapped_Byte Data_Array_Length Number of Data Objects Must be larger than the data storage area required by the Map Descriptors for the data be...

Страница 7: ... the FieldServer This section documents and describes the parameters necessary for configuring the FieldServer to receive information from a Notifier Panel 5 1 Panel Status Memory Mapping The primary purpose of this driver is to record the status of devices connected to the Notifier panel by interpreting the text messages sent to the printer or CRT port Not all messages will be interpreted as many...

Страница 8: ...Active 1432 1590 ON OFF 1591 1749 Memory Type Detector_Trouble Module_Trouble Troubles Faults 1 159 Parameter Addresses For each Node Memory Type Node_Trouble Troubles Faults 1 508 Memory Type Panel Panel Maximum12 Boards and 8 Panel circuits per Board Hardware address memory address Board 1 panel 1 1 Board 1 panel 2 2 Board 2 panel 1 9 Board 12 panel 8 96 Fire Alarm 1 96 Security Life 97 192 Life...

Страница 9: ...ts Specify data bits 8 Vendor limitation Stop_Bits Specify stop bits 1 Vendor limitation Example Client Side Connections Connections Port Protocol Baud Stop_Bits Parity P8 nfs2 nca 9600 1 None 5 3 Client Side Node Parameters Section Title Nodes Column Title Function Legal Values Node_Name Provide name for Node Up to 32 alphanumeric characters Node_ID Station address of any physical Node on network...

Страница 10: ...iptor Parameters Column Title Function Legal Values Node_Name Name of Node to fetch data from One of the Node names specified in Section 5 3 Data_Type Specify memory area type Detector Module Detector_Trouble Module_Trouble Panel Panel_Trouble Bell_Trouble Node_Trouble Address Starting address of block As per Data_type Detector Module 1 1749 Detector_Trouble Module_Trouble 1 159 for point troubles...

Страница 11: ..._N2_Troubles DA_SYS_N2 0 Passive NODE2 Node_Trouble 1 508 SMD_N2_PANEL DA_N2_PANEL 0 Passive NODE2 Panel 1 1056 SMD_N2_PANEL_T DA_N2_PANEL_T 0 Passive NODE2 Panel_Trouble 1 96 SMD_N2_BELL_T DA_N2_BELL_T 0 Passive NODE2 Bell_Trouble 1 4 SMD_N2L01D DA_N2L01D 0 Passive NODE2 1 Detector 1 1749 SMD_N2L01D_T DA_N2L01D_T 0 Passive NODE2 1 Detector_Trouble 1 159 SMD_N2L01M DA_N2L01M 0 Passive NODE2 1 Modu...

Страница 12: ...logies 1991 Tarob Court Milpitas California 95035 USA Web www fieldserver com Tel 408 262 2299 Fax 408 262 2269 Toll Free 888 509 1970 email support fieldserver com 6 CONFIGURING THE FIELDSERVER AS A NOTIFIER NCA2 NFS2 3030 SERVER This driver cannot be configured as a Server ...

Страница 13: ...Appendix A 3 Driver Limitations and Exclusions Zone information will not be recorded To synchronize the FieldServer with the panel connect the running FieldServer and press the System Reset button on the panel All current events will be re sent to the FieldServer The port must be enabled on the unit and set to 80 columns with NO supervision All data related to non event driven reports will not be ...

Страница 14: ...ground potential problems Appendix B 2 Networking Tips By default FieldServer does not take any action on receiving a SYSTEM RESET Normally when a Node initiates SYSTEM RESET by pressing the RESET button on the Panel the panel sends an individual CLEAR message for every point it clears in its memory area The FieldServer therefore waits for the CLEAR message to clear a specific bit in its memory fo...

Страница 15: ...ates 1 0 SECURITY ALARM CLEARED SECURITY ALARM states 1 0 CRITICAL PROCESS CRITICAL PROCESS states 1 0 SUPERVISORY CLEARED SUPERVISORY states 1 0 TROUBLE FAULT CLEARED TROUBLE FAULT States counter DISABLED CLEARED DISABLED states 1 0 PREALARM CLEARED PREALARM states 1 0 ACTIVE CLEARED ACTIVE states 1 0 ON OFF OFF states 1 0 SYSTEM NORMAL Resets all addresses in all memory areas but only if data is...

Страница 16: ...D 5 276 STYLE 6 NEG LOOP 10 23 COMM FAULT LOOP INTERFACE BOARD 6 277 STYLE 6 POS LOOP 1 24 COMM FAULT LOOP INTERFACE BOARD 7 278 STYLE 6 POS LOOP 2 25 COMM FAULT LOOP INTERFACE BOARD 8 279 STYLE 6 POS LOOP 3 26 COMM FAULT LOOP INTERFACE BOARD 9 280 STYLE 6 POS LOOP 4 27 COMM FAULT LOOP INTERFACE BOARD 10 281 STYLE 6 POS LOOP 5 28 CATASTROPHIC ISIB COMMUNICATIONS FAULT 282 STYLE 6 POS LOOP 6 29 MEM...

Страница 17: ...BOVE LIMIT ON LOOP 10 335 REMOTE DISPLAY 2 TROUBLE 82 TOO MANY DEVICES ON LOOP 1 336 REMOTE DISPLAY 3 TROUBLE 83 TOO MANY DEVICES ON LOOP 2 337 REMOTE DISPLAY 4 TROUBLE 84 TOO MANY DEVICES ON LOOP 3 338 REMOTE DISPLAY 5 TROUBLE 85 TOO MANY DEVICES ON LOOP 4 339 REMOTE DISPLAY 6 TROUBLE 86 TOO MANY DEVICES ON LOOP 5 340 REMOTE DISPLAY 7 TROUBLE 87 TOO MANY DEVICES ON LOOP 6 341 REMOTE DISPLAY 8 TRO...

Страница 18: ...NNUN 6 NO ANSWER 138 LIB 8 NIB COMMUNICATION ERROR 392 ANNUN 7 NO ANSWER 139 LIB 9 COMMUNICATION ERROR 393 ANNUN 8 NO ANSWER 140 LIB 10 NIB COMMUNICATION ERROR 394 ANNUN 9 NO ANSWER 141 LIB 1 NIB M S PROGRAMMING ERROR 395 ANNUN 10 NO ANSWER 142 LIB 2 NIB M S PROGRAMMING ERROR 396 ANNUN 11 NO ANSWER 143 LIB 3 NIB M S PROGRAMMING ERROR 397 ANNUN 12 NO ANSWER 144 LIB 4 NIB M S PROGRAMMING ERROR 398 A...

Страница 19: ...R SECONDARY STATUS 450 UDACT NO ANSWER 197 LINK PROTECTOR PRIMARY NOT PRESENT 451 MASTER BOX NO ANSWER 198 EVENT BUFFER 80 FULL 452 DAA NO ANSWER 199 EBI STATUS 453 NO ANSWER 200 SOFTWARE MISMATCH 454 NETWORK FAILURE 201 NO POWER SUPPLY INST 455 WORKSTATION FAN FAILURE 202 TEST PROGRAM UPDATE 456 UPS FAILURE 203 HISTORY 80 FULL 457 NCM COMM FAILURE 204 FLASH IMAGE ERROR 458 NODE COMMUNICATIONS FAI...

Страница 20: ...R OPEN 501 STYLE 4 SHORT B L2 248 OFF NETWORK 502 STYLE 4 SHORT A L3 249 INSTALL ERROR 503 STYLE 4 SHORT B L3 250 OR AUDIO TELEPHON 504 STYLE 4 SHORT A L4 251 EXPANDER MODULES 505 STYLE 4 SHORT B L4 252 MANUAL CONTROL 506 STYLE 4 SHORT A L5 253 CAT COMM FAULT 507 STYLE 4 SHORT B L5 254 UNKNOWN 508 Appendix C 3 Error Messages Most error messages are associated with errors in parsing an incoming mes...

Страница 21: ... and you need this new trouble status contact FieldServer 5 Err Unknown OFF NETWORK Node s The FieldServer received a message that a Node either connected or disconnected from the network but no Node number was received it is likely that the message was corrupted Call Tech support 6 Err Unsupported Point Address Format s A message was received from an unsupported device or the address of the devic...

Отзывы: