Page 4
WIRING INSTRUCTIONS
Wire the venter motor and controls in accordance with the National Electrical Code, manufacturer's recommendations and/or
applicable local codes. UNIT MUST BE GROUNDED. Check ground circuit to make certain that the unit has been properly
grounded. The wiring should be protected by an over current circuit device rated at 15 amperes. CAUTION must be taken to
ensure that the wiring does not come into contact with any heat source. All line voltage and safety control circuits, between the
venter and the appliance, MUST be wired in accordance with the National Electrical Code for Class I wiring or equivalent
methods.
Route the venter motor and control wiring with an appropriate wiring method. Refer to the Wiring Diagrams A through E.
Diagram A
–
Oil Fired System: Single Unit Wiring
Содержание 46149200
Страница 5: ...Page 5 Diagram B Oil Fired System Wiring with Electronic Primary ...
Страница 6: ...Page 6 Diagram C Typical Wiring for Oil Fired Warm Air Furnace with a Honeywell ST9103 Control Board ...
Страница 7: ...Page 7 Diagram D Riello Burner Application ...
Страница 8: ...Page 8 Diagram E Multiple Oil Fired Systems ...
Страница 12: ...Page 12 P N 46149200 Rev E 11 05 ...