background image

 

1

Copyright 

Copyright © FIC (First International Computer). Corporation 2001.  All right reserved. 
Disclaimer: FIC Corporation shall not be liable for technical or editorial errors or omissions contained herein; nor for 
incidental or consequential damages resulting from furnishing this material, or the performance or use this product. 
FIC Corporation reserves the right to change product specification without notice.  Information in this document 
may change without notice. 
No part of this document may be copied, reproduced, or transmitted by any means, for any purpose without prior 
written permission from FIC Corporation. 

Safety Instructions

 

The AquaPAD has been tested for conformance to international safety regulations.  Like any electronic device, 
however, the AquaPAD should be used with care.  To protect yourself from possible injury and to minimize the risk 
of damage to the AquaPAD, read and follow these safety instructions: 

General Guidelines 

♦ 

Read all of these instructions. 

♦ 

Save these instructions for future use. 

♦ 

Follow all warnings and instructions marked in the AquaPAD. 

♦ 

Except as explained elsewhere in this manual, do not attempt to service the AquaPAD yourself.  Opening or 
removing covers that are marked “Do Not Remove” might expose you to dangerous voltage points or other risks.  
Refer all servicing of marked components to qualified personnel.

 

Installation Restrictions 

1.  Follow all warnings and instructions marked on the product. 

2.  Unplug this product from the wall outlet before cleaning.  Do not use liquid cleaners or aerosol cleaners.  Use a 

damp cloth for cleaning. 

3.  Do not use this product near water.  For example, near a bathtub, washbowl, kitchen sink or laundry tub, in a 

wet basement or near a swimming pool. 

4.  Do not place this product on an unstable cart, stand, or table.  The product may fall, causing serious damage to 

it. 

5.  Avoid using a telephone (other than a cordless type) during an electrical storm.  There may be remote risk of 

electric shock from lightning. 

6.  Do not use the telephone to report a gas leak in the vicinity of the leak. 

7.  Slots and openings in the cabinet and the back or bottom are provided for ventilation; to ensure reliable 

operation of the product and to protect it from overheating, these openings must not be blocked or covered.  The 
product should never be placed near or over a radiator or heat register, or in a built-in installation unless proper 
ventilation is provided. 

8.  This product should be operated from the type of power indicated on the marking label.  If you are not sure of 

the type of power available, consult your dealer or local power company. 

9.  Do not allow anything to rest on the power cord.  Do not locate this product where persons will tread on the cord. 

10.  If an extension cord is used with this product, make sure that the total ampere rating of the equipment plugged 

into the extension cord does not exceed the extension cord ampere rating.  Also, make sure that the total rating 
of all products plugged into the wall outlet does not exceed the fuse rating. 

11.  Never push objects of any kind into this product through cabinet slots as they may touch dangerous voltage 

points or short out parts that could resulting a fire or electronic shocks.  Never spill liquid of any kind on the 
product. 

12.  To reduce the risk of fire, use at least No. 26 AWG wire for the telecommunication line cord. 

13.  Always disconnect all telephone lines & all power cords from the wall outlet before servicing or disassembling 

this product.  And, refer it for servicing to qualified service personal under the following conditions: 

a.  When the power cord or plug is damaged or frayed. 

b.  If liquid has been spilled into the product. 

c.  If the product has been exposed to rain or water. 

d.  If the product does not operate normally when the operating instructions are followed.  Adjust only those 

controls that are covered by the operating instructions, since improper adjustment of other controls may 
result in damage and will often require extensive work by a qualified technician to restore the product to 
normal condition. 

e.  If the product has been dropped or cabinet has been damaged. 

f.  If the product exhibits a distinct change in performance, indicating a need for service. 

Содержание AquaPAD

Страница 1: ...ne to report a gas leak in the vicinity of the leak 7 Slots and openings in the cabinet and the back or bottom are provided for ventilation to ensure reliable operation of the product and to protect i...

Страница 2: ...125 or 250 volts AC as required by each country s power system 4 The appliance coupler must meet the mechanical configuration of an EN 60320 IEC 320 Standard Sheet C13 connector for mating the applia...

Страница 3: ...ved feilaktig skifte av batteri Benytt samme batteritype eller en tilsvarende type anbefalt av apparatfabriknten Brukte batterier kasseres i henhold til fabrikantens instruksjoner 7 Finnish Paristo v...

Страница 4: ...quaPAD Internet Connection 10 Preparing the Power Supply 11 Using Battery 11 Using the AC DC Adapter 12 Chapter 3 13 Identifying the Parts 13 Front View 13 Right Side View 16 Top View 17 Rear View 18...

Страница 5: ...tem along with other multimedia applications AquaPAD s All in one design let users get connected anywhere any time with efficiency superior than ordinary PDAs Wireless Internet Access The build in Int...

Страница 6: ...ensures system will have the necessary power to operate when disconnected from external power Store the device in its cradle when not in use Battery Care Do not heat or attempt to disassemble a batter...

Страница 7: ...y AquaPAD in the Carrying Bag Optional or a protective case Do not check it with your luggage Do not use AquaPAD on an airplane The radio may function even though you are working off line Be aware of...

Страница 8: ...AquaPAD System User s Manual 8...

Страница 9: ...to keep it and all packing material for future shipping needs Unpacking the box make sure the following components are included in the box and are in good condition If you find that any of these compo...

Страница 10: ...er you are By inserting a PC card for wireless LAN application AquaPAD communicated with a matching wireless base station indirectly or directly to your Internet access mechanism for example analog ca...

Страница 11: ...s available using the AC DC adapter provided with the AquaPAD It is not necessary to access the battery pack except to replace a fresh battery pack To remove the battery pack follow these steps Turn o...

Страница 12: ...tioned for 3 times Using the AC DC Adapter If you prefer to operate the AquaPAD on AC power use the AC DC adapter that comes with this product Simply connect the power adapter into the DC in jack on t...

Страница 13: ...makes AquaPAD ideal for Internet browsing on the go Data can be entered from the touch screen using the stylus and soft keyboard The soft keyboard is displayed by clicking the bottom left area on the...

Страница 14: ...pplication For example in the Windows CE taskbar you may set the Sounds settings in the Start Settings Control Panel Sounds option Sound from the speaker is muted when a headphone is used 5 Volume Con...

Страница 15: ...dicator Middle The LED Indicator blinks and turns to green when system turns on 9 Battery charge Low Indicator Right The LED would be blinking amber constantly while battery is charging And the LED wo...

Страница 16: ...erience When a headset is inserted the sound to the speaker is bypassed 3 USB Port x 2 AquaPAD offers 2 USB ports located on the lower right edge A rubberized cover protects this port The USB port sup...

Страница 17: ...a PC card for Wireless LAN application 4 Expansion Socket CompactFlash TM Card Type I AquaPAD features a removable memory device called a CompactFlash TM Memory Card providing user accessible storage...

Страница 18: ...Crusoe processor allows up to 2 8 3 5 hours of battery life at full on operation with www access Rapid Charging Cradle Optional The AquaPAD includes a cradle into which the AquaPAD unit can be slotte...

Страница 19: ...Identifying the Parts 19 Figure 3 8 The Rapid Charging Cradle Figure 3 9 The Rapid Charging Cradle with battery...

Страница 20: ...the AquaPAD A rubberized cover protects this connector as shown in Figure 3 10 below Slide the latch from right to left orientation as shown in Figure 3 11 below Place the female connector of the Aqua...

Страница 21: ...Display TFT LCD 8 4 800 x 600 color TFT LVDS With Touchscreen portrait functon Battery Life 3600mAh 7 4V 4 cell Panasonic Lithium battery Battery Life 2 8 3 5 hours full on operation with www access a...

Страница 22: ...sium Alloy O S Midori Mobile Linux WinCE3 0 platform WinCE Platform Specification Item Feature Microsoft WinCE 3 0 Media player v6 4 embedded Pocket word embedded Internet Explorer 4 0 Inbox local e m...

Страница 23: ...ames PIM Calculator Calendar support sync Via IrDA Address Book support sync Via IrDA Note support sync Via IrDA Alarm Clock To Do List Utilities Pointer Calibration Printing Local and Remote optional...

Страница 24: ...hould happen to get inside the product immediately unplug the power cord Continuing to use the product can cause a fire or electrical shock Wipe off the plug of the power cord if it should become cove...

Страница 25: ...a and make sure to save your data in CF card regularly Question AquaPAD locks up when running applications or runs slowly Solution AquaPAD is locked up Close some applications those are not in use if...

Страница 26: ...ct sunlight can cause your AquaPAD s LCD screen to temporarily darken This is normal for LCD SCREENS AND IS NOT PERMANENT Question Display is difficult to see in sunlight or in dark rooms Solution Use...

Отзывы: