page 2
WARNING:
Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness.
Never operate the UV-Aire Air Purifying System out of the plenum
. Avoid touching the glass portion of the lamp with your hands.
INSTALLATION
Determine a suitable location on either the supply or
1.
return for the unit as shown in Figure 1. The unit must be
mounted at least 3 feet from any flex duct type material.
NOTE:
Unit can only be mounted in a vertical position as
noted on inside cover label.
Apply mounting template to air duct. (See Figure 2)
2.
Drill
3.
1
⁄
8
" diameter mounting holes at positions indicated on
template. (See Figure 2)
Using a 2" hole saw, drill out lamp hole as shown on
4.
template. (See Figure 2)
Drill a
5.
7
⁄
8
" inspection hole as shown on template.
(See Figure 2)
Remove template.
6.
Mount unit to duct using the 4 supplied sheet metal screws.
7.
(See Figure 3)
Lamp Length
Minimum
Duct
Width
Volts
Amps
Hz Watts
Max Air
Temp ºF
Lamp Intensity at
1 meter
Recommended
Max Sq. Feet
12"
9
120/240
.5
60
30
150º
37µW/cm
2
1500
18"
14
120/240
.5
60
30
150º
73µW/cm
2
2000
28"
22
120/240
1.1
60
60
150º
105µW/cm
2
3000
Figure 1
Figure 3
Figure 2
GENERAL INFORMATION
This product is not sold as a medical device and is not for the purpose of diagnosis of any disease or
condition, nor for use in the mitigation, treatment, or prevention of any disease or condition.
There are different size units available, depending on the square footage of your home. See chart below for
determining your home’s needs.
WARNING:
Before installing or servicing a humidifier, air filter, heat system, or this unit, etc., always
turn all power OFF and have units unplugged. Electrical shock can cause personal injury or death.
Never expose eyes or skin to direct UVC light from any source.