This device 

MUST

 be installed by a qualified agency in accordance with the manufacturer's installation instructions. The definition of 

a qualified agency is: any individual, firm, corporation or company which either in person or through a representative is engaged 

in, and is responsible for, the installation and operation of HVAC appliances, who is experienced in such work, familiar with all the 

precautions required, and has complied with all the requirements of the authority having jurisdiction.

This product is not sold as a medical device and is not for the purpose of diagnosis of any disease or condition nor for 

use in the mitigation, treatment, or prevention of any disease or condition.

READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

Installation Date:

Installed By:

Phone:

WARNING:

  Never expose eyes or skin to UVC light from any source.

• Looking directly at the UVC light may cause permanent eye damage or blindness. 

• Never operate the UV-Aire Air Purifying System out of the plenum.

WARNING:

 UV light will break down plastic materials not rated for UV exposure:

(Examples: wire insulation, flex duct, drain pans, and humidifiers)

• The unit must be mounted at least 30” from the above stated type of materials.

• If it is necessary to mount the unit in direct line of sight of these types of materials, they must be    

   shielded with aluminum foil, aluminum foil tape, or sheet metal.

UV-AIRE

®

 AIR PURIFYING SYSTEM 

Model: UV-E

(For use with 12”, 18”, and 28” Field Controls Lamps)

(120/240 volt application)

ITEMS INCLUDED IN KIT:

1- UV-E power unit (NEMA3 housing)

1- Mounting Template

4- Sheet metal mounting screws

1- Angled mounting bracket

1- Flat mounting bracket

1- Instruction Sheet

1- Wing nut

2- Hex nuts

1- Lamp

READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION

LEAVE THE INSTALLATION INSTRUCTIONS WITH THE OWNER/OPERATOR OF THE DEVICE
AFTER OPENING THE CARTON, UNPACK AND INSPECT THE UNIT AND LAMP FOR DAMAGE.

DO NOT

 INSTALL THIS UNIT IF ANY DAMAGE IS NOTICEABLE.

SAFETY CONSIDERATIONS

UV-C light inhibits the growth and reproduction of 

germs and bacteria that circulate through a home’s 

heating and air conditioning system. The treatment 

is a safe, silent, and proven way to make your 

home a healthier place to live.

Содержание UV-AIRE UV-E

Страница 1: ...fying System out of the plenum WARNING UV light will break down plastic materials not rated for UV exposure Examples wire insulation flex duct drain pans and humidifiers The unit must be mounted at least 30 from the above stated type of materials If it is necessary to mount the unit in direct line of sight of these types of materials they must be shielded with aluminum foil aluminum foil tape or s...

Страница 2: ...on template See Figure 2 Remove template 6 Mount unit to duct using the 4 supplied sheet metal screws 7 See Figure 3 Lamp Length Minimum Duct Width Volts Amps Hz Watts Max Air Temp ºF Lamp Intensity at 1 meter Recommended Max Sq Feet 12 9 120 240 5 60 30 150º 37µW cm2 1500 18 14 120 240 5 60 30 150º 73µW cm2 2000 28 22 120 240 1 1 60 60 150º 105µW cm2 3000 Figure 1 Figure 3 Figure 2 GENERAL INFORM...

Страница 3: ...etermine length of wire and conduit 9 necessary according to power connection and install wiring conduit and water tight connector as shown in example figure 4 Supplied by installer Remove wiring access cover to expose 10 terminal block Figure 5 Push power source wires through bushing in access 11 cover then begin securing wires according to the wiring diagram in figure 8 See Figures 6 7 Replace a...

Страница 4: ...g Bracket Specifications Remove the two hex nuts and angled bracket from included bagged 1 hardware Install the angled bracket and secure to the unit base with the hex nuts 2 provided See Figure 11 The angle bracket may be mounted in 4 positions allowing the bulb to either be angled up and down or left to right depending upon duct design Figures A D NOTE Be sure to note location of lamp hole in br...

Страница 5: ...d 21 that the ballast is plugged in securely to lamp If lamp still does not glow contact technical support at 1 252 522 3031 for further assistance After unit has been found to be working properly note date of 22 installation on inside cover close cover and engage latch Apply supplied wire tie to latch or other locking mechanism to provide safety Figure 13 Figure 14 BULB MOUNTING BRACKET SELECTION...

Страница 6: ... IMPORTANT Turn switch on unit to OFF position and disconnect from power source Remove wire tie or locking mechanism from latch on unit 1 Unplug ballast plug from end of lamp 2 Remove the wing nut on securing bracket Swing out securing bracket to clear lamp 3 Slide lamp out carefully 4 NOTE When replacing the lamp always wipe off lamp before installing Replace lamp following the appropriate proced...

Страница 7: ...eld Controls Part Number 12 46365401 46365506 18 46365402 46365506 28 46365403 46365506 REPLACEMENT PARTS LIST For replacement parts contact your local heating service company Any questions please contact Field Controls at Phone 252 522 3031 Fax 252 522 0214 Email sales fieldcontrols com FLEX DUCT INSTALLATION For installations on duct systems with a metallic main duct and flex duct branches follo...

Страница 8: ...roof of purchase sales receipt identifying the Product purchased Product model or accurate date code information and the date the Product s was purchased 3 Product whose warranty quality stickers Product serial number plates or electronic serial numbers have been removed altered or rendered illegible shall not be covered under the limited warranty 4 Defective Product must be returned to Company po...

Отзывы: