Setting
Description
1
the Dimmer saves its state before power failure.
0
the Dimmer 2 does not save the state before a power failure, it returns to off position
Parameter 10: Timer functionality (auto - off)
Size: 2 Byte, Default Value: 0
Setting
Description
0
Function disabled
1 - 32767
time to turn off measured in seconds (1s-9.1h)
Parameter 11: ALL ON/ALL OFF function
Parameter allows for activation/deactivation of Z-Wave commands enabling/disabling all devices located in direct range of the main controller.
Size: 2 Byte, Default Value: 255
Setting
Description
0
ALL ON not active, ALL OFF not active
1
ALL ON not active, ALL OFF active
2
ALL ON active, ALL OFF not active
255
ALL ON active, ALL OFF active
Parameter 13: Force auto-calibration
Changing value of this parameter will force the calibration process. During the calibration parameter is set to 1 or 2 and switched to 0 upon completion.
Size: 1 Byte, Default Value: 0
Setting
Description
0
readout
1
force auto-calibration of the load without FIBARO Bypass 2
2
force auto-calibration of the load with FIBARO Bypass 2
Parameter 14: Auto-calibration status
This parameter determines operating mode of the Dimmer 2 (automatic/manual settings).
Size: 1 Byte, Default Value: 0
Setting
Description
0
calibration procedure not performed or Dimmer 2 operates on manual settings
1
Dimmer 2 operates on auto-calibration settings
Parameter 15: Burnt out bulb detection
Function based on the sudden power variation of a specific value, interpretedas a LOAD ERROR.
CAUTIONParameter 15 is relevant only when parameter 58 is set to 0 and the control modeis consistent with the mode set during the calibration process
(parameter 30).
Size: 1 Byte, Default Value: 30
Setting
Description
0
function disabled
1 - 99
percentage value of power variation, compared to standard power consumption, measured during the
calibration procedure (to be interpreted as load error/burnt out bulb)
Parameter 16: Time delay of a burnt out bulb (parameter 15) or overload (parameter 39) detection
Time of delay (in seconds) for power variation detection, interpretedas a LOAD ERROR or OVERLOAD detection (too much power connectedto the Dimmer 2).
Size: 2 Byte, Default Value: 5
Setting
Description
0
detection of a burnt out bulb disabled
1 - 255
delay time in seconds
Parameter 19: Forced switch on brightness level
If the parameter is active, switching on the Dimmer 2 (S1 single click)will always set this brightness level)
Size: 1 Byte, Default Value: 0