background image

Page 11

Fiberlink® 5100 Series User’s Manual

Fiberlink® 5100 Series

Accessories and Related Products

Fiberlink® 6610 Visible Light Source

The Fiberlink® Visible Light Source provides a  
visible 650 nm laser output that can be used for  
identifying fiber breaks and individual fibers within  
fiber bundles, allowing for convenient, on-site  
testing of fiber networks during construction  
and maintenance procedures. 

Fiberlink® 6615 Optical Power Meter

The Fiberlink® Optical Power Meter measures the 
power of optical signals at 850, 980, 1310 and 1550  
nm wavelengths, allowing for convenient, on-site 
 testing of fiber networks during construction and 
maintenance procedures. It can be used to measure 
the power of an optical signal reaching the receiving 
end of a fiber optic cable, as generated either by a 
transmitter unit or by a light source such as the 6620.

Fiberlink® 6620  
Three Wavelength Light Source

The Fiberlink® Three Wavelength Light Source offers a 
laser output at wavelengths of 1310 and 1550 nm and 
VCSEL output at 850 nm, allowing for convenient,  
on-site testing of fiber networks during construction 
and maintenance procedures. 

Содержание 5102-B1L

Страница 1: ...A Tel 631 273 0404 Fax 631 273 1638 info commspecial com commspecial com Communications Specialties Fiberlink 5100 User s Manual Transmit 10 100 1000 Base T Ethernet over one or two single mode or mul...

Страница 2: ...ns Model Part Number Specifications 4 General Specifications 4 Operating Loss Budgets 5 Maximum Useable Distance 5 Ethernet Cable Requirements 5 Installation Instructions 6 Indicator LEDs 7 Operating...

Страница 3: ...tation that supports only half duplex the Fiberlink 5100 adapts to half duplex mode providing the nominal 1000 Mbps With high performance data transmission and easy installation the Fiberlink 5100 pro...

Страница 4: ...s 100Mbps 1488000pps 1000Mbps Cabling Maximum Distance See Optical Loss Budget Maximum Useable Distance sections of this manual Connectors Copper RJ 45 Auto MDI MDI X Fiber Optic LC type LEDs TX LINK...

Страница 5: ...annot estimate or guarantee operating loss budgets when the 5100 Series is used with other non Fiberlink devices Operating loss budget must not be exceeded Technical Specifications Optical Loss Budget...

Страница 6: ...k LED should illuminate 3 Connect any Category 3 4 or 5 Ethernet Cable to the Ethernet port of the receiver 5100 Series unit The TX Link LED should illuminate 4 Connect the fiber optic cable s to the...

Страница 7: ...s linked Blink RJ 45 Ethernet is active SPD On Speed is at 1Gbps Blink Speed is at 100Mbps Off Speed is at 10Mbps FD COL On Full Duplex Blink Collision occured Off Half Duplex FX LEDs Status Definitio...

Страница 8: ...too much attenuation Next be certain that the input and output signal connections are correct If the FX Link LED fails to illuminate and you are using a two fiber system reverse the fiber optic conne...

Страница 9: ...ight transmission and that electrical connections are secure and accurate Please see the Troubleshooting section of this manual for additional information An optical power meter such as the Fiberlink...

Страница 10: ...option to either the repair or replacement of defective units including free materials and labor In no event shall CSI be responsible for any incidental or consequential damages or loss of profits or...

Страница 11: ...Power Meter measures the power of optical signals at 850 980 1310 and 1550 nm wavelengths allowing for convenient on site testing of fiber networks during construction and maintenance procedures It ca...

Страница 12: ...638 info commspecial com commspecial com 2014 Communications Specialties Inc All Rights Reserved Fiberlink and the starburst logo are registered trademarks of Communications Specialties Inc CSI and th...

Отзывы: