Fiberstars WPC-04R Скачать руководство пользователя страница 7

 

 http://www.fiberstars.com 
79-15103-00 REV. B 

 

Page 7 of 11 

Flathead Screwdriver 

Repeater Mounting

 

The WPC-04R is equipped with a signal repeater that can be mounted up to 10 feet from the 
WPC-04R unit.  This repeater receives signals from the wireless remote and sends that signal to 
the WPC-04R via the 10 foot cable.  Establish a location for the Repeater that is in line of sight 
from where the wireless remote will be used most frequently and that is no more then 75 feet from 
furthest where the remote will be used.  NOTE:  If extension is needed, use Fiberstars part 
number 94-15098-00 and follow installation instructions supplied with the Repeater Extension. 
 
To mount the Repeater, carefully insert a small flathead screwdriver into groove between the 
Dome and Base approximately where the locking dimples are located.  Pry the Dome out of on of 
the locking dimples.  Then carefully insert the small flathead screwdriver into the groove between 
the Dome and the Base in an adjacent locking dimple and pry the Dome out.  Then separate the 
Dome from the Base by hand.  Using the supplied self-drilling screws, locate a suitable mounting 
surface and screw the base to this surface.  Note that the marking “TOP” must be in the 12 
o’clock position and the wire slit must be in the 6 o’clock position.  Do not over tighten the 
screws as it may damage the Repeater base.  Realign the Repeater Dome to the Base and ensure 
that the wire is exiting the base through the slit and the Locking Dimples are aligned with the 

10 feet 

Repeater 

Dome/Base groove 

Locking 
Dimple 

Orientation 
Marker 

Mounting 
Holes 

Base Slit for 
Repeater Wire 

Repeater Dome 

Repeater Base 

Mounting Screws 

Содержание WPC-04R

Страница 1: ...to UL STD 508 Certified to CSA STD C22 2 No 14 Installation Instructions Read these instructions in their entirety before performing any installation work Rated for use on 110 120VAC 60Hz and 220 240...

Страница 2: ...Length 5 1 37 15000 00 Relay 6 1 02 15287 00 Base Plate 7 1 02 15286 00 Timer and Switch Plate 8 1 02 15285 00 Relay Cover 9 1 38 15012 00 3 Position Rocker Switch 10 3 A10670 Screw 8 32 x 25 11 4 14...

Страница 3: ...or installation instructions Light circuit is rated for 8Amp 120VAC Max Basic safety precautions should be observed when operating the WPC 04R product and other associated equipment 1 A qualified elec...

Страница 4: ...common to the Timeclocks T C NEUTRAL In 20 Amp circuit breaker in the main breaker panel and connect the HOT wires from the WPC 04R in l es of in on to inal stall a inimum GFCI GROUND NEUTRAL 120V LIN...

Страница 5: ...oduct to the C 1 switch pull wires from the product WPC 04R through conduits connected to the bottom of the WPC 04R As illustrated connect the light that will be operated by the Rocker Switch to the L...

Страница 6: ...ONNECTING A 240VAC PUMP Connect the 240VAC pump to the relay as illustrated Connect the Line Power to a 240VAC Circuit Breaker on the breaker panel Circuit Breaker should be rated to correspond to Hor...

Страница 7: ...into groove between the Dome and Base approximately where the locking dimples are located Pry the Dome out of on of the locking dimples Then carefully insert the small flathead screwdriver into the g...

Страница 8: ...ch terminal To turn OFF the device manually flip the Rocker Switch to the MIDDLE or OFF position NOTE In the OFF position the wireless remote operation will be bypassed To re enable the wireless remot...

Страница 9: ...OTE Each tab represents 15 minutes of operation and tabs set inwards towards the center is for OFF operations and ON when the tabs are set outwards as illustrated In the example below the Pump will be...

Страница 10: ...http www fiberstars com For Freeze Protect Switch For Freeze Protect Switch 79 15103 00 REV B Page 10 of 11...

Страница 11: ...http www fiberstars com 79 15103 00 REV B Page 11 of 11...