Setting

Description

1

the Dimmer saves its state before power failure.

0

the Dimmer 2 does not save the state before a power failure, it returns to off position

Parameter 10: Timer functionality (auto - off)

 
Size: 2 Byte, Default Value: 0

Setting

Description

0

Function disabled

1 - 32767

time to turn off measured in seconds (1s-9.1h)

Parameter 11: ALL ON/ALL OFF function

Parameter allows for activation/deactivation of Z-Wave commands enabling/disabling all devices located in direct range of the main controller. 

Size: 2 Byte, Default Value: 255

Setting

Description

0

ALL ON not active, ALL OFF not active

1

ALL ON not active, ALL OFF active

2

ALL ON active, ALL OFF not active

255

ALL ON active, ALL OFF active

Parameter 13: Force auto-calibration

Changing value of this parameter will force the calibration process. During the calibration parameter is set to 1 or 2 and switched to 0 upon completion. 

Size: 1 Byte, Default Value: 0

Setting

Description

0

readout

1

force auto-calibration of the load without FIBARO Bypass 2

2

force auto-calibration of the load with FIBARO Bypass 2

Parameter 14: Auto-calibration status

This parameter determines operating mode of the Dimmer 2 (automatic/manual settings). 

Size: 1 Byte, Default Value: 0

Setting

Description

0

calibration procedure not performed or Dimmer 2 operates on manual settings

1

Dimmer 2 operates on auto-calibration settings

Parameter 15: Burnt out bulb detection

Function based on the sudden power variation of a specific value, interpretedas a LOAD ERROR.
CAUTIONParameter 15 is relevant only when parameter 58 is set to 0 and the control modeis consistent with the mode set during the calibration process
(parameter 30). 

Size: 1 Byte, Default Value: 30

Setting

Description

0

function disabled

1 - 99

percentage value of power variation, compared to standard power consumption, measured during the
calibration procedure (to be interpreted as load error/burnt out bulb)

Parameter 16: Time delay of a burnt out bulb (parameter 15) or overload (parameter 39) detection

Time of delay (in seconds) for power variation detection, interpretedas a LOAD ERROR or OVERLOAD detection (too much power connectedto the Dimmer 2). 

Size: 2 Byte, Default Value: 5

Setting

Description

0

detection of a burnt out bulb disabled

1 - 255

delay time in seconds

Parameter 19: Forced switch on brightness level

If the parameter is active, switching on the Dimmer 2 (S1 single click)will always set this brightness level) 

Size: 1 Byte, Default Value: 0

Содержание Dimmer 2

Страница 1: ...in direct wireless range of the transmitter This device and every other certified Z Wave device can be used together with any other certified Z Wave device regardless of brand and origin as long as both are suited for the same frequency range If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of securit...

Страница 2: ...se the primary controller of the previous network to make sure the very device is excluded properly from this network Reset to factory default This device also allows to be reset without any involvement of a Z Wave controller This procedure should only be used when the primary controller is inoperable 1 Disconnect the power supply 2 Remove the Dimmer 2 from the wall switch box 3 Connect the power ...

Страница 3: ...ed to the S1 terminal is a master switch It activates the basic functionality of the Dimmer 2 turning the light on off dimming and starts the learning mode Add Remove The switch connected to the S2 terminal is an optional switch and pushing it without changing the configuration parameters will not affect the status of the device Functionality of the switches can be reversed by adjusting advanced p...

Страница 4: ...s called Exclusion Both processes are initiated by the primary controller of the Z Wave network This controller is turned into exclusion respective inclusion mode Inclusion and Exclusion is then performed doing a special manual action right on the device Inclusion Press three times the B button or key connected to the S1 terminal Exclusion Press three times the B button or key connected to the S1 ...

Страница 5: ...re a few hints for network installation if things dont work as expected 1 Make sure a device is in factory reset state before including In doubt exclude before include 2 If inclusion still fails check if both devices use the same frequency 3 Remove all dead devices from associations Otherwise you will see severe delays 4 Never use sleeping battery devices without a central controller 5 Dont poll F...

Страница 6: ...mmable compactfluorescent lamps and certain types of light sources Size 1 Byte Default Value 1 Setting Description 1 99 percentage level of brightness Parameter 4 Incandescence time of dimmable compact fluorescent lamps This parameter determines the time required for switching compactfluorescent lamps and certain types of light sources Setting this parameterto 0 will disable the incandescence func...

Страница 7: ...with FIBARO Bypass 2 Parameter 14 Auto calibration status This parameter determines operating mode of the Dimmer 2 automatic manual settings Size 1 Byte Default Value 0 Setting Description 0 calibration procedure not performed or Dimmer 2 operates on manual settings 1 Dimmer 2 operates on auto calibration settings Parameter 15 Burnt out bulb detection Function based on the sudden power variation o...

Страница 8: ...acts Size 1 Byte Default Value 0 Setting Description 0 Device changes status on key status change 1 Device status is synchronized with key status Parameter 23 Double click option Size 1 Byte Default Value 1 Setting Description 0 double click disabled 1 double click enabled Parameter 24 Command frames sent in 2 nd and 3 rd association groups S1 associations Parameter determines which actions will n...

Страница 9: ...e sent as secure Size 1 Byte Default Value 15 Setting Description 0 all groups II V sent as non secure 1 group 2 sent as secure 2 group 3 sent as secure 4 group 4 sent as secure 8 group 5 sent as secure 15 groups II V sent as secure Parameter 28 Scene activation functionality SCENE ID depends on the switch type configurations NOTE Enabling scene activation functionality may cause slight delay in r...

Страница 10: ... 35 Auto calibration after power on This parameter determines the trigger of auto calibration procedure e g power on load error etc Size 1 Byte Default Value 1 Setting Description 0 No auto calibration of the load after power on 1 Auto calibration performed after first power on 2 Auto calibration performed after each power on 3 Auto calibration performed after first power on or after each LOAD ERR...

Страница 11: ...Byte Default Value 3 Setting Description 0 No reaction 1 Turn on the load 2 Turn off the load 3 Load blinking Parameter 43 Response to Temperature Alarm Size 1 Byte Default Value 1 Setting Description 0 No reaction 1 Turn on the load 2 Turn off the load 3 Load blinking Parameter 44 Time of alarm state Size 2 Byte Default Value 600 Setting Description 1 32767 1s 32767s Parameter 45 OVERLOAD alarm r...

Страница 12: ...consecutive reports Timer is reset and counted from zero after each report Size 2 Byte Default Value 3600 Setting Description 0 periodic reports disabled 1 32767 1 32767 seconds Parameter 53 Energy reports Energy level change which will result in sending a new energy report Size 2 Byte Default Value 10 Setting Description 0 energy reports disabled 1 255 0 01 2 55 kWh report triggering threshold Pa...

Страница 13: ...ghtness level Technical Data Dimensions 42 x 38 x 20 mm Weight 28 gr Hardware Platform ZM5202 EAN 5902020528524 IP Class IP IP20 Voltage 100 240V Load 250 W Device Type Light Dimmer Switch Network Operation Always On Slave Z Wave Version 6 51 06 Certification ID ZC10 16045036 Z Wave Product Id 0x010F 0x0102 0x1000 Frequency Europe 868 4 Mhz Maximum transmission power 5 mW Supported Command Classes...

Страница 14: ... one primary controller in a Z Wave network Inclusion is the process of adding new Z Wave devices into a network Exclusion is the process of removing Z Wave devices from the network Association is a control relationship between a controlling device and a controlled device Wakeup Notification is a special wireless message issued by a Z Wave device to announces that is able to communicate Node Infor...

Отзывы: