Electrical Restrictions 

WARNING: 

This equipment is designed for connection to a grounded (earthed) outlet.  The grounding type plug 

is an important safety feature.  To reduce the risk of electrical shock, damage to your equipment, 
or loss of data, do not disable this feature. 

Power Cord Set Requirements 

The power cord set (appliance coupler, flexible cord, and wall plug) you received with the AquaPAD meets the 
requirements for use in the country where you purchased the equipment. 
Power cord sets for use in other counties must meet the requirements of the country where you use the AquaPAD. 
For more information on power cord set requirement, contact your local authorized dealer, reseller, or service 
provider.

 

General Requirements 

The requirements listed below are applicable to all countries: 
1.   The length of the power cord set must be at least 6.0 feet (1.8 m) and a maximum of 14.76 feet (4.5 m). 
2.   All power cord sets must be approved by an acceptable accredited agency responsible for evaluation in the 

country where the power cord set will be used. 

3.   The power cord set must have a minimum current capacity of 10A and a normal voltage rating of 125 or 250 

volts AC, as required by each country’s power system.

 

4.   The appliance coupler must meet the mechanical configuration of an EN 60320. / IEC 320 Standard Sheet C13 

connector, for mating the appliance inlet on the AquaPAD.

 

Country-Specific Requirements 

Power Cord Set Requirement 

Country

 

Accredited Agency

 

Applicable Note Numbers

 

Australia EANSW 

Austria OVE 

Belgium CEBC 

Canada CSA 

Denmark DEMKO 

Finland FIMKO 

France UTE 

Germany VDE 

Italy IMQ 

Japan JIS 

The Netherlands 

KEMA 

Norway NEMKO 

Sweden SEMKO 

Switzerland SEV 

United Kingdom 

BSI 

United States 

UL 

Note:

 

1.  Flexible cord must be <HAR> Type HO5VV-F, 3-conductor. 1.0 mm

conductor size. Power cord set fittings 

(appliance coupler and wall plug) must bear the certification mark of the agency responsible for evaluation in the 
country where it will be used. 

2.  Flexible cord must be Type SVT or equivalent. No. 18 AWG, 3-conductor.  Wall plug must be a two-pole 

grounding type with a NEMA 5-15P (10A. 125V) or NEMA 6-15P (15A 250V) configuration.

 

3.  Appliance coupler, flexible cord, and wall plug must bear a “T” mark and registration number in accordance with 

the Japanese Dentori Law. Flexible cord must be Type VCT or VCTF, 3-conductor, 0.75mm

2

 conductor size. 

Wall plug must be a two-pole grounding type with a Japanese Industrial Standard C8303 (15A, 125V) 
configuration. 

Содержание AquaPAD

Страница 1: ...ne to report a gas leak in the vicinity of the leak 7 Slots and openings in the cabinet and the back or bottom are provided for ventilation to ensure reliable operation of the product and to protect i...

Страница 2: ...125 or 250 volts AC as required by each country s power system 4 The appliance coupler must meet the mechanical configuration of an EN 60320 IEC 320 Standard Sheet C13 connector for mating the applia...

Страница 3: ...ved feilaktig skifte av batteri Benytt samme batteritype eller en tilsvarende type anbefalt av apparatfabriknten Brukte batterier kasseres i henhold til fabrikantens instruksjoner 7 Finnish Paristo v...

Страница 4: ...quaPAD Internet Connection 10 Preparing the Power Supply 11 Using Battery 11 Using the AC DC Adapter 12 Chapter 3 13 Identifying the Parts 13 Front View 13 Right Side View 16 Top View 17 Rear View 18...

Страница 5: ...tem along with other multimedia applications AquaPAD s All in one design let users get connected anywhere any time with efficiency superior than ordinary PDAs Wireless Internet Access The build in Int...

Страница 6: ...ensures system will have the necessary power to operate when disconnected from external power Store the device in its cradle when not in use Battery Care Do not heat or attempt to disassemble a batter...

Страница 7: ...y AquaPAD in the Carrying Bag Optional or a protective case Do not check it with your luggage Do not use AquaPAD on an airplane The radio may function even though you are working off line Be aware of...

Страница 8: ...AquaPAD System User s Manual 8...

Страница 9: ...to keep it and all packing material for future shipping needs Unpacking the box make sure the following components are included in the box and are in good condition If you find that any of these compo...

Страница 10: ...er you are By inserting a PC card for wireless LAN application AquaPAD communicated with a matching wireless base station indirectly or directly to your Internet access mechanism for example analog ca...

Страница 11: ...s available using the AC DC adapter provided with the AquaPAD It is not necessary to access the battery pack except to replace a fresh battery pack To remove the battery pack follow these steps Turn o...

Страница 12: ...tioned for 3 times Using the AC DC Adapter If you prefer to operate the AquaPAD on AC power use the AC DC adapter that comes with this product Simply connect the power adapter into the DC in jack on t...

Страница 13: ...makes AquaPAD ideal for Internet browsing on the go Data can be entered from the touch screen using the stylus and soft keyboard The soft keyboard is displayed by clicking the bottom left area on the...

Страница 14: ...pplication For example in the Windows CE taskbar you may set the Sounds settings in the Start Settings Control Panel Sounds option Sound from the speaker is muted when a headphone is used 5 Volume Con...

Страница 15: ...dicator Middle The LED Indicator blinks and turns to green when system turns on 9 Battery charge Low Indicator Right The LED would be blinking amber constantly while battery is charging And the LED wo...

Страница 16: ...erience When a headset is inserted the sound to the speaker is bypassed 3 USB Port x 2 AquaPAD offers 2 USB ports located on the lower right edge A rubberized cover protects this port The USB port sup...

Страница 17: ...a PC card for Wireless LAN application 4 Expansion Socket CompactFlash TM Card Type I AquaPAD features a removable memory device called a CompactFlash TM Memory Card providing user accessible storage...

Страница 18: ...Crusoe processor allows up to 2 8 3 5 hours of battery life at full on operation with www access Rapid Charging Cradle Optional The AquaPAD includes a cradle into which the AquaPAD unit can be slotte...

Страница 19: ...Identifying the Parts 19 Figure 3 8 The Rapid Charging Cradle Figure 3 9 The Rapid Charging Cradle with battery...

Страница 20: ...the AquaPAD A rubberized cover protects this connector as shown in Figure 3 10 below Slide the latch from right to left orientation as shown in Figure 3 11 below Place the female connector of the Aqua...

Страница 21: ...Display TFT LCD 8 4 800 x 600 color TFT LVDS With Touchscreen portrait functon Battery Life 3600mAh 7 4V 4 cell Panasonic Lithium battery Battery Life 2 8 3 5 hours full on operation with www access a...

Страница 22: ...sium Alloy O S Midori Mobile Linux WinCE3 0 platform WinCE Platform Specification Item Feature Microsoft WinCE 3 0 Media player v6 4 embedded Pocket word embedded Internet Explorer 4 0 Inbox local e m...

Страница 23: ...ames PIM Calculator Calendar support sync Via IrDA Address Book support sync Via IrDA Note support sync Via IrDA Alarm Clock To Do List Utilities Pointer Calibration Printing Local and Remote optional...

Страница 24: ...hould happen to get inside the product immediately unplug the power cord Continuing to use the product can cause a fire or electrical shock Wipe off the plug of the power cord if it should become cove...

Страница 25: ...a and make sure to save your data in CF card regularly Question AquaPAD locks up when running applications or runs slowly Solution AquaPAD is locked up Close some applications those are not in use if...

Страница 26: ...ct sunlight can cause your AquaPAD s LCD screen to temporarily darken This is normal for LCD SCREENS AND IS NOT PERMANENT Question Display is difficult to see in sunlight or in dark rooms Solution Use...

Отзывы: