Fiberstars FDS Скачать руководство пользователя страница 4

79-15167-00 REV. A 

www.fiberstars.com

 

Page 4 of 10 

FOR NEW INSTALLATIONS (FDS)

STEP 1.

Ensure that incoming power is DISCONNECTED at the circuit breaker BEFORE any 
electrical work is performed. 

STEP 2.

Place the supplied Brass base plate in accordance with National and Local electrical 
codes and ordinances for junction box placement (see illustration below for proper 
location and minimum spacing requirements). 

STEP 3.

The center conduit hub is equipped with a strain relief for a cord size of up to 10/3 AWG.
Only use with underwater lights equipped with water resistant cords. 

STEP 4.

Provisions for grounding terminals are provided for wires ranging from #16 AWG to #10 
AWG.  One equipment bonding terminal provision is provided and must be utilized for a 
#8 AWG insulated copper bonding wire.  Special considerations should be taken when 
attaching stranded grounding and bonding conductors to the supplied grounding and 
bonding screws, such as ring terminals rated for such applications. 

STEP 5.

Plug any unused conduit holes with the supplied conduit plugs. 

STEP 6.

Place the supplied rectangular gasket between the Brass base plate and the FDS adapter 
(Important Note: For upgrade installations discussed on the next page, assure to replace 
any existing gaskets with the supplied FDS gaskets). 

STEP 7.

There are three (3) wires in the FDS junction box for connection to underwater lights. 

a. Connect the WHITE wire to the common from the house common and from the 

common of the underwater light. 

b. Connect the BLACK wire from the sub-panel connected to an appropriately rated 

circuit breaker. 

c. Connect the RED wire to the LOAD wire of the underwater light. 

STEP 8.

Place FDS cover and round gasket onto the FDS adapter and Brass base plate. 

STEP 9.

Using the supplied screws, finger-tighten the screws from the FDS to the Brass base 
plate.

STEP 10. After all screws have been finger-tightened, completely tighten all screws in a cross 

pattern so that the FDS will seal properly. 

48” min. 

4” min. 

8” min. from bottom of J-Box 

to Top of Water Line 

18” min. from Water 

Line to top of Lens 

Rigid 
Conduit 

To GFCI, Circuit 
Breaker, and 
Power Source 

Содержание FDS

Страница 1: ...79 15167 00 REV A www fiberstars com Page 1 of 10 FDS FDS R FDS PS USER MANUAL 3091594 ETL LISTED Conforms to UL STD 1241 For use with 120V 60Hz input Output is 120V 60Hz at 5amps 600W MAX switched...

Страница 2: ...ircuit breaker 6 The FDS must be mounted at a minimum horizontally of 48 from edge of water 8 minimum vertically above water level and 4 minimum from the deck 7 The Light fixture and all metal items w...

Страница 3: ...NOTE ALREADY INSTALLED DO NOT REMOVE FDS COVER PRINTED CIRCUIT BOARD ASSEMBLY FOR REMOTE OPERATION NOTE ALREADY INSTALLED DO NOT REMOVE FDS ROUND GASKET FDS ADAPTER PLATE FDS RECTANGULAR GASKET BRASS...

Страница 4: ...ed for such applications STEP 5 Plug any unused conduit holes with the supplied conduit plugs STEP 6 Place the supplied rectangular gasket between the Brass base plate and the FDS adapter Important No...

Страница 5: ...pgrading from a Thermocraft JBP57510 remove the FDS Adapter STEP 6 Place the Adapter gasket onto the Thermocraft base plate STEP 7 Wire the FDS according to STEP 7 in the FOR NEW INSTALLATIONS section...

Страница 6: ...led within the 75 range of the remote transmitter STEP 2 Check the label of the FDS units to determine which operates on Circuit 1 and Circuit 2 STEP 3 To complete the installation follow instructions...

Страница 7: ...itch is to test and trouble shoot the FDS x In the ON position the switch bypasses the FDS and turns on the light When in the ON position the Indicator Light should turn on at the same time x In the O...

Страница 8: ...from ON to OFF and vice versa For Synchronization operation simply push the SYNC ON OFF button NOTE If all circuits are off when the SYNC ON OFF button is pressed all circuits will be turned to ON If...

Страница 9: ...the Channel Code to match that of the FDS Reassemble the bottom cover to the top cover carefully Ensure that the bottom cover seats onto the top cover Screw down the mounting screws until they are snu...

Страница 10: ...ight fails to come on go to STEP 4 MANUAL ON POSITION Pool light comes ON 4 Move Rocker switch to ON position If pool light comes on FDS or Remote Control is the problem 4a Replace batteries on Remote...