SPECIFICATIONS

Model Trio 1200:

(Capacity 1-1/2 to 3.0 tons)
MFG: Field Controls
Model: Trio 1200
Power: 120V/60 Hz .6 Amps 49.2 Watts
Fuse: Replace only with AGC-2 fuse
Application: 3 Ton Drive Air Handler / Furnace
Max Face Velocity: 500 FPM
Max Air Flow: 1200 CFM
Service: UVC Lamps - 1 year / Filter – 6/12 months
Replace: UVC germicidal lamps with Part# 22LAMP
Replace: Filter with Part# TrioRM13-1625 MERV13
U.V. Range: 254 NM (germicidal)
Catalyst: Metal Oxides 56 Sq. Feet
Weight: 23 LBS
Dimensions: 17” H x 25” W x 10” D

Model Trio 2000:

(Capacity 3.5 to 5.0 tons)
MFG: Field Controls
Model: Trio 2000
Power: 120V/60 Hz .6 Amps 49.2 Watts
Fuse: Replace only with AGC-2 fuse
Application: 5 Ton Drive Air Handler / Furnace
Max Face Velocity: 625 FPM
Max Air Flow: 2000 CFM
Service: UVC Lamps - 1 year / Filter – 6/12 months
Replace: UVC germicidal lamps with Part# 22LAMP
Replace: Filter with Part# TrioRM13-2025 MERV13
U.V. Range: 254 NM (germicidal)
Catalyst: Metal Oxides 70 Sq. Feet
Weight: 26 LBS
Dimensions: 21” H x 25” W x 10” D

OPERATION

The Trio 1200/2000 Healthy Home Purifi cation System installs in the air-inlet side of any heating and airconditioning 
system up to fi ve tons in size. Only operation of the air-handler fan unit is required for air purifi cation and steriliza-
tion to take place.

NOTE: 

NOTE: The UVC germicidal lamps are wired to operate continuously. This feature allows the catalyst to burn off 
surface impurities, cleaning and reactivating itself during periods of non-use or no airfl ow. The cost of operation is 
less than .07 cents per day. See operating cost section.

The Trio 1200/2000 air purifi cation system combines three unique technologies to protect people against indoor air 
pollutants. Photo catalytic technology (PCO) combined with high effi ciency electro-statically super charged MERV13 
particulate fi lter and UVC germicidal light quickly reduces and eliminated toxic gas-phase chemicals, lung damaging 
dust and airborne germs from the living environment.

Many new homes have smart programmable thermostats that allow for automatic operation of the air-handler fan
unit when there is no demand for heating or air conditioning. It is important that the TRIO 1200/2000 Healthy Home 
Purifi cation System is operating at least 20-30 minutes per hour (24) hours per day to remove toxic materials from 
the indoor environment.

The length of operation depends on the location of the home or offi ce in relation to point source pollution such as
refi neries, processing plants, automobile traffi c and areas that produce high levels of pollen. Individuals that are sen-
sitive to mold spores, dust mites, chemicals or have respiratory problems such as asthma, emphysema, and chronic 
allergies should extend the run time to (40) minutes or more per hour.

AIR CYCLES PER HOUR

(Based on 3000 sq. ft.)

Fan unit on for 10 minutes per hour Air cycled(1) ------- times per hour

Fan unit on for 15 minutes per hour Air cycled(1.3) ----- times per hour

 Fan unit on for 20 minutes per hour Air cycled(1.75) ---- times per hour

  Fan unit on for 30 minutes per hour Air cycled(2.62) ---- times per hour

Содержание Healthy Home System

Страница 1: ...HEALTHY HOME AIR PURIFICATION SYSTEM MODELS TRIO 1200 TRIO 2000 INSTALLATION AND OPERATION Field Controls 2630 Airport Road Kinston NC 28504 252 522 3031 www fieldcontrols com ...

Страница 2: ...ave ultraviolet light during period of non air flow and is self cleaning If there is build up blocking the catalytic cells sit the unit on end on a flat surface with electrical enclosure facing up Use low pressure compressed air to blow the surface of the catalytic cells free of blockage Do not install insulation within 76MM or 3 inches of Luminaries Access for service is required when mounting abov...

Страница 3: ...ctivating itself during periods of non use or no airflow The cost of operation is less than 07 cents per day See operating cost section The Trio 1200 2000 air purification system combines three unique technologies to protect people against indoor air pollutants Photo catalytic technology PCO combined with high efficiency electro statically super charged MERV13 particulate filter and UVC germicidal lig...

Страница 4: ... COST OF CONTINUOUS 24 HR PER DAY OPERATION PER MONTH Electricity cost per kilowatt hour 06 kw hr 08 kw hr 10 kw hr TRIO 32 25 kw hours cost per month 1 93 2 58 3 22 During periods where the fan unit is being operated for the sole purpose of air purification usually during the spring and fall season when there is no requirement for heating or cooling the cost of running a 1 2 horsepower fan unit wi...

Страница 5: ...Fig 4 3 Unplug UVC germicidal lamps loosen retaining knobs and remove UVC germicidal lamps Fig 5 6 4 Replace UVC germicidal lamps re tension retaining knobs and replace plug ins 5 Replace Photocatalytic module and filter secure door and re insert power cord check view ports to ensure lamp illumination NOTE NOTE Ensure filter and photocatalytic module are installed in proper air flow sequence FIG 3 FI...

Страница 6: ...n sheet doc 78010001000 This document is available on the Field Con trols Web Site www FieldControls com The Healthy Home iAQ APP is a free down load from Apple Store or Google play for your mobile device Search Healthy Home iAQ Healthy Home System Control Plus HHSC Healthy Home System Control Plus HHSC will automatically alert the homeowner via HHSC status LED will turn red and display on the scr...

Страница 7: ...nobs and remove the inside module from the outer case 2 Take care not to bend or distort the outer metal enclosure 3 Mount the outer case to the support plenum NOTE NOTE Do not use a screw length that will extend into or penetrate the inside module containing the TiO2 catalyst or filter cartridge 4 In some cases the foot print of the air handler may be larger or smaller than the outer enclosure of ...

Страница 8: ... the inner module into the outer encasement and tighten locking knobs finger tight Make sure the inner module will freely slide in and out of the outside enclosure 8 Plug in the power cord to any 120vac outlet and check both sight ports to make sure both lamps are illuminated Ultraviolet lamps must remain on at all times regardless of thermostat or HHSC Control settings 9 Set the thermostat or the ...

Страница 9: ...page 9 Designed in accordance with UL 1598 and CAN CSA C22 2 ...

Страница 10: ...page 10 FIG 10 Electrical Diagram WIRING DIAGRAM PRODUCT LABEL PLACEMENT Label is shipped in bagged parts seperately and should be placed on unit as noted below ...

Страница 11: ...page 11 Denotes transformer installed on product shipped prior to 2016 ...

Страница 12: ...hone 252 522 3031 Fax 252 522 0214 www fieldcontrols com Field Controls LLC P N 46638700 Rev K 09 18 WARRANTY For warranty information about this or any Field Controls product visit www fieldcontrols com ...

Отзывы: