FM180 

 

DIGITAL WEIGHING INDICATOR 

 
 

OPERATION MANUAL 

 
 

 

PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE 

ATTEMPT TO OPERATE THIS INSTRUMENT 

 
 

 

 
 
 
 
 
 
 
 

 
 

Specifications subject to change without prior notice 

 

V100  December  2012 

 

Содержание FM180

Страница 1: ...180 DIGITAL WEIGHING INDICATOR OPERATION MANUAL PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE ATTEMPT TO OPERATE THIS INSTRUMENT Specifications subject to change without prior notice V100 December 201...

Страница 2: ...2...

Страница 3: ...with Weighing Platform or Load Cell Junction Box 11 4 4 Connecting RS232 To Computer 12 4 5 Connecting RS232 to Printer DB25 12 5 Initial Setup 13 5 1 Internal Settings 13 5 2 How to Enter Select Inte...

Страница 4: ...t Receipt Printing 25 8 1 Standard Print Output Format 25 8 2 Custom Print Output Format 27 9 Label Printing LP 50 or Compatible 30 9 1 Label Format Groups Label File Names 30 9 2 Label Programming 31...

Страница 5: ...ore information and after sales service 1 3 Warm up time a Allow warm up period of not less than 60 seconds before calibration The higher the setup resolution of the scale the longer the warm up perio...

Страница 6: ...6 2 Specifications...

Страница 7: ...7 3 Keys Display Connections...

Страница 8: ...to shift among various weight units if weight unit conversation is enabled 6 Print Key1 Press this key to print the results to a computer or a printer through the RS 232 output 7 MR Key Press this key...

Страница 9: ...eading shown is net value 15 Stable Indicator Visible when weight reading is stable 16 Zero Indicator Visible when instrument is at true zero weight status 17 M Indicator Visible when memory contains...

Страница 10: ...Recharging battery Green color Charging completed A DC Jack Input for Indicator External power adaptor is plugged in here Output requirements of the power adaptor DC9 12V 800mA Polarity Any kind B Bl...

Страница 11: ...tallation exist 4 1 Built In Rechargeable Battery The instrument is equipped with a built in rechargeable battery Before first time use recharge it for at least 8 hours to ensure the best battery perf...

Страница 12: ...N ve 4 SENSE ve 5 SIGNAL ve 6 SIGNAL ve 7 GROUND 4 4 Connecting RS232 To Computer RS232 COMPORT ON INSTRUMENT COM PORT ON COMPUTER DB9 DB25 2 RXD 3 TXD 3 TXD 3 TXD 2 RXD 2 RXD 5 GND 5 GND 7 GND 4 5 Co...

Страница 13: ...unctions are usually for dealer and authorized personnel only Do not change any settings of these functions to avoid operation errors 5 2 How to Enter Select Internal Function Follow the below steps t...

Страница 14: ...ountdown or set F1 value being shown to zero and to display the net span gain by applying additional load applied Func Goto next page Move cursor to one place right Unit Goto previous page Move cursor...

Страница 15: ...15...

Страница 16: ...16...

Страница 17: ...17...

Страница 18: ...18...

Страница 19: ...applied to platform may cause damages to the weight sensor c The weight of the object is displayed automatically d It is a good practice to remove all loads from platform after weighing It will prolon...

Страница 20: ...hat the Zero Indicator is on If not press Zero c Place container on platform d Press Tare e Net Indicator appears to indicator tare is in effect and weight displayed display is net weight f To cancel...

Страница 21: ...weight can be entered via keyboard To enable this function set F63 to ON then set also F12 to OFF a During normal operation press Func until PtArE appears then press Print to enter Input the pre deter...

Страница 22: ...arance a Press MR to recall total accumulated weight from memory After MR is pressed Mr Indicator appears to indicate the total accumulated weight value is displayed At the same time instrument displa...

Страница 23: ...e same quantity as being displayed on this instrument18 and press Print c This instrument will calculate store the average piece weight and confirm with 2 beeps The quantity applied to platform is the...

Страница 24: ...ode There are 3 data output modes are available20 Mode 1 and Mode 2 are for communication with computer and other peripherals which accepts and processes continuous data communication Mode 3 is for tr...

Страница 25: ...internal function F18 8 1 Standard Print Output Format23 24 Standard ticket receipt printout of various function modes are illustrated below Press PRINT for manual output or set F17 ON for automatic o...

Страница 26: ...16 DATE 14 04 2009 NO 2 Second transaction added to memory NET 200 0kg TARE 0 0kg GROSS 200 0kg TOTAL 700 0kg Total accumulated net weight Sample 3 TIME 15 21 25 DATE 14 04 2009 NO 3 Third transactio...

Страница 27: ...ariants Table for more detail 8 2 1 To Edit Custom Print Output Format Follow the below steps to create custom printout a Go to internal function and select the desired function number to edit b Selec...

Страница 28: ...2 This instrument will automatically add End on line number 15th for Weighing Piece Count and Percentage function and on line number 10th for animal weighing function 8 2 2 Print Output Format Variant...

Страница 29: ...29 NET 200 0kg 3 nEt TARE 0 0kg 4 tArE GROSS 200 0kg 5 GroSS Blank line 6 Cr LF Signature 7 SiGn 8 End...

Страница 30: ...rong data of non current working mode 9 1 Label Format Groups Label File Names 2 label format groups are available these are for 2 label format group 1 and For 2 label format group 1 9 1 1 For 1 Label...

Страница 31: ...rint label file BB1 dlb stored in printer For 2 2 Select this to print label file BB2 dlb stored in printer For 2 3 Select this to print label file BB3 dlb stored in printer For 2 4 Select this to pri...

Страница 32: ...transaction Weighing 7 N Total accumulated weight Weighing 9 O Net weight All 10 P Tare weight All 10 Q Gross weight All 10 U Number of piece Piece Count 10 V Average piece weight Piece Count 9 9 2 2...

Страница 33: ...33 9 2 2 2 Sample Label of Totalized Data For 2...

Страница 34: ...s at low voltage status It is recommended to recharge as soon as possible To protect the built in rechargeable battery this instrument will be powered off automatically when battery is at extremely lo...

Страница 35: ...on Err 5 No load cell signal detected Err 6 Tare operation error Err 7 Reserved no definition Err 8 Reserved no definition Err 9 Reserved no definition Err 10 Reserved no definition Err 11 Reserved n...

Страница 36: ...cetone volatile solvent thinner or alcohol for cleaning Verify the accuracy of this instrument periodically Re calibrate if necessary In some countries calibration requires authorized qualified agent...

Страница 37: ...f the Windows operating system in computer A Direct Control Commands30 F18 Mode 1 or 2 Equivalent direct control commands for each of the key on panel from computer are shown below Note There is no di...