6. Appliance Installation 

Rack Installation 

Install each appliance in an enclosure/location that has necessary power and cooling. Ensure that the 
installation environment is within the operating temperature of the appliance. See 

Appendix B

 for 

appliance operating temperature requirements. 

Power 

Connect power cables to the power supplies in the back of the appliance. See 

Appendix B

 for appliance 

power requirements. 

Network Cabling 

Using the connectors and cables described in sections 3 and 4, begin to connect the appliances to the 
networks. Cable the Collector SA appliance(s) to the switches: 

1.  Connect the Admin (eth0) port to the Admin switch port. 

2.  Optionally, connect the iLO port to the Admin (or iLO) switch port. 

7. Appliance Network Configuration 

Start the Appliance Network Configuration 

1.  Power on the appliance(s). 

2.  Connect to the component CLI using either of the following: 

 

Via KVM Console. se

Option 1: Connect to the Component CLI Using KVM Console

 

 

Via iLO, see 

Option 2: Connect to the Component CLI Using iLO

 

Option 1: Connect to the Component CLI Using KVM Console 

1.  Connect a keyboard and monitor to the appliance. 

2.  Continue wit

Complete the Appliance Network Configuration

 

Option 2: Connect to the Component CLI Using iLO 

iLO supports DHCP by default. If you need a static IP address, before performing this procedure, first 
follow 

Configuring iLO to Use a Static IP Address

. 

1.  Log into the iLO console: 

https://<

IP address

where <

IP address

> is the iLO IP address 

Содержание Network Collector SA

Страница 1: ...ze attackable surface areas automate exposure prevention threat detection and incident response and provide the context accuracy speed and portability security professionals need to find and neutralize adversaries earlier in the attack lifecycle Fidelis Cybersecurity is dedicated to helping clients become stronger and more secure Fidelis is trusted by many top commercial enterprise and government ...

Страница 2: ... video monitor KVM switch for temporary appliance setup Power cables two per appliance appropriate power source and region Ethernet cables cat5e for Admin and iLO ports Section 3 Network switches with enough physical ports Section 4 Logical network information IP addresses hostnames Section 5 Appendix A For Fidelis software version 9 4 1 and later the appliance type Appendix C 2 Documentation Pass...

Страница 3: ... Toll free in the US and Canada 1 800 652 4020 Email support fidelissecurity com Web https support fidelissecurity com 3 Collector SA Network Port and Cabling Requirements You must connect each appliance to the various networks using appropriate cables and in some cases SFP transceivers The table below describes the physical connection and cable type associated with each port on the appliance Coll...

Страница 4: ...r SA GbE Copper RJ45 port 1 iLO IPMI Network The iLO IPMI network is an optional network for remote out of band server administration Appliance Switch Port Type Qty Collector SA GbE Copper RJ45 port 1 5 Appliance Logical Network Configuration You must assign logical network information to each physical connection Build a table of the logical information for each appliance sample below that you can...

Страница 5: ...ches 1 Connect the Admin eth0 port to the Admin switch port 2 Optionally connect the iLO port to the Admin or iLO switch port 7 Appliance Network Configuration Start the Appliance Network Configuration 1 Power on the appliance s 2 Connect to the component CLI using either of the following Via KVM Console see Option 1 Connect to the Component CLI Using KVM Console Via iLO see Option 2 Connect to th...

Страница 6: ...r later a screen similar to below is displayed If you do not see this screen contact Fidelis Customer Support 6 Continue with Complete the Appliance Network Configuration Configuring iLO to Use a Static IP Address Use this procedure only if you want to connect to the component CLI using iLO and you need a static IP address Note that iLO supports DHCP by default 1 Directly attach an ethernet cable ...

Страница 7: ...mately 30 seconds 11 Resume the normal boot process a Start the iLO remote console The iLO 5 Configuration Utility is still open from the previous session b Press ESC several times to navigate to the System Configuration page c To exit the System Utilities and resume the normal boot process click Exit and resume system boot iLO is configured to use a static IP address Continue with Option 2 Connec...

Страница 8: ...ystem will automatically reboot 4 Directly attach an ethernet cable from a client system such as a laptop to the Admin eth0 port on the appliance The default IP address is 192 168 42 11 24 Assign a static IP from the same subnet to the network interface on the client system and connect to the appliance using SSH 5 Use the following credentials at the login prompt You will be required to change the...

Страница 9: ...st 1 From the CommandPost user interface navigate to Administration Components 2 Click Add Component 3 Fill in the Add New Component popup Component Type Select Collector Name Specify a friendly name for the Collector SA This is not the fully qualified domain name of the Collector SA Description Optionally specify a description for example a location business unit etc IP Address Specify the IP add...

Страница 10: ...lays the Configure Component popup b In the Configure Component popup select Direct Internal Mail or Web from the navigation on the left based on the type of sensor c Select the Advanced or Metadata tab d In the Send Metadata to Collector field select the Collector from the list Appendix A Network Configuration Worksheet Network Setting Assignments Interface Admin eth0 iLO IPMI Hostname FQDN Stati...

Страница 11: ...x HDD 300 GB RAID 1 6x HDD 1 2 TB RAID 10 3 6 TB Effective Network Adapters Default Config 4x 1GbE Out of Band Management Integrated Lights Out Management iLO Power Supply Dual hot swap 800W High Efficiency AC power supplies Dimensions H 4 29 cm 1 69 in W 43 46 cm 17 11 in D 70 7 cm 27 83 in Weight approx 16 27 kg 35 86 lb Operating Temperature 10 to 35 C 50 to 95 F at sea level AC Input Requireme...

Страница 12: ...e table below shows the software to apply based on the appliance SKU Note the SKU typically starts with FNH You can find the SKU in the following locations Appliance lid UID decal see sample on right Shipping carton decal see sample on right Packing list Purchase order Maintenance certificate Appliance SKU System Type FNH CollSA2 Collector SA ...

Страница 13: ...tures help minimize attackable surface areas automate exposure prevention threat detection and incident response and provide the context accuracy speed and portability security professionals need to find and neutralize adversaries earlier in the attack lifecycle Fidelis Cybersecurity is dedicated to helping clients become stronger and more secure Fidelis is trusted by many top commercial enterpris...

Отзывы: