background image

 

Page 2

HOW IT WORKS 

Pure water contains nothing but H

2

0.  But water, as it comes out of the ground, is rich in a multitude of minerals.  Minerals 

such as calcium and magnesium are the main components of hard water, and the cause of scale formation and other 
problems. 

There are three basic methods used to control the problem of hardness and specifically scale formation. 

I

ON 

E

XCHANGE

One method is to remove the calcium and magnesium from the water through ion exchange (the traditional water 
softener).  This method requires the use of a resin filled tank with a high concentration of salt ions.  As the water flows 
through the resin tank the salt ions (typically sodium) are exchanged for the calcium or magnesium ions.  This lowers the 
concentration of the minerals that cause scale and therefore inhibits scale formation. 

C

HEMICAL 

A

DDITION

A second method used to control hard water scale is the addition of chemicals (such as phosphates) to the water.  These 
materials chemically alter the scaling characteristics of the calcium or magnesium, allowing the concentration of the 
minerals to stay the same while still reducing scale formation and its affects. 

Both of the above methods require the use of consumable materials to change the makeup of the water.  For these 
devices to function properly, the homeowner must continuously replenish the salts or chemicals as well as perform 
periodic maintenance on the equipment.  In addition to these inconveniences, the chemicals and salts discharged into the 
effluent water present problems downstream to the municipal water treatment facility and the environment.  Many U.S. 
cities have been enacting and/or evaluating environmental legislation to limit or reduce the levels of chemicals or salts that 
result from these types of water treatment methods. 

E

LECTRIC 

P

OTENTIAL

A third method used to treat the hard water problems associated with scale utilizes changes in electrical potential in the 
water to produce the affects of chemical addition.  The electric potential applied changes the scaling characteristics of the 
calcium or magnesium without the removal of these ions or the addition of chemicals. 

Magnets  

Bar magnets were the first types of equipment used to generate electric potential changes in water.  Bar magnets have 
been used with limited success to inhibit scale formation.  The fixed magnetic field of a bar magnet creates electric 
potential changes in the water only when the water moves through the magnetic field.  Electromagnets function in much 
the same way as bar magnets, but the magnetic field is created by passing a current through a coil, essentially creating a 
more powerful fixed magnetic field.  Inherently, fixed magnetic fields are limited to a narrow range of applications, pipe 
sizes and water flow rates.  

Permanent bar magnets and electromagnets have been promoted as a method of “treating” hard water, but they do not 
treat the vast and complex array of mineral contents and concentrations found in water.  Particles can also build up inside 
the pipe where the magnet is placed, eventually causing blockage at the very point it is supposed to be doing its job.

 

Electrostatic Devices 

Electrostatic devices create an electric potential in the water between two electrodes.  One electrode is mounted in the 
water stream in the center of the pipe housing, while the pipe itself acts as the other electrode.  The device applies a 
voltage across the two electrodes to create the electric potential in the water.  This electrostatic approach was an 
improvement upon the bar magnets and electromagnets, but increased the initial cost considerably while not dramatically 
improving the range of effective conditions. 

ClearWave™ 

The ClearWave™ water conditioning system operates on similar principles as the magnets and electrostatic devices.  But 
unlike those previously mentioned, the ClearWave™ uses microprocessor technology to electronically generate inaudible 
wave-forms which help keep calcium carbonate particles (scale) dissolved or suspended in water.  With ClearWave™, the 
electric field generated is always being applied to the water, while a magnetic field relies on the movement of water to 
produce the electric potential changes.   

Содержание CLEARWAVE CW-HD-1

Страница 1: ...o magnetic low frequency wave pulses into the water These wave pulses produce water with remarkable anti scale properties without adding salts or chemicals at an operating cost for electricity of appr...

Страница 2: ...ric potential applied changes the scaling characteristics of the calcium or magnesium without the removal of these ions or the addition of chemicals Magnets Bar magnets were the first types of equipme...

Страница 3: ...n soluble and insoluble causes a disruption and weakening of the electrical field reducing the effectiveness on scale reduction Under these conditions an iron removal system is required to filter out...

Страница 4: ...1 One set of mounting brackets are provided for mounting the ClearWave onto 1 2 to 1 1 2 water pipes or wall mounted near the selected pipe area Mount the mounting brackets to the base of the ClearWa...

Страница 5: ...tom of the pipe first keeping the antenna wire tight against the pipe and the preceding coil Secure the end of the left antenna wire to the water pipe with a wire tie 3 When energized the ClearWave mo...

Страница 6: ...sired temperature After 1 to 2 months Any scaly crust or stains in toilets or under taps should be significantly reduced No new stains or crust should form Mold that attaches to scale will begin to di...

Страница 7: ...Page 7...

Страница 8: ..._____ _______________________________ _______________________________ _______________________________ _______________________________ _______________________________ _______________________________ __...

Отзывы: