background image

Display for linear measurement

SIMPLEX-E

Data: 13/01/16

file: Simplex_ing.doc

pag 4/8

Count direction  

%.+

%.+

%.+

%.+

Set out the count direction of the display, range allowed 0 or 1.
Setting 0 the value on the display increases, turning the hollow shaft clockwise.
Setting 1 the value on the display decreases, turning the hollow shaft clockwise.

Keys opening mode

 

//

//

//

//

This parameter programmes the functions linked to the keys.
The value to set is a number of three digits so each key corresponds to a digit; the digit on the right stands for
setting of key 

RESET

, the digit in the middle stands for key   while the last digit on the left stand for key 

 .

The values allowed are the following:

VALUE

KEY   

KEY   

KEY  

RESET

0

Not open

Not open

Not open

1

Function

 ABS

/

REL

Conversion mm/inch

Reset

2

Not open

Display  in degrees

Preset

3

Not open

Not open

Fast Preset

4

Not open

Not open

Change of origin 0,1,2

Reset: 

function

 

of reset of quota, pressing on key 

RESET

 the quota is zero-set .

Preset:

 function of preset of quota, pressing on key 

RESET

 the quota on the display became the same of the

one set in parameter Preset. The setting of Preset value appears immediately after parameter 

//

//

//

//

 (if

chose value 2).

Fast

 

Preset: 

the fast setting of the quota on the display, pressing on key 

RESET

 appears Preset and pressing

still 2 times 

RESET

 is possible to set the value directly (use keys        

  and confirm with 

RESET

). This

function  is useful when the quote on the display has often be corrected.

Origin change 

(quota correction for tool change): with this function 3 different origins (0,1,2) are

programmable  and passes from an origin to the other wit key 

RESET

. Activating the function of origin change

on the display appear two small arrows  and the indication of the selected origin  happens with the switching
on of the origin indicators (see paragraph meaning of symbols ). After setting 4 in the first digit on the right of

//

//

//

//

, will appear PrS0 and pressing 2 times 

RESET

 has to be set the value to be read in this position of

shaft for origin 0, confirm with 

RESET

. It will appear PrS1 which is the value to be read for origin 1 in the

present position of shaft: set the correct value and confirm with 

RESET

. It will appears PrS2  which is the value

to be read for origin 2 in the present position of shaft: set the correct value and confirm with 

RESET

. It means

PrS0, PrS1, PrS2 are references for the calibration, in a certain position of the shaft, in three different origins.

Function 

ABS

/

REL

:

 

Enables the pass from absolute to relative value, pressing key 

  zero-set temporary the

value to allow a relative shifting. On the display switches on indicator REL to indicate that the  current quote is
relative to the zero-point just created. Pressing still key 

 reappears the absolute value and on the display

switches on the indicator ABS.

Conversion mm/inch:

 Pressing key  converts the measure from millimetre to inches and back with

indication of inch/mm on the display and a decimal number more then for millimetres.  By choosing 5
decimals for millimetres the conversion in inches is not allowed.

Visualization in degrees: 

Pressing on key    on the display appears Deg to indicate the visualization of

measure in degrees.

Origin displacement    

,/

,/

,/

,/

This parameter is added or subtracted from the current quota to correct the value showed on the display, for
example following wear or changing of tool. Setting a positive value on display appears the current quota added
to this value.
Set zero to exclude the offset function (manufacturer’s value).
The offset is not available if the function of tool-change is selected.

Содержание SIMPLEX-E Series

Страница 1: ...Display for linear measurement SIMPLEX E Data 13 01 16 file Simplex_ing doc pag 1 8 USER S MANUAL AND MAINTENANCE ELECTRONIC DISPLAY FOR LINEAR MEASUREMENT WITH BATTERY OPERATED ...

Страница 2: ...ose exposed to bad weather avoid open areas Avoid putting the instrument directly on the ground Store the instrument in its original packing Conformity declaration and EC marking The instrument answers to the following Communitarian Directives 2014 30 EU Electromagnetic compatibility 2011 65 EU RoHS Maintenance The instrument does not needs a particular maintenance except cleaning to do only with ...

Страница 3: ...kaging wood aluminium sheet working silk screen printing etc Available version with serial output RS485 with MODBUS RTU protocol and power supply 24Vdc and inner rechargeable battery 5 months functioning without power supply for connection with remote units Programming To step into the parameter programming press key and on the display appears now press 2 times key RESET and appear 4 zeroes the fi...

Страница 4: ...ear two small arrows and the indication of the selected origin happens with the switching on of the origin indicators see paragraph meaning of symbols After setting 4 in the first digit on the right of will appear PrS0 and pressing 2 times RESET has to be set the value to be read in this position of shaft for origin 0 confirm with RESET It will appear PrS1 which is the value to be read for origin ...

Страница 5: ...e instrument is supplied with 2 batteries type AA of 1 5V alkaline type which assures a functioning of about 1 year When the loading level goes under a certain value the indicator of flat battery begins to blink in occasional way and when it keeps switched on its necessary to change the batteries within a month To enter into the battery holder its necessary to take off the cover and screw off the ...

Страница 6: ...rees 7 Indicator of positive Offset indicates that the measure is corrected by a positive offset 8 Indicator of negative Offset indicates that the measure is corrected by a negative offset 9 Indicator of values changing it blinks during the programming phase 10 Indicator of origins indicates that the origin changing mode is opened 11 Indicator for origin 1 12 Indicator for origin 2 Erros messages ...

Страница 7: ... 505 00 705 00 Guidance lengh t 180 230 330 430 630 830 Fori Ø4 2 di bloccaggio strumento Bores Ø4 2 for instrument fixing Bohrungen Ø4 2 für Gerät Befestigung Banda magnetica Magnetic tape Magnet Band Limitatori di corsa Stroke limiting device Hubbegrenzer Guida scorrevole Sliding guidance Führungsschiene Rialzo per guida Height for guidance Führungserhebung 62 74 25 Ø4 1 Ø4 2 L 25 7 5 38 12 5 2 ...

Страница 8: ...and balancing of tool wear Measure bar Anodized aluminium Box Strengthen polyamide glass oil fat proof Protection degree IP54 optional IP65 Working temperature 0 50 C Relative humidity 30 90 Directive 2014 30 EU Electromagnetic compatibility 2011 65 EU RoHS Manufacturer All communications to the manufacturer should be addressed to FIAMA s r l Via G Di Vittorio 5 A 43016 San Pancrazio Parma Italy T...

Отзывы: