11
16
12
17
13
18
14
19
15
20
Specifications
Sensing element:
Enhanced infrared photo optics
Sensor life: Up to 10 years
Refrigerants: R-744 Carbon Dioxide (CO2)
Sensitivity Levels:
High:
Up to 6 grams/yr (0.2oz/yr)
Medium:
Up to 14 grams/yr (0.5oz/yr)
Low:
Up to 28 grams/yr (1oz/yr)
Response time: 1 second
Recovery time: ~4 seconds
Auto off: 10 minutes after no activity
Battery: 3.7VDC(nominal), rechargeable lithium
ion user-replaceable battery.
Battery life: 8 hours continuous use prior to
needing a charge. Degradation (30%) after
500 charge/discharge cycles or two years,
whichever comes first.
Low battery LED: Lights when approximately 1
hour of battery life remains.
Charge time: Less than 4 hours (either charger)
Operating environment: 32ºF (0°C) to 104ºF (40°C)
at <75%RH (non-condensing)
Storage environment: <80%RH meter and batt.
For 80% battery recovery:
-4ºF (-20°C) to 140ºF (60°C) less than 1 month
-4ºF (-20°C) to 113ºF (45°C) less than 3 months
-4ºF (-20°C) to 68ºF (20°C) less than 1 year
Included Accessories
Use model RRE2 when detecting in tight
spaces, such as through a condenser grille.
Model RFE2 extends the wand to 25.5” (65cm).
The blow molded case, model holds accessories
and chargers.
All accessories shown are included with the
SCL2.
Lithium Battery Care
The SCL2 contains a very powerful lithium
ion battery. For a long battery life and safe
operation, you must observe the following:
Cautions
1 Do not expose the battery to temperatures
higher than 140ºF (60°C).
2 Do not charge the battery in or nearby heated
places, such as fire, hot vehicles, or direct
sunlight.
3 Do not solder directly onto the battery.
4 Do not expose the battery to direct impact or
throw it.
5 Do not get the battery wet.
6 Do not deform or pierce the battery in any way.
7 If there is any battery leakage, do not touch
the battery. In the case that electrolyte gets
into the eyes, flush with fresh water, do not
rub, and see a physician immediately.
8 Replace immediately if there is any deformity,
bad smell, color change, or other abnormality.
9 The battery is user-replaceable and can be
purchased at most electronic stores. The fol-
lowing batteries are known to be compatible
with the SCL2: Fuji Film:NP-120, PENTAX: DLI-7,
RICON: DB-43
Charging
Two chargers are included with the SCL2.
The AC charger plugs into a wall outlet and the
car charger plugs into a car cigarette lighter DC
plug.
1 The battery is partially charged when pack-
aged. Fully charge the battery before first use.
2 The LOW-BATT LED will light red when the
battery is low.
3 To recharge the SCL2, plug one end of the
charger into the top of the SCL2 and the
other into the power source. LOW-BATT
will blink while charging until the battery is
fully charged. When the SCL2 battery is fully
charged, LOW-BATT turns off.
4 Charge within operating environment speci-
fied in the Specifications section on page 11.
5 Avoid frequent full discharges. Several partial
discharges with frequent recharges are better
for lithium-ion batteries. Unlike nickel-based
batteries they have no charge memory, and
do not need to be discharged before charging.
Storage
The battery should have a 40%-50% charge
during prolonged storage of a month or longer.
See Specifications section in this manual for
proper storage environment.
Battery life is dramatically reduced if the
battery is stored fully charged and/or at high
temperatures.
Maintenance
Clean the exterior with a dry cloth. Do not
use liquid.
Filter Assessment & Replacement
The filter blocks moisture and other
contaminants from the sensor. When it gets
wet, it constricts flow of air and will have to be
replaced. Unscrew the sensor tip and replace
the white filter so that the rounded end is
closest to the tip of the wand. Use only the
Fieldpiece supplied filter.
You can order extra bags of replacement
parts (Part# RFL2) from your local distributor.
Limited Warranty
This meter is warranted against defects
in material or workmanship for one year
from date of purchase from an authorized
Fieldpiece dealer. Fieldpiece will replace or
repair the defective unit, at its option, subject
to verification of the defect.
This warranty does not apply to defects
resulting from abuse, neglect, accident,
unauthorized repair, alteration, or unreasonable
use of the instrument.
Any implied warranties arising from the sale of
a Fieldpiece product, including but not limited
to implied warranties of merchantability and
fitness for a particular purpose, are limited to
the above. Fieldpiece shall not be liable for loss
of use of the instrument or other incidental or
consequential damages, expenses, or economic
loss, or for any claim of such damage, expenses,
or economic loss.
State laws vary. The above limitations or
exclusions may not apply to you.
Obtaining Service
Email Fieldpiece warranty department at
[email protected] for current fixed
price repair service. Send check or money
order made out to Fieldpiece Instruments for
the amount quoted. If your meter is under
warranty there will be no cost for the repair/
replacement. Send your meter, freight prepaid,
to Fieldpiece Instruments. Send proof of date
and location of purchase for in-warranty service.
The meter will be repaired or replaced, at the
option of Fieldpiece, and returned via least cost
transportation.
For international customers, warranty for
products purchased outside of the U.S. should
be handled through local distributors. Visit our
website to find your local distributor.
More from Fieldpiece
Model SMAN460
Wireless 4-Port Manifold
with Micron Gauge
Model SDP2
Dual In-duct Psychrometer
Model RRE2
9" (23cm) Needle tip probe
Model RFE2
9" (23cm) Flex extension
Model ADMK3
Blow molded case
Model RCA2
Car Charger
Model RWA2
Wall Charger
Model RFL2
Replacement filters (10)
and O-rings (5)
80
80
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176