WARNING:

 

Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness.

Never operate the UV-Aire

 Air Purifying System out of the plenum

. Avoid touching the glass portion of the lamp with your hands.

1

 Richard Riley, M.D. “Airborne Infection: The American Journal of Medicine, September 1974, Vol. 57 - 5/16/01

2

 The health aspects associated with the use of these products and their ability to aid in disinfecting of environmental air have not 

been investigated by UL.

LAMP Replacement Part Number

46511200

TROUBLESHOOTING GUIDE

Do not wire the unit into the appliance 24 volt fan or thermostat circuit. This will cause premature ballast 

1. 

or lamp failure and void the warranty. For proper operation, the unit requires 24VAC at all times.
Check to make sure 24VAC power is available at the transformer.

2. 

If lamp does not light up, pull back metal washer on mounting base. If lamp comes on, the base needs 

3. 

tightening to ensure that the safety switch is fully engaged.
If lamp does not light up, rotate ballast slightly clockwise or counter-clockwise.

4. 

If lamp does not light up after rotating ballast, replace lamp.

5. 

If unit still does not light up after replacing lamp, replace unit.

6. 

REPLACEMENT PARTS LIST

For replacement parts, contact Field Controls at:

Phone: 252-522-3031 • Fax: 252-522-0214

Email: [email protected]

CLEAN-UP OF BROKEN LAMPS

 (see warnings on page two of this manual)

UV lamps contain a small amount of mercury, like a typical fluorescent lamp. DO NOT touch any of the 

mercury with your bare hands.

While wearing disposable, non-absorbent protective gloves, carefully pick up the large pieces of glass 

1. 

with your hands.
Vacuum the entire area with a standard household vacuum cleaner ensuring the removal of all  

2. 

lamp material.
Dispose of the pieces of glass, the vacuum cleaner bag, and the disposable gloves in a sealed  

3. 

garbage bag.
Check with your local waste management authority for local disposal or recycling requirements. 

4. 

According to the EPA's Universal Waste Rule, these types of lamps may be disposed of into  

household waste.
Wash hands, and remove and wash clothes for added safety measures.

5. 

Содержание UV-16/24

Страница 1: ...hone UV AIRE AIR PURIFYING SYSTEM Model UV 16 24 The UV Aire unit is designed to emit powerful UVC Band light rays which sterilize and reduce airborne microorganisms as they pass through a heating or air conditioning system It is installed in the main supply or return duct and operates continuously to automatically purify the air in the home 24 hours a day This product is not sold as a medical dev...

Страница 2: ...In case of accidental exposure to internal contents of lamp wash hands and any other affected skin area with mild detergent Remove affected clothing immediately If skin surface is pierced seek medical attention immediately NOTE If you touch the glass of the lamp you should wipe the glass clean with isopropyl alcohol and a lint free wipe If the lamp is not cleaned the film of hand oils causes a red...

Страница 3: ...a vertical or horizontal position See Figure 2 Leave template mounted to duct for future reference Drill 3 1 8 diameter mounting holes at positions indicated on template See Figure 3 Cut out the large opening 1 4 1 2 hole on the template See Figure 3 Using a 5 1 4 to 1 2 drill bit drill a viewport hole as indicated on the template Figure 3 Optional Light Shield The light shield may be mounted 6 at...

Страница 4: ...e mounting base With the ballast pressed against the mounting base 11 rotate the ballast clockwise 90 Do not wire the unit into the appliance s 24 volt fan or thermostat circuit Premature failure of the ballast 12 and lamp will occur The warranty will be voided Do not wire into a standard 120VAC electric supply Wire according to Diagram A or Diagram B Unit is designed to be wired to a 24V 40VA pow...

Страница 5: ...ormer before commencing inspection and cleaning NOTE Wear disposable non absorbent protective gloves prior to inspection procedure in case of accidental breakage of glass We recommend inspecting and cleaning the lamp at least every 6 months Frequency depends upon the 1 environment Such as the type of air filter duration of use and replacement cycle To maintain maximum output intensity replace the ...

Страница 6: ...nst the mounting base Rotate the ballast assembly 8 clockwise until it stops and is locked in place See Figure 10 After assembly is firmly in place reconnect power to transformer and plug 9 the power supply cord back into the standard electrical outlet Check lamp operation by looking through the viewport hole A blue glow should be seen in the duct After replacing the lamp make sure to install the ...

Страница 7: ... that the safety switch is fully engaged If lamp does not light up rotate ballast slightly clockwise or counter clockwise 4 If lamp does not light up after rotating ballast replace lamp 5 If unit still does not light up after replacing lamp replace unit 6 REPLACEMENT PARTS LIST For replacement parts contact Field Controls at Phone 252 522 3031 Fax 252 522 0214 Email sales fieldcontrols com CLEAN U...

Страница 8: ...roof of purchase sales receipt identifying the Product purchased Product model or accurate date code information and the date the Product s was purchased 3 Product whose warranty quality stickers Product serial number plates or electronic serial numbers have been removed altered or rendered illegible shall not be covered under the limited warranty 4 Defective Product must be returned to Company po...

Отзывы: