background image

11

16

12

17

13

18

14

19

15

20

Specifications

Sensing element:

  

Enhanced infrared photo optics

Sensor life: Up to 10 years

Refrigerants: R-744 Carbon Dioxide (CO2) 

Sensitivity Levels:

High:  

Up to 6 grams/yr (0.2oz/yr)

Medium: 

Up to 14 grams/yr (0.5oz/yr)

Low:   

Up to 28 grams/yr (1oz/yr)

Response time: 1 second

Recovery time: ~4 seconds

Auto off: 10 minutes after no activity

Battery: 3.7VDC(nominal), rechargeable lithium 

ion user-replaceable battery.

Battery life: 8 hours continuous use prior to  

needing a charge. Degradation (30%) after 

500 charge/discharge cycles or two years, 

whichever comes first.

Low battery LED:  Lights when approximately 1 

hour of battery life remains.

Charge time: Less than 4 hours (either charger)

Operating environment: 32ºF (0°C) to 104ºF (40°C) 

at <75%RH (non-condensing)

Storage environment: <80%RH meter and batt.

For 80% battery recovery:

-4ºF (-20°C) to 140ºF (60°C) less than 1 month

-4ºF (-20°C) to 113ºF (45°C) less than 3 months

-4ºF (-20°C) to 68ºF (20°C) less than 1 year

Included Accessories

Use model RRE2 when detecting in tight 

spaces, such as through a condenser grille. 

Model RFE2 extends the wand to 25.5” (65cm). 

The blow molded case, model holds accessories 

and chargers.

All accessories shown are included with the 

SCL2.

Lithium Battery Care

The SCL2 contains a very powerful lithium 

ion battery.  For a long battery life and safe 

operation, you must observe the following:

Cautions

1  Do not expose the battery to temperatures 

higher than 140ºF (60°C). 

2  Do not charge the battery in or nearby heated 

places, such as fire, hot vehicles, or direct 

sunlight. 

3  Do not solder directly onto the battery.

4  Do not expose the battery to direct impact or 

throw it.   

5  Do not get the battery wet.

6  Do not deform or pierce the battery in any way.  

7  If there is any battery leakage, do not touch 

the battery. In the case that electrolyte gets 

into the eyes, flush with fresh water, do not 

rub, and see a physician immediately. 

8  Replace immediately if there is any deformity, 

bad smell, color change, or other abnormality.

9  The battery is user-replaceable and can be 

purchased at most electronic stores. The fol-

lowing batteries are known to be compatible 

with the SCL2: Fuji Film:NP-120, PENTAX: DLI-7, 

RICON: DB-43

Charging

Two chargers are included with the SCL2. 

The AC charger plugs into a wall outlet and the 

car charger plugs into a car cigarette lighter DC 

plug.

1  The battery is partially charged when pack-

aged. Fully charge the battery before first use. 

2  The LOW-BATT LED will light red when the 

battery is low. 

3  To recharge the SCL2, plug one end of the 

charger into the top of the SCL2 and the 

other into the power source. LOW-BATT 

will blink while charging until the battery is 

fully charged.  When the SCL2 battery is fully 

charged, LOW-BATT turns off. 

4  Charge within operating environment speci-

fied in the Specifications section on page 11. 

5  Avoid frequent full discharges. Several partial 

discharges with frequent recharges are better 

for lithium-ion batteries. Unlike nickel-based 

batteries they have no charge memory, and 

do not need to be discharged before charging.

Storage 

The battery should have a 40%-50% charge 

during prolonged storage of a month or longer. 

See Specifications section in this manual for 

proper storage environment. 

Battery life is dramatically reduced if the 

battery is stored fully charged and/or at high 

temperatures.

Maintenance

Clean the exterior with a dry cloth.  Do not 

use liquid.

Filter Assessment & Replacement

The filter blocks moisture and other 

contaminants from the sensor. When it gets 

wet, it constricts flow of air and will have to be 

replaced. Unscrew the sensor tip and replace 

the white filter so that the rounded end is 

closest to the tip of the wand. Use only the 

Fieldpiece supplied filter. 

You can order extra bags of replacement 

parts (Part# RFL2) from your local distributor. 

Limited Warranty

This meter is warranted against defects 

in material or workmanship for one year 

from date of purchase from an authorized 

Fieldpiece dealer. Fieldpiece will replace or 

repair the defective unit, at its option, subject 

to verification of the defect.

This warranty does not apply to defects 

resulting from abuse, neglect, accident, 

unauthorized repair, alteration, or unreasonable 

use of the instrument.

Any implied warranties arising from the sale of 

a Fieldpiece product, including but not limited 

to implied warranties of merchantability and 

fitness for a particular purpose, are limited to 

the above. Fieldpiece shall not be liable for loss 

of use of the instrument or other incidental or 

consequential damages, expenses, or economic 

loss, or for any claim of such damage, expenses, 

or economic loss. 

State laws vary. The above limitations or 

exclusions may not apply to you.

Obtaining Service

Email Fieldpiece warranty department at 

[email protected] for current fixed 

price repair service. Send check or money 

order made out to Fieldpiece Instruments for 

the amount quoted. If your meter is under 

warranty there will be no cost for the repair/

replacement. Send your meter, freight prepaid, 

to Fieldpiece Instruments. Send proof of date 

and location of purchase for in-warranty service. 

The meter will be repaired or replaced, at the 

option of Fieldpiece, and returned via least cost 

transportation.

For international customers, warranty for 

products purchased outside of the U.S. should 

be handled through local distributors. Visit our 

website to find your local distributor.

More from Fieldpiece

Model SMAN460

Wireless 4-Port Manifold 

with Micron Gauge

Model SDP2

Dual In-duct Psychrometer

Model RRE2

9" (23cm) Needle tip probe

Model RFE2

9" (23cm) Flex extension

Model ADMK3

Blow molded case

Model RCA2

Car Charger

Model RWA2

Wall Charger

Model RFL2

Replacement filters (10) 

and O-rings (5)

80

80

Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176

 TestEquipmentDepot.com 