AIR CYCLES PER DAY

Fan unit on for 10 minutes per hour                  Air cycled(24) ------ times per day

Fan unit on for 15 minutes per hour                  Air cycled(31) ------ times per day

Fan unit on for 20 minutes per hour                  Air cycled(42) ------ times per day
Fan unit on for 30 minutes per hour                  Air cycled(63) ------ times per day

NOTE:

NOTE: In the event, the existing thermostat does not have the capability to operate the air-handler fan unit
independently of a demand for heating or air-conditioning, it is highly recommended to install the Field Controls
Healthy Home System Control PLus (HHSC+) programmable ventilation system.

This device is simply wired in parallel with the existing thermostat and can be programmed to turn on the air
handler fan unit for any desired interval. A memory tracks the time the fan unit operates every hour and only
cycles the fan unit that hour if normal requirements for heating and air conditioning have not cycled the fan unit
long enough to meet air purifi cation requirements.

COST OF CONTINUOUS (24) HR PER DAY OPERATION PER MONTH

 

 

 

Electricity cost 

 

 

 

per kilowatt hour                   .06 kw hr.           .08 kw hr.            .10 kw hr.

 

 

 

TRIO (32.25 kw hours)

 

 

 

cost per month                           $1.93                   $2.58                    $3.22

During periods where the fan unit is being operated for the sole purpose of air purifi cation, usually during
the spring and fall season when there is no requirement for heating or cooling, the cost of running a 1/2
horsepower fan unit will add approximately $5.36 per month to the normal operating cost. However, this cost is
easily offset in savings on medication, doctors offi ce visits, mechanical maintenance and cleaning of fan units,
refrigeration coils, dirty air ducts and last but not least, less house cleaning.

SERVICE

The Trio 1200/2000 Healthy Home Purifi cation System has serviciable components.

MERV13 Filter. . . . . change every (6 to 12) months .

UVC germicidal Lamps . . . . . change every (12) months . 

CHANGING THE PARTICULATE REMOVAL CARTRIDGE (FILTER)

1.    Unplug the power cord from the Trio 1200/2000 Healthy Home Purifi cation System. Unscrew the two  
       locking  knobs and remove the door. (Fig. 1)

2.    Remove old fi lter cartridge and replace with new fi lter. Make sure airfl ow arrow on fi lter is pointing to the 
       inside of module. (Fig. 2)

Содержание Healthy Home System

Страница 1: ...HEALTHY HOME AIR PURIFICATION SYSTEM MODELS TRIO 1200 TRIO 2000 INSTALLATION AND OPERATION Field Controls 2630 Airport Road Kinston NC 28504 252 522 3031 www fieldcontrols com ...

Страница 2: ...ave ultraviolet light during period of non air flow and is self cleaning If there is build up blocking the catalytic cells sit the unit on end on a flat surface with electrical enclosure facing up Use low pressure compressed air to blow the surface of the catalytic cells free of blockage Do not install insulation within 76MM or 3 inches of Luminaries Access for service is required when mounting abov...

Страница 3: ...ctivating itself during periods of non use or no airflow The cost of operation is less than 07 cents per day See operating cost section The Trio 1200 2000 air purification system combines three unique technologies to protect people against indoor air pollutants Photo catalytic technology PCO combined with high efficiency electro statically super charged MERV13 particulate filter and UVC germicidal lig...

Страница 4: ... COST OF CONTINUOUS 24 HR PER DAY OPERATION PER MONTH Electricity cost per kilowatt hour 06 kw hr 08 kw hr 10 kw hr TRIO 32 25 kw hours cost per month 1 93 2 58 3 22 During periods where the fan unit is being operated for the sole purpose of air purification usually during the spring and fall season when there is no requirement for heating or cooling the cost of running a 1 2 horsepower fan unit wi...

Страница 5: ...Fig 4 3 Unplug UVC germicidal lamps loosen retaining knobs and remove UVC germicidal lamps Fig 5 6 4 Replace UVC germicidal lamps re tension retaining knobs and replace plug ins 5 Replace Photocatalytic module and filter secure door and re insert power cord check view ports to ensure lamp illumination NOTE NOTE Ensure filter and photocatalytic module are installed in proper air flow sequence FIG 3 FI...

Страница 6: ...n sheet doc 78010001000 This document is available on the Field Con trols Web Site www FieldControls com The Healthy Home iAQ APP is a free down load from Apple Store or Google play for your mobile device Search Healthy Home iAQ Healthy Home System Control Plus HHSC Healthy Home System Control Plus HHSC will automatically alert the homeowner via HHSC status LED will turn red and display on the scr...

Страница 7: ...nobs and remove the inside module from the outer case 2 Take care not to bend or distort the outer metal enclosure 3 Mount the outer case to the support plenum NOTE NOTE Do not use a screw length that will extend into or penetrate the inside module containing the TiO2 catalyst or filter cartridge 4 In some cases the foot print of the air handler may be larger or smaller than the outer enclosure of ...

Страница 8: ... the inner module into the outer encasement and tighten locking knobs finger tight Make sure the inner module will freely slide in and out of the outside enclosure 8 Plug in the power cord to any 120vac outlet and check both sight ports to make sure both lamps are illuminated Ultraviolet lamps must remain on at all times regardless of thermostat or HHSC Control settings 9 Set the thermostat or the ...

Страница 9: ...page 9 Designed in accordance with UL 1598 and CAN CSA C22 2 ...

Страница 10: ...page 10 FIG 10 Electrical Diagram WIRING DIAGRAM PRODUCT LABEL PLACEMENT Label is shipped in bagged parts seperately and should be placed on unit as noted below ...

Страница 11: ...page 11 Denotes transformer installed on product shipped prior to 2016 ...

Страница 12: ...hone 252 522 3031 Fax 252 522 0214 www fieldcontrols com Field Controls LLC P N 46638700 Rev K 09 18 WARRANTY For warranty information about this or any Field Controls product visit www fieldcontrols com ...

Отзывы: