FieldServer FS-8700-114 X30 Скачать руководство пользователя страница 11

FS-8700-114 DeviceNet Master Manual 

 

 

 

 

 

Page 11 of 15 

 

FieldServer Technologies

 1991 Tarob Court Milpitas, California 95035 USA   

Web

: www.fieldserver.com 

Tel

: (408) 262 2299   

Fax

: (408) 262 2269   

Toll Free

: (888) 509 1970   

email

[email protected] 

Appendix A.2. 

Using RSNetWorx  

Please refer to the following document on the HMS website, www.anybus.com  
ANYBUS-M  DEVICENET  MASTER/SCANNER  APPENDIX  Revision  1.02  -  Section  5.3 
“Configuration with RSNetworx”. 

Содержание FS-8700-114 X30

Страница 1: ...CABILITY EFFECTIVITY Effective for all systems manufactured after September 2008 Driver Manual Supplement to the FieldServer Instruction Manual FS 8700 114 X30 DeviceNet Master Adapter Driver Driver Version 1 01 Document Revision 3 ...

Страница 2: ...onnection Tips Hints 5 4 CONFIGURING THE FIELDSERVER AS A DEVICENET MASTER 6 4 1 DeviceNet Settings 6 4 2 Client Side Connection Descriptors 7 4 3 Client Side Node Descriptors 7 4 4 Client Side Map Descriptors 8 4 4 1 FieldServer Specific Map Descriptor Parameters 8 4 4 2 Driver Specific Map Descriptor Parameters 8 4 4 3 Map Descriptor Example 9 APPENDIX A ADVANCED TOPICS 10 Appendix A 1 DeviceNet...

Страница 3: ...ation on a DeviceNet network The FieldServer DeviceNet adapter is implemented as an ODVA profile 12 communications adapter Standard DeviceNet Baudrates of 125k 250k and 500kbit s are supported The DeviceNet Master Scanner can open IO connections of up to a total of 512 Bytes in each direction to DeviceNet Slaves Max Nodes Supported FieldServer Mode Nodes Comments Client 1 The FieldServer can only ...

Страница 4: ...Server Technologies for this driver FieldServer Technologies PART Description FS 8700 114 Driver Manual X30 DeviceNet Master Anybus M DeviceNet Card 2 2 Provided by the Supplier of 3rd Party Equipment 2 2 1 Required 3rd Party Software RSNetWorx RSLogix or another Network Scheduling Tool 2 2 2 Required 3rd Party Configuration Connection to a properly terminated DeviceNet network 2 2 3 Optional Item...

Страница 5: ...awing below Connector Pinouts Pin Signal Description Wire color 1 V Negative supply voltage black 2 CAN_L CAN_L Bus line blue 3 SHIELD Cable Shield bare 4 CAN_H CAN_H Bus line white 5 V Positive Supply Voltage red 3 1 Hardware Connection Tips Hints Use the recommended network cable and terminators as specified by the DeviceNet network organization and or the manufacturer of your network equipment ...

Страница 6: ...erfaces and the routing of data required In order to enable the FieldServer for DeviceNet communications the driver independent FieldServer buffers need to be declared in the Data Arrays section the FieldServer virtual node s needs to be declared in the Server Side Nodes section and the data to be provided to the clients needs to be mapped in the Server Side Map Descriptors section Details on how ...

Страница 7: ...eclared under Data Arrays section length of 8 Bit data array type recommended Example Server Side Connections Connections Adapter Protocol DNet_Master_Baudrate Command_DA_Name Status_DA_Name DNet X30_DNet_Master 500K Command_Reg Status_Reg 4 3 Client Side Node Descriptors Section Title Nodes Column Title Function Legal Values Node_Name Provide name for node Up to 32 alphanumeric characters Node_ID...

Страница 8: ... names from Data Array section above Data_Array_Offset Starting location in Data Array 0 to maximum specified in Data Array section above Function Function of Server Map Descriptor RDBC Reads data from the remote input buffer WRBC Writes data to the remote output buffer Scan_Interval Buffers Update Period 0 001s 4 4 2 Driver Specific Map Descriptor Parameters Column Title Function Legal Values Nod...

Страница 9: ...Name Data_Array_Name Data_Array_Offset Function Node_Name DeviceNet_Data_Type Address Length Scan_Interval Get_Data Input_Data 0 RDBC CN1 WORD 0 10 1s Put_Data Output_Data 0 WRBC CN1 WORD 0 10 1s Note that each address refers to an individual remote input and output buffer Each buffer can contain up to 512 bytes Read function map descriptor gets data from the DeviceNet network and stores it in the...

Страница 10: ...ency Description Off No power not initialized or no connections established Green On Online one or more connections established Green Flashing Online no connections established Red On Critical link failure Red Flashing Minor fault one or more connections have a minor fault LED 3 Module Status Color Frequency Description Off No power or not initialized Green On Module status is OK Red On Major faul...

Страница 11: ...35 USA Web www fieldserver com Tel 408 262 2299 Fax 408 262 2269 Toll Free 888 509 1970 email support fieldserver com Appendix A 2 Using RSNetWorx Please refer to the following document on the HMS website www anybus com ANYBUS M DEVICENET MASTER SCANNER APPENDIX Revision 1 02 Section 5 3 Configuration with RSNetworx ...

Страница 12: ...with DIP switches as depicted below Note The System_Station_Address parameter must be removed from the configuration file if the DIP switch setting is to be used If System_Station_Address has not been defined in the CSV file the DIP switch value for both MacID and Baudrate will be used and the baud parameter in the CSV file will be ignored Appendix B 2 Using the Command and Status Data Arrays The ...

Страница 13: ...erver side protocol of the FieldServer The following preload section can be placed in the configuration file to place the scanner in Run mode at power up Preloads Data_Array_Name Preload_Data_Format Preload_Data_Value Location Command_Reg Bit 1 0 Offset zero of the Status Data Array indicates the Scanner s actual mode achieved A non zero value indicates the Scanner is in Run mode and a value of ze...

Страница 14: ... Technologies 1991 Tarob Court Milpitas California 95035 USA Web www fieldserver com Tel 408 262 2299 Fax 408 262 2269 Toll Free 888 509 1970 email support fieldserver com Example If the Master reports a network failure the following screenshot will be displayed ...

Страница 15: ...put buffer the data is written from the FieldServer s Data Array by the WRBC function Map Descriptor Write Data Block Continuous into the DN Master card s internal output buffer from where it is transferred across the DeviceNet network to the external DN Slave s input buffer 0 1 243 0 1 243 Card output buffer Card input buffer External DN Slave 01 DeviceNet Network 0 1 243 0 1 243 Card output buff...

Отзывы: