background image

EN

6

FDAH 200

2

General safety instructions 

FDK 2001-E

10

EN

General safety instructions

2.GENERAL SAFETY RULES

WARNING:

 Read and understand all instructions. Failure to follow all instructions 

listed below may result in serious injury.

WARNING:  The  warnings,  cautions,  and  instructions  discussed  in  this  instruction 

manual cannot cover all possible conditions or situations that could occur.

 It must 

be  understood  by  the  operator  that  common  sense  and  caution  are  factors  that 

cannot be built into this product, but must be supplied by the operator.

CAUTION: 

Do not allow persons to operate or assemble this jack until they 

have read this manual and have developed a thorough understanding of 

how the jack works.

 

DO NOT

  

OPERA

 

TE

 

OR

 

REP

 

AIR

 

THIS

 

EQUIPMENT WITHOUT READING THIS MANUAL.

To maintain the Service Jack and user safety, the responsibility of the owner is 
to read and follow these instructions.

Inspect the service jack for proper operation and function.
Keep instructions readily available for equipment operators.

Make certain all equipment operators are properly trained; understand how to 

safely and correctly operate the unit.
Allow unit operation only with all parts in place and operating properly.

Use only genuine replacement parts.

Service and maintain the unit only with authorized or approved replacement 

parts; negligence will make the jack unsafe for use and void the warranty.
Carefully inspect the unit on a regular basis and perform all maintenance as required.
Store these instructions in the handle of your jack.

Keep all decals on the unit clean and visible.

For purpose of car lifting only, max. 2t

Can be used on straight and strong surface less than 3 degrees 

angle Ano

 

the

 

r pur

 

op

 

ose of

 

 usage is st

   

rictly

 

 pro

 

hi

 

bit

 

ed

 

 

 

 

DO NOT LIE DOWN UNDER THE LIFT

 

 

E

 

D CAR!

 

!! ALWAYS USE

 

 

 

THE SUPPORT!!!

 

Before 

 

using

     

 this product, read the

   

 

 

owner's manual completely and familiarize 

yourself

 

 

 

 

thoroughly with the product and the hazards associated 

 

 

with its improper use. 

 

Perform 

   

the air purge 

 

procedure. 

 

 

(

 

See System Purge

 

 

 

Procedure.)

  

Check and that the pump operates smoothly before putting into service.

 

 

Inspect before each 

 

 

 

use

 

. Do

 

 

 

not 

 

use if bent

 

 

broken or cracked components are    

noted.

Содержание FDAH 2002

Страница 1: ...FDAH 2002...

Страница 2: ...ser s manual and save it for possible future use CONTENTS 3 E G NERAL SAFETY REGULATIONS ILLUSTRATED ATTACHMENT 4 GENERAL SAFETY RULES 6 ASSEMBLY 11 TO ADD JACK OIL 17 TROUBLE SHOOTING 19 TECHNIAL SPE...

Страница 3: ...ctions for use Familiarize with operating elements and the proper use of the device Keep the manual in a safe place for future reference We recommend keeping the original package including the inner p...

Страница 4: ...eave your power tool unattended Keep the equipment away from animals Service Do not replace parts of the power tool do not make any repairs or interfere in any way with the construction of the power t...

Страница 5: ...ilable for equipment operators Make certain all equipment operators are properly trained understand how to safely and correctly operate the unit Allow unit operation only with all parts in place and o...

Страница 6: ...3O Always follow safety precautions when installing and operating this jack Keep all decals on the unit clean and visible Before proceeding ensure that you fully understand and comprehend the full con...

Страница 7: ...lock s or stabilizer s should have a weight capacity that is greater than the weight of the load which is being lifted Do not move or dolly the vehicle while on the jack Lift only on areas of the vehi...

Страница 8: ...supported only by the jack Do not allow anyone in the vehicle while the jack is in use Keep all bystanders away from vehicle when in use Inspection Inspect the jack carefully before each use Ensure t...

Страница 9: ...10 OPERATING INSTRUCTIONS ELECTRICAL ANGLE GRINDER EN Symbols 3 SYMBOLS The product complies with the applicable standards and regulations To add jack oil...

Страница 10: ...n Manual attentively prior to use The product complies with the applicable standards and regulations Thread of jig 1 Familiarize yourself with the jack 2 Line up the bottom of handle to the release va...

Страница 11: ...eck for proper pump action Screwdriver Cover Plate IMPORTANT BEFORE FIRST USE Perform the following Air Purge Procedure to remove any air that may have been introduced into the hydraulic system as a r...

Страница 12: ...ifting stability Secure the load to prevent inadvertent shifting and movement Position the jack near desired lift point Set the Parking Brake in the vehicle Refer to the vehicle manufacturer owner s m...

Страница 13: ...K 7 Before raising the vehicle double check and verify the saddle is centered and also has full contact with the lifting point 8 Pump handle to lift until saddle contacts load Continue to pump the jac...

Страница 14: ...to the ground After un binding clean lubricate and test that equipment is working properly Rusty components dirt or worn parts can be causes of binding Clean and lubricate the equipment as indicated i...

Страница 15: ...ause corrosion and or rust This equipment will not operate safely without proper lubrication Using the equipment without proper lubrication will result in poor performance and damage to the equipment...

Страница 16: ...valve by turning handle counter clockwise 1 Position the jack on level ground and lower the saddle Remove the oil plug 3 Remove cover plate 2 4 Fill the oil case until oil level is just beneath the l...

Страница 17: ...S ADDITIONAL LUBRICATION Periodically check the pump piston and ram for signs of rust or corrosion As needed thoroughly wipe with a clean non scratching oil soluble cloth NEVER USE SANDPAPER OR ABRASI...

Страница 18: ...e moving parts Jack is binding or foreign obstruction Power unit malfunctioning Replace the power unit X X X X X X X X X X X X X X X Safe Operating Temperature is between 40 F 105 F 4 C 41 C 7 TECHNIC...

Страница 19: ...esourcesandyouhelppreventanypotential adverse effects on the environment and human health which could be the results of wrong waste disposal Ask your local authority or the nearest collection point fo...

Страница 20: ...111 100 00 Prague 10 Czech Republic Tax ID number CZ26726548 Product brand HYDRAULIC FLOOR JACK 2t FIELDMANN Type model FDAH 2002 This product meets the requirement of the directives and regulations b...

Отзывы: