www.fieldcontrols.com

Please retain these instructions after installation.

This device 

MUST

 be installed by a qualified agency in accordance with the manufacturer's installation instructions. The definition of 

a qualified agency is: any individual, firm, corporation or company which either in person or through a representative is engaged 

in, and is responsible for, the installation and operation of HVAC appliances, who is experienced in such work, familiar with all the 

precautions required, and has complied with all the requirements of the authority having jurisdiction.

This product is not sold as a medical device and is not for the purpose of diagnosis of any disease or condition nor for 

use in the mitigation, treatment, or prevention of any disease or condition.

READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

Installation Date:

Installed By:

Phone:

UV-AIRE AIR PURIFYING SYSTEM

Model: UV-16/24

The UV-Aire unit is designed to emit powerful UVC Band light rays, which sterilize and reduce airborne 

microorganisms as they pass through a heating or air conditioning system.  It is installed in the main supply 

or return duct and operates continuously to automatically purify the air in the home 24 hours a day.

This product is not sold as a medical device and is not for the purpose of diagnosis of any disease or 

condition, nor for use in the mitigation, treatment, or prevention of any disease or condition.

READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY 

BEFORE PROCEEDING WITH THE INSTALLATION.

WARNING:

 For use with 24V ONLY! Do not exceed voltage rating. Severe damage to device and/or 

fire could result.  Verify proper voltage. 

NOTE:

 This unit may require a supplemental 24V/40VA Transformer.

ITEMS INCLUDED IN KIT:

1-24Volt UV-Aire Ballast Assembly

1-Mounting Base

1-Ultraviolet Lamp

6-Sheet Metal Mounting Screws

1-Instruction Sheet

1-Fiberglass Duct Board 

   Mounting Bracket

1-UVC Light Shield

1-24V Transformer 

2-Fork Terminals

2-Wire Nuts

Содержание UV-16/24

Страница 1: ...hone UV AIRE AIR PURIFYING SYSTEM Model UV 16 24 The UV Aire unit is designed to emit powerful UVC Band light rays which sterilize and reduce airborne microorganisms as they pass through a heating or air conditioning system It is installed in the main supply or return duct and operates continuously to automatically purify the air in the home 24 hours a day This product is not sold as a medical dev...

Страница 2: ...In case of accidental exposure to internal contents of lamp wash hands and any other affected skin area with mild detergent Remove affected clothing immediately If skin surface is pierced seek medical attention immediately NOTE If you touch the glass of the lamp you should wipe the glass clean with isopropyl alcohol and a lint free wipe If the lamp is not cleaned the film of hand oils causes a red...

Страница 3: ...a vertical or horizontal position See Figure 2 Leave template mounted to duct for future reference Drill 3 1 8 diameter mounting holes at positions indicated on template See Figure 3 Cut out the large opening 1 4 1 2 hole on the template See Figure 3 Using a 5 1 4 to 1 2 drill bit drill a viewport hole as indicated on the template Figure 3 Optional Light Shield The light shield may be mounted 6 at...

Страница 4: ...e mounting base With the ballast pressed against the mounting base 11 rotate the ballast clockwise 90 Do not wire the unit into the appliance s 24 volt fan or thermostat circuit Premature failure of the ballast 12 and lamp will occur The warranty will be voided Do not wire into a standard 120VAC electric supply Wire according to Diagram A or Diagram B Unit is designed to be wired to a 24V 40VA pow...

Страница 5: ...ormer before commencing inspection and cleaning NOTE Wear disposable non absorbent protective gloves prior to inspection procedure in case of accidental breakage of glass We recommend inspecting and cleaning the lamp at least every 6 months Frequency depends upon the 1 environment Such as the type of air filter duration of use and replacement cycle To maintain maximum output intensity replace the ...

Страница 6: ...nst the mounting base Rotate the ballast assembly 8 clockwise until it stops and is locked in place See Figure 10 After assembly is firmly in place reconnect power to transformer and plug 9 the power supply cord back into the standard electrical outlet Check lamp operation by looking through the viewport hole A blue glow should be seen in the duct After replacing the lamp make sure to install the ...

Страница 7: ... that the safety switch is fully engaged If lamp does not light up rotate ballast slightly clockwise or counter clockwise 4 If lamp does not light up after rotating ballast replace lamp 5 If unit still does not light up after replacing lamp replace unit 6 REPLACEMENT PARTS LIST For replacement parts contact Field Controls at Phone 252 522 3031 Fax 252 522 0214 Email sales fieldcontrols com CLEAN U...

Страница 8: ...roof of purchase sales receipt identifying the Product purchased Product model or accurate date code information and the date the Product s was purchased 3 Product whose warranty quality stickers Product serial number plates or electronic serial numbers have been removed altered or rendered illegible shall not be covered under the limited warranty 4 Defective Product must be returned to Company po...