![FiberLabs OTM-1550L Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/fiberlabs/otm-1550l/otm-1550l_operating-manual_2286718015.webp)
Technical passport / OTM-1550
12-2016-v4
4.3.5 Connecting Power
The
OTM-1550L
is available in an AC220V power model. After mounting the
OTM-1550L
in a rack, follow the power connection procedure below for the model
that you are installing.
Can be equipped with two 220V power supply that requires input voltage 150
~
265VAC, at 50
~
60Hz single phase. The AC power plug is located on the rear panel.
Turn on the power source. It takes about 60 seconds for all systems to operate.
5. Communication Setup
5.1 RS232
Communication Interface Description
Adopt DB9 standard connector, the pin definitions as follow:
1: No Connect
2: TX
3: RX
4: No Connect
5: GND
6: No Connect
7: No Connect
8: No Connect
9: No Connect
The serial communication uses the standard NRZ form, 1 starts bit, 8 data bits, 1
stop bit and the baud rate is 38400.
5.2 Set up the Hyper Terminal
If you have not setup the Hyper Terminal in your Windows system, follow the steps:
Click “start menu
program
accessory
communication
Hyper Terminal”: