4. Remove the four nuts securing the motor assembly, and pull the motor assembly straight off of the unit. (See Figure
18)
5. Clean off any build-up inside the blower wheel housing and the blower wheel. CAUTION: Avoid applying excess pres-
sure on the blower wheel when cleaning off any build-up of material. This will cause an imbalance of the blower wheel
which will result in excessive vibration and premature motor failure.
I
NSTALLATION
1. Align the holes in the circular cover plate with the holes in the motor mount bracket on the motor assembly. (See
Figure 17)
2. Slide the motor assembly onto the protruding threaded studs on the venter body with the exhaust chute pointing
downward, and replace the four nuts securely to the threaded studs.
3. Reattach the flexible conduit and wires to the motor and secure the cover on the electrical box.
4. Install the motor cover with the side louvers pointing downward.
INITIAL BURNER AND VENTING SYSTEM OPERATIONAL INFORMATION
List the following for each operating appliance on the sidewall venting system, as a guide for tune-up or service
information annually.
DATE:
Heating Appliance BTU/HR Input
Gas Valve Operation Pressure
Vent System Draft Above Draft Hood
CO
2
Measurement
CO Measurement
Equipment Outlet Flue Gas Temperature