6
.
www.fidelissecurity.com
Copyright © 2022 Fidelis Cybersecurity
®
, Inc. All rights reserved
2. Specify the credentials:
‒
Username - Administrator
‒
Password - A random eight-character string
‒
DNS name - ILOXXXXXXXXXXXX, where the X characters represent the server serial
number.
The iLO firmware is configured with a default username, password, and DNS name. The default
information is on the serial label pull tab attached to the server that contains the iLO management
processor. Use these values to access iLO remotely from a network client by using a web
browser.
3. In the iLO web interface, navigate to
iLO Integrated Remote Console
.
4. Select
Power & Thermal
.
5. Click
Reset
.
The system shuts down and restarts. For Fidelis Network appliances version 9.4.1 or later, a
screen similar to below is displayed. If you do not see this screen, contact Fidelis Customer
Support.
6. Continue with
Complete the Appliance Network Configuration
Configuring iLO to Use a Static IP Address
Use this procedure only if you want to connect to the component CLI using iLO and you need a static IP
address. Note that iLO supports DHCP by default.
1. Directly attach an ethernet cable from a client system, such as a laptop to the iLO port on the
appliance.
2. Restart the machine.
3. Press F9 in the server POST screen.
The UEFI System Utilities start.
4. Click
System Configuration
.
5. Click
iLO 5 Configuration Utility
.
6. Disable DHCP:
a. Click
Network Options
.
b. Select
OFF
in the
DHCP Enable
menu.
The
IP Address
,
Subnet Mask
, and
Gateway IP Address
boxes become editable. When DHCP
Enable is set to
ON
, you cannot edit these values.
7. Enter values in the
IP Address
,
Subnet Mask
, and
Gateway IP Address
boxes. (See