FieldServer BACnet Скачать руководство пользователя страница 2

BACnet

®

 Protocol Converter Kit 

 

3015-5609 Rev 1

 

2.  Items Required 

  Medium Phillips head screwdriver 

  Medium flat head screwdriver 

  Small flat head screwdriver 

  FieldServer ProtoNode-RER Protocol Converter Kit (3015-5705) 

P/N 

Qty 

Description 

3015-5703 

FieldServer ProtoNode-RER Protocol Converter 

3015-5616 

Mounting Plate 

3015-5704 

Power Supply Cable Assembly 

3015-5617 

Ground Wire 

0002-2162 

Pan Head Screw (#6-32×5/16) with Washer 

0002-7757 

Pan Head Machine Screw (#8-32×1/2) 

0102-3673 

Hex Nut (#8-32) with Washer 

3015-5609 

FieldServer ProtoNode Installation Guide 

0104-4601 

Cable Tie Mount with Adhesive Base 

0104-4550 

Cable Ties (3/32” × 4” Long) 

 

 

 

WARNING:  

Failure to comply with these instructions may 

void the warranty. 

 

 

3.  Mounting the ProtoNode 

Bacharach recommends mounting the ProtoNode inside the MultiZone 

enclosure on the inside of the MZ door  (see figures  below) using the 

included hardware.  As an alternative, the ProtoNode may be mounted at 

an appropriate location near the MultiZone using the mounting holes on 

the ProtoNode enclosure. 

 

 

 

Содержание BACnet

Страница 1: ...tors Installation Manual 1 Scope The FieldServer ProtoNode is a BACnet protocol converter accessory for use with Bacharach s MultiZone family of gas monitors This manual explains the installation procedure and outlines the MODBUS registers that are supported by the ProtoNode configuration files Figure 1 FieldServer ProtoNode ...

Страница 2: ... with Washer 0002 7757 2 Pan Head Machine Screw 8 32 1 2 0102 3673 2 Hex Nut 8 32 with Washer 3015 5609 1 FieldServer ProtoNode Installation Guide 0104 4601 4 Cable Tie Mount with Adhesive Base 0104 4550 4 Cable Ties 3 32 4 Long WARNING Failure to comply with these instructions may void the warranty 3 Mounting the ProtoNode Bacharach recommends mounting the ProtoNode inside the MultiZone enclosure...

Страница 3: ...BACnet Protocol Converter Kit 3015 5609 Rev 1 3 Figure 2 Mounting Plate and Hex Nuts Figure 3 ProtoNode and Mounting Plate ...

Страница 4: ...BACnet Protocol Converter Kit 4 3015 5609 Rev 1 Figure 4 ProtoNode Secured onto Mounting Plate Back View Figure 5 ProtoNode Mounted Inside MZ Door ...

Страница 5: ...meant to replace the existing MZ cable It plugs into J3 of the main board and J5 of the power supply board see Figure 6 The 12V and ground wires of the new cable have been lengthened and are un terminated so that they can be inserted into the terminal block connector on the ProtoNode The kit also contains a green cable for grounding Connections are illustrated in the photo and chart below See Figu...

Страница 6: ...ecessary wiring and an appropriate power supply 5 RS 485 Network Wiring The RS 485 bus should be wired in accordance with the practices described in the MZ manual and FieldServer s ProtoNode documentation Connections are illustrated in the photo and chart below Network wiring is not supplied in this kit Figure 8 RS 485 Network Connections Pin No Silkscreen Connector Labels Pin 1 Tx B Pin 2 Rx A Pi...

Страница 7: ...ing to the refrigerant type setting should only occur when the MZ is being configured Frequent writes should be avoided BACnet Object ID BACnet Object Description Zone BACnet Object Type Access R Read W Write Source MODBUS Register Number MODBUS Register Description 1 Active Zone Analog Input R 0x0011 Status 2 Fault Analog Input R 3 PPM 1 Analog Input R 0x1201 Zone 1 Data 4 Refrig Type 1 Analog In...

Страница 8: ...PPM 6 Analog Input R 0x1206 Zone 6 Data 24 Refrig Type 6 Analog Input R 25 Refrig Type 6 Analog Value W 26 Alarm 6 Analog Input R 27 PPM 7 Analog Input R 0x1207 Zone 7 Data 28 Refrig Type 7 Analog Input R 29 Refrig Type 7 Analog Value W 30 Alarm 7 Analog Input R 31 PPM 8 Analog Input R 0x1208 Zone 8 Data 32 Refrig Type 8 Analog Input R 33 Refrig Type 8 Analog Value W 34 Alarm 8 Analog Input R 35 P...

Страница 9: ...Refrig Type 13 Analog Input R 53 Refrig Type 13 Analog Value W 54 Alarm 13 Analog Input R 55 PPM 14 Analog Input R 0x120E Zone 14 Data 56 Refrig Type 14 Analog Input R 57 Refrig Type 14 Analog Value W 58 Alarm 14 Analog Input R 59 PPM 15 Analog Input R 0x120F Zone 15 Data 60 Refrig Type 15 Analog Input R 61 Refrig Type 15 Analog Value W 62 Alarm 15 Analog Input R 63 PPM 16 Analog Input R 0x1210 Zo...

Страница 10: ...r to the FieldServer documentation You may also refer to the FieldServer website at www fieldserver com For additional information on Bacharach s MultiZone Gas Monitor refer to the MZ Instruction Manual P N 3015 5074 provided with your MZ You may also access the latest MZ instruction manual at the Bacharach website www MyBacharach com ...

Страница 11: ...BACnet Protocol Converter Kit 3015 5609 Rev 1 11 ...

Страница 12: ... FieldServer is a trademark of FieldServer Technologies a Sierra Monitor Company ProtoNode is a product of FieldServer Technologies Headquarters 621 Hunt Valley Circle New Kensington PA 15068 7074 Toll Free 1 800 736 4666 Tel 1 724 334 5000 Fax 1 724 334 5001 Website www MyBacharach com E mail help MyBacharach com Printed in U S A ...

Отзывы: